Diversiform metal oxide-based hybrid nanostructures for gas sensing with versatile prospects
The DOI matches its Crossref record; 118 of the 118 references it cites were found in a registry or an index.
Abstract
Abstract Metal oxide semiconductors (MOS) have attracted much attention in constructing various gas sensors because of their low cost, portability, easy to manufacture, and high sensitivity. In this review, the gas-sensing mechanism of the MOS-based gas sensor and the factors affecting the gas sensitivity are summarized, in which the light excitation provides a promising potential to enhance the sensitivity of MOS-based gas sensors. This review focuses on providing various strategies to enhance their gas-sensing performance by specific functionalization of MOS with various materials such as metal oxides, metal nanoparticles (NPs), two-dimensional (2D) materials, conductive polymers, etc. We also discussed the metal-organic frameworks (MOFs)-derived MOS render them as an excellent gas-sensing material in detail, the MOS@MOFs nanostructures are able to effectively improve the selectivity of MOS sensors due to the adjustable pore size of MOFs. In addition, as an emerging application, wearable gas sensors are increasingly used in environmental monitoring and medical diagnosis. Electronic nose (E-nose), as an intelligent electronic instrument for distinguishing and identifying various odors, is introduced for the multi-component analysis. Self-powered gas sensing technologies have been developed by coupling piezoelectric or triboelectric devices with MOS-based sensors. Furthermore, the perspectives and challenges on the MOS-based sensors are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
Flexible triboelectric generator
Fan, F.-R., Tian, Z.-Q., & Lin Wang, Z. (2012) · Nano Energy · doi:10.1016/j.nanoen.2012.01.004 · Cited by 6,705
Nanoscale metal oxide-based heterojunctions for gas sensing: A review
Miller, D. R., Akbar, S. A., & Morris, P. A. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.07.074 · Cited by 1,852
Metallic Ti3C2T x MXene Gas Sensors with Ultrahigh Signal-to-Noise Ratio
Kim, S. J., Koh, H.-J., Ren, C. E., Kwon, O., Maleski, K., Cho, S.-Y., Anasori, B., Kim, C.-K., Choi, Y.-K., Kim, J., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07460 · Cited by 1,699
Salunkhe, R. R., Kaneti, Y. V., & Yamauchi, Y. (2017) · ACS Nano · doi:10.1021/acsnano.7b02796 · Cited by 1,279
Xu, X., Cao, R., Jeong, S., & Cho, J. (2012) · Nano Letters · doi:10.1021/nl302618s · Cited by 914
Two‐Dimensional Nanostructured Materials for Gas Sensing
Liu, X., Ma, T., Pinna, N., & Zhang, J. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201702168 · Cited by 851
Ultrahigh sensitivity and layer-dependent sensing performance of phosphorene-based gas sensors
Cui, S., Pu, H., Wells, S. A., Wen, Z., Mao, S., Chang, J., Hersam, M. C., & Chen, J. (2015) · Nature Communications · doi:10.1038/ncomms9632 · Cited by 763
Graphene–metal oxide nanohybrids for toxic gas sensor: A review
Gupta Chatterjee, S., Chatterjee, S., Ray, A. K., & Chakraborty, A. K. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.07.070 · Cited by 737
Breath analysis by nanostructured metal oxides as chemo-resistive gas sensors
Righettoni, M., Amann, A., & Pratsinis, S. E. (2015) · Materials Today · doi:10.1016/j.mattod.2014.08.017 · Cited by 487
Cited by
Wang, D., Zhang, D., Yang, Y., Mi, Q., Zhang, J., & Yu, L. (2021) · ACS Nano · doi:10.1021/acsnano.0c09015 · Cited by 687
Self-citationSemiconductor Gas Sensors: Materials, Technology, Design, and Application
Nikolic, M. V., Milovanovic, V., Vasiljevic, Z. Z., & Stamenkovic, Z. (2020) · Sensors · doi:10.3390/s20226694 · Cited by 590
Advances in Noble Metal-Decorated Metal Oxide Nanomaterials for Chemiresistive Gas Sensors: Overview
Zhu, L.-Y., Ou, L.-X., Mao, L.-W., Wu, X.-Y., Liu, Y.-P., & Lu, H.-L. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01047-z · Cited by 553
Zhang, D., Yu, S., Wang, X., Huang, J., Pan, W., Zhang, J., Meteku, B. E., & Zeng, J. (2022) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.127160 · Cited by 424
Self-citationWang, D., Zhang, D., Guo, J., Hu, Y., Yang, Y., Sun, T., Zhang, H., & Liu, X. (2021) · Nano Energy · doi:10.1016/j.nanoen.2021.106410 · Cited by 359
Self-citationZhang, C., Liu, G., Geng, X., Wu, K., & Debliquy, M. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2020.112026 · Cited by 297
Metal oxide semiconductors for gas sensing
Goel, N., Kunal, K., Kushwaha, A., & Kumar, M. (2023) · Engineering Reports · doi:10.1002/eng2.12604 · Cited by 294
Emerging van der Waals junctions based on TMDs materials for advanced gas sensors
Zheng, W., Liu, X., Xie, J., Lu, G., & Zhang, J. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214151 · Cited by 254
Advances of nanomaterials for air pollution remediation and their impacts on the environment
Saleem, H., Zaidi, S. J., Ismail, A. F., & Goh, P. S. (2022) · Chemosphere · doi:10.1016/j.chemosphere.2021.132083 · Cited by 167
Breath VOC analysis and machine learning approaches for disease screening: a review
P, H., Rangarajan, M., & Pandya, H. J. (2023) · Journal of Breath Research · doi:10.1088/1752-7163/acb283 · Cited by 37
“Recent research trends in designing sensing materials for chemiresistive gas sensors involve MOS based sensors along with multiple strategies to enhance their performance like functionalization with different materials like metal nanoparticles (NPs), conducting polymers (CPs), metal-organic frameworks, and 2D material…”
Metadata
- Authors
- Zhang, D., Yang, Z., Yu, S., Mi, Q., & Pan, Q.
- Venue
- Coordination Chemistry Reviews
- Publisher
- Elsevier BV
- Published
- 2020-06
- Volume
- 413
- Pages
- 213272
- ISSN
- 0010-8545 (ISSN-L)
- OpenAlex
- W3013455731
- Cited by
- 347
- References
- 118
- FWCI
- 15.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.