Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 263

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Left Bundle Branch Pacing for Cardiac Resynchronization Therapy: Nonrandomized On-Treatment Comparison With His Bundle Pacing and Biventricular Pacing

Open access
Wu, Shengjie, Su, Lan, Vijayaraman, Pugazhendhi, Zheng, Rujie, Cai, Mengxing, Xu, Lei, Shi, Ruiyu, Huang, Zhouqing, Whinnett, Zachary I., Huang, Weijian · 2021 · Canadian Journal of Cardiology

Abstract

BACKGROUND Left bundle branch pacing (LBBP) is a novel method for delivering cardiac resynchronization therapy (CRT). We compared on treatment outcomes to His bundle pacing (HBP) and biventricular pacing (BVP) in this non-randomized observational study. METHODS Consecutive patients with LVEF ≤40% and typical LBBB referred for CRT received either BVP, HBP or LBBP. QRS duration(d), pacing threshold, LVEF, New York Heart Association (NYHA) Class were assessed. RESULTS 137 patients were recruited, 49 HBP, 32 LBBP and 54 BVP, while 2 did not receive CRT. The majority of patients had non-ischemic cardiomyopathy. Mean paced QRSd was 100.7±15.3ms, 110.8±11.1ms and 135.4±20.2ms during HBP, LBBP and BVP, respectively. HBP and LBBP demonstrated a similar absolute increase(Δ) in LVEF (+23.9% vs +24%, P=0.977) and rate of normalized final LVEF (74.4% vs 70.0%, P=0.881) at 1-year follow-up. This was significantly higher than in the BVP group (ΔLVEF +16.7% and 44.9% rate of normalized final LVEF, P<0.005). HBP and LBBP also demonstrated greater improvements in NYHA class compared to BVP. LBBP was associated with higher R-wave amplitude (11.2±5.1mV vs. 3.8±1.9mV, P<0.001) and lower pacing threshold (0.49±0.13V/0.5ms vs. 1.35±0.73 V/0.5ms, P<0.001) compared to HBP. CONCLUSION Left bundle branch pacing appears to be a promising method for delivering CRT. We observed similar improvements in symptoms and LV function with LBBP and HBP. These improvements were significantly greater than those seen in patients treated with BVP, in this non-randomized study. These promising findings justify further investigation with randomized trials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cjca.2020.04.037

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 263

Metadata

Authors
Wu, S., Su, L., Vijayaraman, P., Zheng, R., Cai, M., Xu, L., Shi, R., Huang, Z., Whinnett, Z. I., & Huang, W.
Venue
Canadian Journal of Cardiology
Publisher
Elsevier BV
Published
2021-02
Volume
37
Issue
2
Pages
319-328
ISSN
0828-282X (ISSN-L)
OpenAlex
W3020938461
Cited by
263
References
22
FWCI
27.37
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.