The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Electrically conductive and fluorine free superhydrophobic strain sensors based on SiO2/graphene-decorated electrospun nanofibers for human motion monitoring
Abstract
It is desirable and still challenging to develop flexible, breathable and anti-corrosive wearable strain sensors with high stretchability and sensitivity that can realize full range body motions. Here, a superhydrophobic and conductive nanofiber composites (SCNCs) with a hierarchical SiO2/graphene shell and polyurethane (PU) nanofiber core microstructure were fabricated by assembling graphene on PU nanofibers under the assistance of ultrasonication, followed by stretching-induced SiO2 nanoparticles decoration onto the graphene shell. The introduction of graphene and SiO2 nanoparticles improves both Young’s modulus, tensile strength and the elongation at break of PU nanofibrous membrane. The superhydrophobicity and conductivity can be almost maintained after the SCNCs are subject to cyclic stretching or abrasion or even exposed to harsh conditions. When used as strain sensors, the SCNCs show high stretchability, reliability and good durability and can be used in harsh environment including acid and salt conditions. The SCNCs are then assembled to monitor full range body motions including both subtle and large body movements, making it a promising candidate in wearable electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review
Amjadi, M., Kyung, K., Park, I., & Sitti, M. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504755 · Cited by 3,202
Highly Stretchable Piezoresistive Graphene–Nanocellulose Nanopaper for Strain Sensors
Yan, C., Wang, J., Kang, W., Cui, M., Wang, X., Foo, C. Y., Chee, K. J., & Lee, P. S. (2014) · Advanced Materials · doi:10.1002/adma.201304742 · Cited by 1,179
Sensitive, High-Strain, High-Rate Bodily Motion Sensors Based on Graphene–Rubber Composites
Boland, C. S., Khan, U., Backes, C., O’Neill, A., McCauley, J., Duane, S., Shanker, R., Liu, Y., Jurewicz, I., Dalton, A. B., et al. (2014) · ACS Nano · doi:10.1021/nn503454h · Cited by 793
Liu, Q., Chen, J., Li, Y., & Shi, G. (2016) · ACS Nano · doi:10.1021/acsnano.6b03813 · Cited by 609
Yu, G.-F., Yan, X., Yu, M., Jia, M.-Y., Pan, W., He, X.-X., Han, W.-P., Zhang, Z.-M., Yu, L.-M., & Long, Y.-Z. (2016) · Nanoscale · doi:10.1039/c5nr08618c · Cited by 154
Cited by
Developments of Advanced Electrospinning Techniques: A Critical Review
Li, Y., Zhu, J., Cheng, H., Li, G., Cho, H., Jiang, M., Gao, Q., & Zhang, X. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202100410 · Cited by 578
Advances in graphene-based flexible and wearable strain sensors
Chen, H., Zhuo, F., Zhou, J., Liu, Y., Zhang, J., Dong, S., Liu, X., Elmarakbi, A., Duan, H., & Fu, Y. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2023.142576 · Cited by 386
Electrospun nanofiber-based soft electronics
Wang, Y., Yokota, T., & Someya, T. (2021) · NPG Asia Materials · doi:10.1038/s41427-020-00267-8 · Cited by 267
Progress of flexible strain sensors for physiological signal monitoring
Shen, Z., Liu, F., Huang, S., Wang, H., Yang, C., Hang, T., Tao, J., Xia, W., & Xie, X. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114298 · Cited by 250
Self-citation
Metadata
- Authors
- Gao, J., Li, B., Huang, X., Wang, L., Lin, L., Wang, H., & Xue, H.
- Venue
- Chemical Engineering Journal
- Publisher
- Elsevier BV
- Published
- 2019-10
- Volume
- 373
- Pages
- 298-306
- ISSN
- 1385-8947 (ISSN-L)
- OpenAlex
- W2944742639
- Cited by
- 231
- References
- 5
- FWCI
- 10.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.