Comparative performance assessment of plasma reactors for the treatment of PFOA; reactor design, kinetics, mineralization and energy yield
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The development of efficient plasma-based technologies for water treatment in general and decontamination from perfluoroalkyl substances, in particular, is a timely and challenging research topic. This study investigated the degradation of PFOA (perfluorooctanoic acid) in water using three reactors with different configurations and implementing different plasma regimes. Two reactors were available from previous studies on other recalcitrant pollutants and use, respectively, corona discharge and plasma in gas bubbles. The third reactor was designed and developed for this specific application and uses a self-pulsing streamer discharge (SPD) over the liquid surface. The performance of the three reactors was assessed and compared using air as plasma feed gas and a PFOA solution (41.4 mg/L) in Milli-Q-water. The SPD reactor was found to be the most efficient in terms of energy efficiency and PFOA conversion and degradation rate. It was therefore further tested and characterized by studying the effects of changing the aqueous media in which PFOA was dissolved (Milli-Q and tap water) and the plasma feed gas (synthetic air, ambient air and argon). Due to the formation of nitrous and nitric acids, especially for plasma generated in ambient and synthetic air, the solution pH, conductivity, and hence the plasma input power changed significantly during the experiments. The best results were obtained using argon for plasma inception and PFOA solutions in tap water: the energy efficiency and fluoride recovery were 561 mg/kWh and 47%, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trojanowicz, M., Bojanowska-Czajka, A., Bartosiewicz, I., & Kulisa, K. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2017.10.153 · Cited by 550
Physico-Chemical Processes for the Treatment of Per- And Polyfluoroalkyl Substances (PFAS): A review
Nzeribe, B. N., Crimi, M., Mededovic Thagard, S., & Holsen, T. M. (2019) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2018.1542916 · Cited by 314
Ion exchange resin for PFAS removal and pilot test comparison to GAC
Woodard, S., Berry, J., & Newman, B. (2017) · Remediation Journal · doi:10.1002/rem.21515 · Cited by 250
Dauchy, X., Boiteux, V., Colin, A., Hémard, J., Bach, C., Rosin, C., & Munoz, J.-F. (2019) · Chemosphere · doi:10.1016/j.chemosphere.2018.10.003 · Cited by 192
Occurrence and sources of perfluoroalkyl acids in Italian river basins
Valsecchi, S., Rusconi, M., Mazzoni, M., Viviano, G., Pagnotta, R., Zaghi, C., Serrini, G., & Polesello, S. (2015) · Chemosphere · doi:10.1016/j.chemosphere.2014.07.044 · Cited by 139
Cited by
Emerging technologies for PFOS/PFOA degradation and removal: A review
Leung, S. C. E., Shukla, P., Chen, D., Eftekhari, E., An, H., Zare, F., Ghasemi, N., Zhang, D., Nguyen, N.-T., & Li, Q. (2022) · Science of The Total Environment · doi:10.1016/j.scitotenv.2022.153669 · Cited by 334
Comparison of currently available PFAS remediation technologies in water: a review
Wanninayake, D. M. (2021) · Journal of Environmental Management · doi:10.1016/j.jenvman.2021.111977 · Cited by 332
Liu, Z., Bentel, M. J., Yu, Y., Ren, C., Gao, J., Pulikkal, V. F., Sun, M., Men, Y., & Liu, J. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.1c00353 · Cited by 198
Zhang, H., Li, P., Zhang, A., Sun, Z., Liu, J., Héroux, P., & Liu, Y. (2021) · Environmental Science & Technology · doi:10.1021/acs.est.1c01724 · Cited by 184
PFAS Degradation in Ultrapure and Groundwater Using Non-Thermal Plasma
Palma, D., Papagiannaki, D., Lai, M., Binetti, R., Sleiman, M., Minella, M., & Richard, C. (2021) · Molecules · doi:10.3390/molecules26040924 · Cited by 70
Metadata
- Authors
- Saleem, M., Biondo, O., Sretenović, G., Tomei, G., Magarotto, M., Pavarin, D., Marotta, E., & Paradisi, C.
- Venue
- Chemical Engineering Journal
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 382
- Pages
- 123031
- ISSN
- 1385-8947 (ISSN-L)
- OpenAlex
- W2979364787
- Cited by
- 118
- References
- 5
- FWCI
- 4.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative performance assessment of plasma reactors for the treatment of PFOA; reactor design, kinetics, mineralization and energy yield. https://app.cochat.ai/papers/10.1016/j.cej.2019.123031
- The paper
- Saleem, M., Biondo, O., Sretenović, G., Tomei, G., Magarotto, M., Pavarin, D., Marotta, E., & Paradisi, C. (2020). Comparative performance assessment of plasma reactors for the treatment of PFOA; reactor design, kinetics, mineralization and energy yield. Chemical Engineering Journal. https://doi.org/10.1016/j.cej.2019.123031
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.