The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Breath analysis by nanostructured metal oxides as chemo-resistive gas sensors
Open accessAbstract
Recently breath analysis has attracted a lot of attention for disease monitoring and clinical diagnostics as spectrometric techniques of high sophistication and novel sensing materials become available. Here advances in these technologies in connection to breath analysis are critically reviewed. A number of breath markers or tracer compounds are summarized and related to different diseases, either for diagnostics or for monitoring. Emphasis is placed on chemo-resistive gas sensors for their low cost and portability highlighting their potential and challenges for breath analysis as they start to be used in studies involving humans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standards of medical care in diabetes—2013
American Diabetes Association (2013) · Diabetes Care · doi:10.2337/dc13-s011 · Cited by 4,369
Dweik, R. A., Boggs, P. B., Erzurum, S. C., Irvin, C. G., Leigh, M. W., Lundberg, J. O., Olin, A.-C., Plummer, A. L., & Taylor, D. R. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.9120-11st · Cited by 2,539
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Self-citationQuantitative analysis of ammonia on the breath of patients in end-stage renal failure
Davies, S., Spanel, P., & Smith, D. (1997) · Kidney International · doi:10.1038/ki.1997.324 · Cited by 406
Turner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379
Cited by
Semiconductor metal oxide gas sensors: A review
Dey, A. (2018) · Materials Science and Engineering: B · doi:10.1016/j.mseb.2017.12.036 · Cited by 2,374
First Fifty Years of Chemoresistive Gas Sensors
Neri, G. (2015) · Chemosensors · doi:10.3390/chemosensors3010001 · Cited by 530
Self‐Powered Respiration Monitoring Enabled By a Triboelectric Nanogenerator
Su, Y., Chen, G., Chen, C., Gong, Q., Xie, G., Yao, M., Tai, H., Jiang, Y., & Chen, J. (2021) · Advanced Materials · doi:10.1002/adma.202101262 · Cited by 481
Review—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
Evolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Metadata
- Authors
- Righettoni, M., Amann, A., & Pratsinis, S. E.
- Venue
- Materials Today
- Publisher
- Elsevier BV
- Published
- 2015-04
- Volume
- 18
- Issue
- 3
- Pages
- 163-171
- ISSN
- 1369-7021 (ISSN-L)
- OpenAlex
- W2030710415
- Cited by
- 487
- References
- 5
- FWCI
- 12.91
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Breath analysis by nanostructured metal oxides as chemo-resistive gas sensors. https://app.cochat.ai/papers/10.1016/j.mattod.2014.08.017
- The paper
- Righettoni, M., Amann, A., & Pratsinis, S. E. (2015). Breath analysis by nanostructured metal oxides as chemo-resistive gas sensors. Materials Today. https://doi.org/10.1016/j.mattod.2014.08.017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.