The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Role of oxygen functional groups in graphene oxide for reversible room-temperature NO2 sensing
Abstract
Abstract Reduced graphene oxide (rGO) is one of the promising sensing elements for high-performance chemoresistive sensors because of its remarkable advantages such as high surface-to-volume ratio, outstanding transparency, and flexibility. In addition, the defects on the surface of rGO, including oxygen functional groups, can act as active sites for interaction with gaseous molecules. However, the major drawback of rGO-based sensors is the extremely sluggish and irreversible recovery to the initial state after a sensing event, which makes them incapable of producing repeatable and reliable sensing signals. Here, we show that pristine GO can be used as the active sensing material with reversible and high response to NO 2 at room temperature. First-principles calculations, in conjunction with experimental results, reveal the critical role of hydroxyl groups rather than epoxy groups in changing metallic graphene to the semiconducting GO. We show that the adaptive motions of the hydroxyl groups, that is, the rotation of these groups for the adsorption of NO 2 molecules and relaxation to the original states during the desorption of NO 2 molecules, are responsible for the fast and reversible NO 2 sensing behavior of GO. Our work paves the way for realizing high-response, reversible graphene-based room-temperature chemoresistive sensors for further functional convergence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Graphene: Status and Prospects
Geim, A. K. (2009) · Science · doi:10.1126/science.1158877 · Cited by 13,942
Cited by
Room Temperature Gas Sensing of Two-Dimensional Titanium Carbide (MXene)
Lee, E., VahidMohammadi, A., Prorok, B. C., Yoon, Y. S., Beidaghi, M., & Kim, D.-J. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b11055 · Cited by 878
Self-citationRoom-Temperature, Highly Durable Ti3C2Tx MXene/Graphene Hybrid Fibers for NH3 Gas Sensing
Lee, S. H., Eom, W., Shin, H., Ambade, R. B., Bang, J. H., Kim, H. W., & Han, T. H. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b21765 · Cited by 435
Recent Advances in Emerging 2D Material‐Based Gas Sensors: Potential in Disease Diagnosis
Zhang, L., Khan, K., Zou, J., Zhang, H., & Li, Y. (2019) · Advanced Materials Interfaces · doi:10.1002/admi.201901329 · Cited by 281
Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors.
Luo, Y., Li, J., Ding, Q., Wang, H., Liu, C., & Wu, J. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01109-2 · Cited by 236
“…oxygen-containing functional groups such as − OH, SO 3− and − NH 2 play a non-negligible role in promoting the adsorption of NO 2 and NH 3 molecules, so functionalized hydrogels such as PVA and PAM rich in oxygen-containing groups are also commonly used in the preparation of gas sensors [221, 222].”
BackgroundWu, J., Wu, Z., Han, S., Yang, B.-R., Gui, X., Tao, K., Liu, C., Miao, J., & Norford, L. K. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b17437 · Cited by 225
Metadata
- Authors
- Choi, Y. R., Yoon, Y.-G., Choi, K. S., Kang, J. H., Shim, Y.-S., Kim, Y. H., Chang, H. J., Lee, J.-H., Park, C. R., Kim, S. Y., & Jang, H. W.
- Venue
- Carbon
- Publisher
- Elsevier BV
- Published
- 2015-09
- Volume
- 91
- Pages
- 178-187
- ISSN
- 0008-6223 (ISSN-L)
- OpenAlex
- W2062422613
- Cited by
- 233
- References
- 1
- FWCI
- 9.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Role of oxygen functional groups in graphene oxide for reversible room-temperature NO2 sensing. https://app.cochat.ai/papers/10.1016/j.carbon.2015.04.082
- The paper
- Choi, Y. R., Yoon, Y.-G., Choi, K. S., Kang, J. H., Shim, Y.-S., Kim, Y. H., Chang, H. J., Lee, J.-H., Park, C. R., Kim, S. Y., & Jang, H. W. (2015). Role of oxygen functional groups in graphene oxide for reversible room-temperature NO2 sensing. Carbon. https://doi.org/10.1016/j.carbon.2015.04.082
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.