Current-controlled deep brain stimulation reduces in vivo voltage fluctuations observed during voltage-controlled stimulation
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objective Clinical deep brain stimulation (DBS) systems typically utilize voltage-controlled stimulation and thus the voltage distribution generated in the brain can be affected by electrode impedance fluctuations. The goal of this study was to experimentally evaluate the theoretical advantages of using current-controlled pulse generators for DBS applications. Methods Time-dependent changes in the voltage distribution generated in the brain during voltage-controlled and current-controlled DBS were monitored with in vivo experimental recordings performed in non-human primates implanted with scaled-down clinical DBS electrodes. Results In the days following DBS lead implantation, electrode impedance progressively increased. Application of continuous stimulation through the DBS electrode produced a decrease in the electrode impedance in a time dependent manner, with the largest changes occurring within the first hour of stimulation. Over that time period, voltage-controlled stimuli exhibited an increase in the voltage magnitudes generated in the tissue near the DBS electrode, while current-controlled DBS showed minimal changes. Conclusion Large electrode impedance changes occur during DBS. During voltage-controlled stimulation, these impedance changes were significantly correlated with changes in the voltage distribution generated in the brain. However, these effects can be minimized with current-controlled stimulation. Significance The use of current-controlled DBS may help minimize time-dependent changes in therapeutic efficacy that can complicate patient programming when using voltage-controlled DBS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1×
“After an electrode is implanted into the nervous system, there is a foreign-body reaction to the implanted device that results in the attachment of proteins and cells directly to the electrode contact and accumulation of extracellular matrix proteins and glia surrounding the device (Szarowski et al., 2003; Polikov et…”
BackgroundResponse of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“After an electrode is implanted into the nervous system, there is a foreign-body reaction to the implanted device that results in the attachment of proteins and cells directly to the electrode contact and accumulation of extracellular matrix proteins and glia surrounding the device (Szarowski et al., 2003; Polikov et…”
BackgroundPerlmutter, J. S., & Mink, J. W. (2006) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.29.051605.112824 · Cited by 1,073 · cited 1×
“Deep brain stimulation (DBS) is an established therapy for the treatment of movement disorders and shows promise for the treatment of several neuropsychiatric disorders (Perlmutter and Mink, 2006).”
Cited by
Technology of deep brain stimulation: current status and future directions
Krauss, J. K., Lipsman, N., Aziz, T., Boutet, A., Brown, P., Chang, J. W., Davidson, B., Grill, W. M., Hariz, M. I., Horn, A., et al. (2021) · Nature Reviews Neurology · doi:10.1038/s41582-020-00426-z · Cited by 919
Okun, M. S., Gallo, B. V., Mandybur, G., Jagid, J., Foote, K. D., Revilla, F. J., Alterman, R., Jankovic, J., Simpson, R., Junn, F., et al. (2012) · The Lancet Neurology · doi:10.1016/s1474-4422(11)70308-8 · Cited by 409
Self-citationLozano, A. M., Giacobbe, P., Hamani, C., Rizvi, S. J., Kennedy, S. H., Kolivakis, T. T., Debonnel, G., Sadikot, A. F., Lam, R. W., Howard, A. K., et al. (2012) · Journal of Neurosurgery · doi:10.3171/2011.10.jns102122 · Cited by 356
Koeglsperger, T., Palleis, C., Hell, F., Mehrkens, J. H., & Bötzel, K. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2019.00410 · Cited by 235
A Fully Integrated RF-Powered Energy-Replenishing Current-Controlled Stimulator
Ha, S., Kim, C., Park, J., Cauwenberghs, G., & Mercier, P. P. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2881800 · Cited by 35
Shadmani, A., Viswam, V., Chen, Y., Bounik, R., Dragas, J., Radivojevic, M., Geissler, S., Sitnikov, S., Muller, J., & Hierlemann, A. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2890530 · Cited by 24
“the volume of the tissue that is stimulated [13], [14].”
Metadata
- Authors
- Lempka, S. F., Johnson, M. D., Miocinovic, S., Vitek, J. L., & McIntyre, C. C.
- Venue
- Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 2010-12
- Volume
- 121
- Issue
- 12
- Pages
- 2128-2133
- ISSN
- 1388-2457 (ISSN-L)
- OpenAlex
- W1968788056
- Cited by
- 135
- References
- 3
- FWCI
- 3.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.