The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Cuffless blood pressure estimation from electrocardiogram and photoplethysmogram using waveform based ANN-LSTM network
Open accessAbstract
Goal: Although photoplethysmogram (PPG) and electrocardiogram (ECG) signals can be used to estimate blood pressure (BP) by extracting various features, the changes in morphological contours of both PPG and ECG signals due to various diseases of circulatory system and interaction of other physiological systems make the extraction of such features very difficult. Methods: In this work, we propose a waveform-based hierarchical Artificial Neural Network - Long Short Term Memory (ANN-LSTM) model for BP estimation. The model consists of two hierarchy levels, where the lower hierarchy level uses ANNs to extract necessary morphological features from ECG and PPG waveforms and the upper hierarchy level uses LSTM layers to account for the time domain variation of the features extracted by lower hierarchy level. Results: The proposed model is evaluated on 39 subjects using the Association for the Advancement of Medical Instrumentations (AAMI) standard and the British Hypertension Society (BHS) standard. The method satisfies both the standards in the estimation of systolic blood pressure (SBP) and diastolic blood pressure (DBP). For the proposed network, the mean absolute error (MAE) and the root mean square error (RMSE) for SBP estimation are 1.10 and 1.56 mmHg, respectively, and for DBP estimation are 0.58 and 0.85 mmHg, respectively. Conclusion: The performance of the proposed hierarchical ANN-LSTM model is found to be better than the other feature engineering-based networks. It is shown that the proposed model is able to automatically extract the necessary features and their time domain variations to estimate BP reliably in a noninvasive continuous manner. Significance: The method is expected to greatly facilitate the presently available mobile health-care gadgets in continuous BP estimation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hochreiter, S., & Schmidhuber, J. (1997) · Neural Computation · doi:10.1162/neco.1997.9.8.1735 · Cited by 102,318
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Bidirectional recurrent neural networks
Schuster, M., & Paliwal, K. K. (1997) · IEEE Transactions on Signal Processing · doi:10.1109/78.650093 · Cited by 10,172 · cited 1×
“The first LSTM layer is made bidirectional [41] to model the time variations in both directions.”
Rothwell, P. M., Howard, S. C., Dolan, E., O'Brien, E., Dobson, J. E., Dahlöf, B., Sever, P. S., & Poulter, N. R. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60308-x · Cited by 1,784 · cited 1×
“In recent studies, high blood pressure variability has been shown to be a significant predictor for stroke [5].”
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206 · cited 2×
“Other than PTT, many other morphological features, that can be extracted from PPG signals, have also been found to be correlated with blood pressure [12].”
BackgroundThe Autonomic Nervous System and Hypertension
Mancia, G., & Grassi, G. (2014) · Circulation Research · doi:10.1161/circresaha.114.302524 · Cited by 627
Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring
Kachuee, M., Kiani, M. M., Mohammadzade, H., & Shabany, M. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2580904 · Cited by 621 · cited 2×
“In recent years, Kachuee et al. [13] and Xu et al. [14] have used PTT as the main feature along with many other parameters extracted from PPG signals as auxiliary features and have used machine learning algorithms to obtain models with better accuracy and more promising results than PTT-only models…”
MethodGuideline for the diagnosis and management of hypertension in adults - 2016
Gabb, G. M., Mangoni, A. A., Anderson, C. S., Cowley, D., Dowden, J. S., Golledge, J., Hankey, G. J., Howes, F. S., Leckie, L., Perkovic, V., et al. (2016) · Medical Journal of Australia · doi:10.5694/mja16.00526 · Cited by 406
Charlton, P. H., Bonnici, T., Tarassenko, L., Clifton, D. A., Beale, R., & Watkinson, P. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/610 · Cited by 366 · cited 1×
“As the arterial pressure of the human body is regulated by the autonomic nervous system and renal-body fluid mechanism that involve multiple feedback control loops [20], [21], its effects can also be seen in the ECG and PPG signals as modulations [22].”
Background
Cited by
El-Hajj, C., & Kyriacou, P. A. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.101870 · Cited by 294
Cuffless Blood Pressure Monitoring: Promises and Challenges
Pandit, J. A., Lores, E., & Batlle, D. (2020) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03680320 · Cited by 101
Metadata
- Authors
- Tanveer, M. S., & Hasan, M. K.
- Venue
- Biomedical Signal Processing and Control
- Publisher
- Elsevier BV
- Published
- 2019-05
- Volume
- 51
- Pages
- 382-392
- ISSN
- 1746-8094 (ISSN-L)
- OpenAlex
- W2900241252
- Cited by
- 188
- References
- 13
- FWCI
- 8.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cuffless blood pressure estimation from electrocardiogram and photoplethysmogram using waveform based ANN-LSTM network. https://app.cochat.ai/papers/10.1016/j.bspc.2019.02.028
- The paper
- Tanveer, M. S., & Hasan, M. K. (2019). Cuffless blood pressure estimation from electrocardiogram and photoplethysmogram using waveform based ANN-LSTM network. Biomedical Signal Processing and Control. https://doi.org/10.1016/j.bspc.2019.02.028
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.