Thermal comfort evaluated for combinations of energy-efficient personal heating and cooling devices
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Abstract Personal comfort systems (PCS) have potential to fulfill building occupants' personal thermal comfort preferences with great efficiency. But to integrate them into building conditioning, there must be a broader selection of PCS devices available. Design guidance and standards are needed to assure that such devices provide high levels of comfort effectiveness and energy efficiency. This study addresses these needs. A suite of minimum-power PCS devices was built that target body parts significant to alliesthesia—a heated shoe insole, heated/cooled wristpad, small deskfan, and heated/cooled chair. They were tested in a climate chamber under cool and warm conditions using both thermal-manikin and human-subjects. Their efficiency at physically heating/cooling the body is high; the combined suite has a coefficient of performance (COP) of 3.6 for cooling and 0.88 for heating. The subjects' whole-body thermal acceptance and thermal comfort perception were improved by the devices in an additive manner; using the combined suite over 80% of people accepted ambient temperatures of 18°C and 29°C. The PCS ‘corrects’ the ambient temperature towards thermal neutrality by as much as 6.5 K cooling and 3.6 K heating, overcoming building occupants' typical interpersonal thermal differences and making possible large HVAC energy savings in buildings. The idea of temperature corrective power can be the basis of standards for PCS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Individual difference in thermal comfort: A literature review
Wang, Z., de Dear, R., Luo, M., Lin, B., He, Y., Ghahramani, A., & Zhu, Y. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.04.040 · Cited by 675
Self-citationHoyt, T., Arens, E., & Zhang, H. (2015) · Building and Environment · doi:10.1016/j.buildenv.2014.09.010 · Cited by 607 · cited 2×
“[4], indicating savings in total annual HVAC energy consumption caused by widening the temperature deadband of the HVAC system.”
BackgroundSelf-citationThermal comfort and gender: a literature review
Karjalainen, S. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2011.00747.x · Cited by 536 · cited 1×
“These differences arise from: a) the inter-personal variance among people [39] (attributed to factors such as gender [40], body mass [41], age [42], dress custom, and activity level [43], and b) the intra-personal variation in thermal perceptions of a single person over time.”
BackgroundPersonalized conditioning and its impact on thermal comfort and energy performance – A review
Veselý, M., & Zeiler, W. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.03.024 · Cited by 322 · cited 2×
“A literature review by Vesely and Zeiler [19] found that personalized heating/cooling devices maintaining thermal comfort at ambient temperatures 4– 5K higher or lower than those recommended in current standards.”
BackgroundThermal pleasure in built environments: physiology of alliesthesia
Parkinson, T., & de Dear, R. (2015) · Building Research & Information · doi:10.1080/09613218.2015.989662 · Cited by 263 · cited 1×
“Second, ‘spatial alliesthesia’ refers to effects of non-neutral thermal conditions occurring on various body parts at the same time [13,14,15].”
BackgroundHuman metabolic rate and thermal comfort in buildings: The problem and challenge
Luo, M., Wang, Z., Ke, K., Cao, B., Zhai, Y., & Zhou, X. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.01.005 · Cited by 231 · cited 1×
“These differences arise from: a) the inter-personal variance among people [39] (attributed to factors such as gender [40], body mass [41], age [42], dress custom, and activity level [43], and b) the intra-personal variation in thermal perceptions of a single person over time.”
BackgroundSelf-citationComfort under personally controlled air movement in warm and humid environments
Zhai, Y., Zhang, H., Zhang, Y., Pasut, W., Arens, E., & Meng, Q. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.03.022 · Cited by 231 · cited 2×
“A warm face and breathing zone is perceived as uncomfortable in neutral and warm ambient conditions, and a small area of air movement in the head/neck region has an outsized effect on thermal comfort [28][29].”
BackgroundMethodSelf-citationThermal pleasure in built environments: alliesthesia in different thermoregulatory zones
Parkinson, T., de Dear, R., & Candido, C. (2016) · Building Research & Information · doi:10.1080/09613218.2015.1059653 · Cited by 126
Cited by
Luo, M., Xie, J., Yan, Y., Ke, Z., Yu, P., Wang, Z., & Zhang, J. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.109776 · Cited by 227
Self-citationRevisiting individual and group differences in thermal comfort based on ASHRAE database
Wang, Z., Zhang, H., He, Y., Luo, M., Li, Z., Hong, T., & Lin, B. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110017 · Cited by 123
Self-citation
Metadata
- Authors
- Luo, M., Arens, E., Zhang, H., Ghahramani, A., & Wang, Z.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2018-10
- Volume
- 143
- Pages
- 206-216
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W2817357254
- Cited by
- 166
- References
- 8
- FWCI
- 10.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.