CoChat

Efficacy and Safety of Low-field Synchronized Transcranial Magnetic Stimulation (sTMS) for Treatment of Major Depression

Open access
Leuchter, Andrew F., Cook, Ian A., Feifel, David, Goethe, John W., Husain, Mustafa, Carpenter, Linda L., Thase, Michael E., Krystal, Andrew D., Philip, Noah S., Bhati, Mahendra T., Burke, William J., Howland, Robert H., Sheline, Yvette I., Aaronson, Scott T., Iosifescu, Dan V., O'Reardon, John P., Gilmer, William S., Jain, Rakesh, Burgoyne, Karl S., Phillips, Bill, Manberg, Paul J., Massaro, Joseph, Hunter, Aimee M., Lisanby, Sarah H., George, Mark S. · 2015 · Brain Stimulation
Cited by 137

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

BACKGROUND Transcranial Magnetic Stimulation (TMS) customarily uses high-field electromagnets to achieve therapeutic efficacy in Major Depressive Disorder (MDD). Low-field magnetic stimulation also may be useful for treatment of MDD, with fewer treatment-emergent adverse events. OBJECTIVE/HYPOTHESIS To examine efficacy, safety, and tolerability of low-field magnetic stimulation synchronized to an individual's alpha frequency (IAF) (synchronized TMS, or sTMS) for treatment of MDD. METHODS Six-week double-blind sham-controlled treatment trial of a novel device that used three rotating neodymium magnets to deliver sTMS treatment. IAF was determined from a single-channel EEG prior to first treatment. Subjects had baseline 17-item Hamilton Depression Rating Scale (HamD17) ≥ 17. RESULTS 202 subjects comprised the intent-to-treat (ITT) sample, and 120 subjects completed treatment per-protocol (PP). There was no difference in efficacy between active and sham in the ITT sample. Subjects in the PP sample (N = 59), however, had significantly greater mean decrease in HamD17 than sham (N = 60) (-9.00 vs. -6.56, P = 0.033). PP subjects with a history of poor response or intolerance to medication showed greater improvement with sTMS than did treatment-naïve subjects (-8.58 vs. -4.25, P = 0.017). Efficacy in the PP sample reflects exclusion of subjects who received fewer than 80% of scheduled treatments or were inadvertently treated at the incorrect IAF; these subgroups failed to separate from sham. There was no difference in adverse events between sTMS and sham, and no serious adverse events attributable to sTMS. CONCLUSIONS Results suggest that sTMS may be effective, safe, and well tolerated for treating MDD when administered as intended.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.brs.2015.05.005

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 137

Metadata

Authors
Leuchter, A. F., Cook, I. A., Feifel, D., Goethe, J. W., Husain, M., Carpenter, L. L., Thase, M. E., Krystal, A. D., Philip, N. S., Bhati, M. T., Burke, W. J., Howland, R. H., Sheline, Y. I., Aaronson, S. T., Iosifescu, D. V., O'Reardon, J. P., Gilmer, W. S., Jain, R., Burgoyne, K. S., Phillips, B., Manberg, P. J., Massaro, J., Hunter, A. M., Lisanby, S. H., & George, M. S.
Venue
Brain Stimulation
Publisher
Elsevier BV
Published
2015-07
Volume
8
Issue
4
Pages
787-794
ISSN
  • 1876-4754 (ISSN-L)
  • 1935-861X
OpenAlex
W2136495405
Cited by
137
References
13
FWCI
5.36
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.