Treatment of perfluoroalkyl acids in concentrated wastes from regeneration of spent ion exchange resin by electrochemical oxidation using Magnéli phase Ti4O7 anode
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
This study investigated the treatment of perfluoroalkyl acids (PFAAs) in still bottoms during electrochemical oxidation using Magnéli phase titanium suboxide (Ti4O7) as the anode. Still bottoms are wastes produced from regeneration of saturated ion exchange resin (IXR) by a solution containing high salt content and methanol followed by distillation to remove the methanol. All 10 monitored PFAAs were effectively degraded by electrochemical oxidation (EO) on a Magnéli phase Ti4O7 anode, and the removal was 61.1% after 40 h EO treatment of a still bottoms sample that was produced from the use of a typical regenerant containing 2% NaCl and 80% methanol by mass. Total Organic Carbon (TOC) destruction exceeded 79% in this treatment. Chlorate (ClO3−) and perchlorate (ClO4−) were formed after 8 h and reached a maximum of 2.3 mM and 2.2 mM, respectively, after 40 h. To minimize perchlorate generation by EO, five other salts were also tested instead of NaCl to regenerate IXR that had treated groundwater containing PFAAs. The regenerant containing NaI exhibited the greatest PFAAs elution, comparable to that of NaCl. EO treatment of the still bottoms produced from the NaI regenerant for 200 h led to a total of 98.1% removal of all 10 monitored PFAAs. No ClO3− or ClO4− was detected after 100 h of EO treatment. It was found that the methanol residue in still bottoms effectively suppressed the formation of ClO3− and ClO4− during electrooxidation by scavenging chlorine radicals. The results of this study demonstrate the promise of coupling regenerable IXR technology and EO for removing PFAAs from water and destroying them onsite.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polyfluorinated Compounds: Past, Present, and Future
Lindstrom, A. B., Strynar, M. J., & Libelo, E. L. (2011) · Environmental Science & Technology · doi:10.1021/es2011622 · Cited by 1,628
Conder, J. M., Hoke, R. A., Wolf, W. D., Russell, M. H., & Buck, R. C. (2008) · Environmental Science & Technology · doi:10.1021/es070895g · Cited by 1,206
Rahman, M. F., Peldszus, S., & Anderson, W. B. (2014) · Water Research · doi:10.1016/j.watres.2013.10.045 · Cited by 1,022
Perfluoroalkyl and polyfluoroalkyl substances in consumer products
Kotthoff, M., Müller, J., Jürling, H., Schlummer, M., & Fiedler, D. (2015) · Environmental Science and Pollution Research · doi:10.1007/s11356-015-4202-7 · Cited by 613
A review of emerging technologies for remediation of PFASs
Ross, I., McDonough, J., Miles, J., Storch, P., Thelakkat Kochunarayanan, P., Kalve, E., Hurst, J., S. Dasgupta, S., & Burdick, J. (2018) · Remediation Journal · doi:10.1002/rem.21553 · Cited by 606
Degradation and Removal Methods for Perfluoroalkyl and Polyfluoroalkyl Substances in Water
Merino, N., Qu, Y., Deeb, R. A., Hawley, E. L., Hoffmann, M. R., & Mahendra, S. (2016) · Environmental Engineering Science · doi:10.1089/ees.2016.0233 · Cited by 349
Ion exchange resin for PFAS removal and pilot test comparison to GAC
Woodard, S., Berry, J., & Newman, B. (2017) · Remediation Journal · doi:10.1002/rem.21515 · Cited by 250
Self-citationElectrochemical oxidation of perfluorinated compounds in water
Niu, J., Li, Y., Shang, E., Xu, Z., & Liu, J. (2016) · Chemosphere · doi:10.1016/j.chemosphere.2015.11.115 · Cited by 243
Australia-wide assessment of perfluoroalkyl substances (PFASs) in landfill leachates
Gallen, C., Drage, D., Eaglesham, G., Grant, S., Bowman, M., & Mueller, J. F. (2017) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2017.02.006 · Cited by 224
Soriano, A., Schaefer, C., & Urtiaga, A. (2020) · Chemical Engineering Journal Advances · doi:10.1016/j.ceja.2020.100042 · Cited by 82
Cited by
Remediation of water from per-/poly-fluoroalkyl substances (PFAS)–Challenges and perspectives
Garg, S., Wang, J., Kumar, P., Mishra, V., Arafat, H., Sharma, R. S., & Dumée, L. F. (2021) · Journal of Environmental Chemical Engineering · doi:10.1016/j.jece.2021.105784 · Cited by 139
Occurrence of per- and polyfluoroalkyl substances in water: a review
Wang, Y., Kim, J., Huang, C.-H., Hawkins, G. L., Li, K., Chen, Y., & Huang, Q. (2022) · Environmental Science: Water Research & Technology · doi:10.1039/d1ew00851j · Cited by 31
Self-citation
Metadata
- Authors
- Wang, L., Nickelsen, M., Chiang, S.-Y. (., Woodard, S., Wang, Y., Liang, S., Mora, R., Fontanez, R., Anderson, H., & Huang, Q.
- Venue
- Chemical Engineering Journal Advances
- Publisher
- Elsevier BV
- Published
- 2021-03
- Volume
- 5
- Pages
- 100078
- ISSN
- 2666-8211 (ISSN-L)
- OpenAlex
- W3116042373
- Cited by
- 51
- References
- 10
- FWCI
- 2.52
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Treatment of perfluoroalkyl acids in concentrated wastes from regeneration of spent ion exchange resin by electrochemical oxidation using Magnéli phase Ti4O7 anode. https://app.cochat.ai/papers/10.1016/j.ceja.2020.100078
- The paper
- Wang, L., Nickelsen, M., Chiang, S.-Y. (., Woodard, S., Wang, Y., Liang, S., Mora, R., Fontanez, R., Anderson, H., & Huang, Q. (2021). Treatment of perfluoroalkyl acids in concentrated wastes from regeneration of spent ion exchange resin by electrochemical oxidation using Magnéli phase Ti4O7 anode. Chemical Engineering Journal Advances. https://doi.org/10.1016/j.ceja.2020.100078
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.