A pilot study: Subclinical hypothyroidism and free thyroid hormone measurement by immunoassay and mass spectrometry
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Background The diagnosis of subclinical hypothyroidism is defined as the presence of an elevated thyroid stimulating hormone (TSH) with a normal free thyroxine (FT4) level. The commonly used direct analogue immunoassays for the measurement of FT4 have been shown to have poor performance at the upper and lower limits of the FT4 reference interval. Purpose The purpose of this pilot study was to investigate the percentage of individuals classified as having subclinical hypothyroidism with a standard immunoassay, that actually have low free thyroid hormone levels by mass spectrometry measurements. Design Outpatient samples with elevated TSH values and normal FT4 concentrations as per standard immunoassay methods were collected. FT4 and free triiodothyronine (FT3) analyses were performed on these samples using liquid chromatography–tandem mass spectrometry (LC-MS/MS). Results Sixty five percent (n=26) of patients (n=40) had (LC-MS/MS) FT4 or FT3 or both FT4 and FT3 values below mass spectrometry reference limits. Conclusions Our findings indicate that the direct analogue immunoassay method for FT4 measurement results in a significant proportion of patients being misclassified as having subclinical hypothyroidism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Colorado Thyroid Disease Prevalence Study
Canaris, G. J., Manowitz, N. R., Mayor, G., & Ridgway, E. C. (2000) · Archives of Internal Medicine · doi:10.1001/archinte.160.4.526 · Cited by 2,824 · cited 1×
“The prevalence of subclinical hypothyroidism in the population without known thyroid disease has been reported to be 4% to 10% [2,3].”
BackgroundLaboratory Support for the Diagnosis and Monitoring of Thyroid Disease
(2003) · Thyroid · doi:10.1089/105072503321086962 · Cited by 1,212
Gharib, H., Tuttle, R. M., Baskin, H. J., Fish, L. H., Singer, P. A., & McDermott, M. T. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2004-1231 · Cited by 394
van Deventer, H. E., Mendu, D. R., Remaley, A. T., & Soldin, S. J. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.154088 · Cited by 108
Self-citationTractenberg, R. E., Jonklaas, J., & Soldin, S. J. (2010) · International Journal of Analytical Chemistry · doi:10.1155/2010/234808 · Cited by 64
Self-citation
Cited by
DIAGNOSIS OF ENDOCRINE DISEASE: How reliable are free thyroid and total T3 hormone assays?
Welsh, K. J., & Soldin, S. J. (2016) · European Journal of Endocrinology · doi:10.1530/eje-16-0193 · Cited by 124
Self-citationVariability in the detection of macro TSH in different immunoassay systems
Hattori, N., Ishihara, T., & Shimatsu, A. (2016) · European Journal of Endocrinology · doi:10.1530/eje-15-0883 · Cited by 57
Bowerbank, S. L., Carlin, M. G., & Dean, J. R. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-01724-2 · Cited by 38
Masika, L. S., Zhao, Z., & Soldin, S. J. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.02.004 · Cited by 23
“For example, in the low range, IAs give false normal results in about 50% of FT3 and TT3 and 65% of FT4 results [4,6,8,9,15].”
BackgroundSelf-citationWelsh, K. J., Stolze, B. R., Yu, X., Podsiadlo, T. R., Kim, L. S., & Soldin, S. J. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.11.022 · Cited by 17
Self-citation
Metadata
- Authors
- Gounden, V., Jonklaas, J., & Soldin, S. J.
- Venue
- Clinica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2014-03
- Volume
- 430
- Pages
- 121-124
- ISSN
- 0009-8981 (ISSN-L)
- OpenAlex
- W2023568556
- Cited by
- 30
- References
- 5
- FWCI
- 2.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.