Electrode montages for tDCS and weak transcranial electrical stimulation: Role of “return” electrode’s position and size
Open accessAbstract
In this issue, Moliadze and colleagues investigate the role of electrode montage in the induction of acute lasting excitability changes by transcranial Direction Current Stimulation (tDCS) and transcranial Random Noise Stimulation (tRNS); specifically they demonstrate that during weak transcranial electrical stimulation, the position of the “return” electrode affects neuromodulation under the “active” electrode. Moliadze and colleagues introduce the development of modern tDCS protocols at the turn of the decade (Priori et al., 1998; Nitsche and Paulus, 2000, 2001; Terney et al., 2008). Despite wide-spread subsequent dissemination of tDCS, there remain significant unknowns about the mechanisms of tDCS and the design of electrode montages, including electrode size and placement. Moliadze and colleagues address the role of “return” electrode’s position (and distance) in the induction of Transcranial Magnetic Stimulation (TMS) evoked excitability changes under an “active” electrode over motor cortex (Moliadze et al., 2010). Understanding and controlling electrotherapy dose is evidently critical in determining behavioral and clinical outcome. The position of stimulating electrodes governs current flow through the body, and hence the distribution of induced electric fields in the brain. These induced cortical currents/electric fields modulate neuronal excitability for DC stimulation and, in turn, determine behavioral and clinical outcomes (Bikson et al., 2008). The most simplistic dose design schemes for tDCS assume a region of “increased excitability” in the cortex directly under the anode electrode, and a region of “decreased excitability’ under the cathode, with intermediary regions largely spared (unaffected). Several studies have suggested limitations in this simplified approach including the need to consider: 1) Current density at the electrode (Nitsche et al., 2007; Miranda et al., 2006; Miranda et al., 2009); 2) Individual differences (Madhavan et al., 2010); 3) Significant current flow in intermediary regions, including the potential for current clustering (Datta et al, 2009); 4) Montages for unidirectional modulation (Rossini et al., 1985; Saypol et al.,1991; Datta et al., 2008); and 5) Relative electrode position, including inter-electrode distance (Stecker et al.,2005; Datta et al., 2008) and the use of extra-cephalic electrodes (Accornero et al., 2007; Ferrucci et al., 2008, Baker et al., 2010). Generally, increasing electrode separation on the head is expected to increase cortical modulation by increased relative amount of current entering the brain rather than “shunted” across the scalp. The report by Moliadze and colleagues provides some of the strongest clinical evidence to-date that the relative position of stimulation electrode can affect neuromodulation under each electrode – namely that in determining electrotherapy dose the two stimulating electrodes cannot be considered separately and independently, even for relatively distant electrode positions. Moreover, increasing electrode distance may decrease the magnitude of neuro-modulation, depending on the specific montage and physiological measure. The current flow through the body is strongly influenced by anatomical details, because of the different electrical conductivities of tissues such as scalp, skull/vertebrae, muscle, CSF, and brain – as a result the induced current profile in the brain may be detailed and complex. Given this, it is thus not surprising that the position of both electrodes determines the resulting current flow distribution through the cortex. Simultaneously, the complexity of current flow indicates that determining electrode montages dose by simplified assumptions may not be prudent, as highlighted by the results of Moliadze et al., 2010. One solution to addressing this complexity in the design of rational stimulation protocols is the prediction of current flow patterns through the brain using computer models. The sophistication of computer models using finite-element-methods (FEM) for this purpose (Butson et al., 2007; De Lucia et al., 2007) has increased to allow high-resolution (e.g. 1 mm; Datta et al., 2009) and individualized modeling (Wagner et al.,2007; Datta et al., in press). Figure 1 illustrates the resulting brain current flow for three electrode montages – in all cases, the size and position of the “active” electrode over motor cortex is fixed, while the position or size of the “return” electrode is varied. The position and size of the “return” electrode affects the electric field distribution across the entire cortex. In addition, changing the position of the “return” electrode affects the electric field distribution in cortex directly under the “active” electrode. Figure 1 Effect of “return” electrode’s position and size on cortical electric fields induced by a 4 cm × 4 cm “active” electrode over the left primary motor cortex. An individualized FEM head model was created from ... Our modeling results support the clinical finding by Moliadze and colleagues that even if the direct actions of the “return” electrode are mitigated by its position (e.g. extracephalic) or size (Nitsche et al., 2007); the “return” electrode will still influence the current path through the brain from the “active” electrode. For example, the repositioning of the return pad from the contralateral forehead to the contralateral upper arm may have shifted the preferential flow of current from across the frontal regions to across the posterior regions of the brain (see Montage A and C versus Montage B in Figure 1). More generally, the regions of brain modulation may not be simply under the “active” electrode (Datta et al., 2009; Sadleir et al., 2010), such that some “surprising” clinical findings, including by Moliadze and colleagues may be understood by considering the concurrent neuro-modulation of multiple cortical and sub-cortical regions. Additional experimental studies investigating the specific role of electrode placements and intensity, and careful consideration of electrode montage in designing therapeutic protocols, is warranted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitsche, M. A., & Paulus, W. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00633.x · Cited by 5,656
Sustained excitability elevations induced by transcranial DC motor cortex stimulation in humans
Nitsche, M. A., & Paulus, W. (2001) · Neurology · doi:10.1212/wnl.57.10.1899 · Cited by 2,617
Cited by
Brunoni, A. R., Nitsche, M. A., Bolognini, N., Bikson, M., Wagner, T., Merabet, L., Edwards, D. J., Valero-Cabre, A., Rotenberg, A., Pascual-Leone, A., et al. (2012) · Brain stimulation · doi:10.1016/j.brs.2011.03.002 · Cited by 1,445
Self-citationAntal, A., Alekseichuk, I., Bikson, M., Brockmöller, J., Brunoni, A. R., Chen, R., Cohen, L. G., Dowthwaite, G., Ellrich, J., Flöel, A., et al. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.001 · Cited by 1,301
Self-citationDirect effects of transcranial electric stimulation on brain circuits in rats and humans
Vöröslakos, M., Takeuchi, Y., Brinyiczki, K., Zombori, T., Oliva, A., Fernández-Ruiz, A., Kozák, G., Kincses, Z. T., Iványi, B., Buzsáki, G., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-02928-3 · Cited by 735
Transcranial direct current stimulation – update 2011
Nitsche, M. A., & Paulus, W. (2011) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-2011-0618 · Cited by 544
Transcranial Direct Current Stimulation (tDCS): A Beginner's Guide for Design and Implementation
Thair, H., Holloway, A. L., Newport, R., & Smith, A. D. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00641 · Cited by 513
Metadata
- Authors
- Bikson, M., Datta, A., Rahman, A., & Scaturro, J.
- Venue
- Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 2010-12
- Volume
- 121
- Issue
- 12
- Pages
- 1976-1978
- ISSN
- 1388-2457 (ISSN-L)
- OpenAlex
- W1994460453
- Cited by
- 284
- References
- 2
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrode montages for tDCS and weak transcranial electrical stimulation: Role of “return” electrode’s position and size. https://app.cochat.ai/papers/10.1016/j.clinph.2010.05.020
- The paper
- Bikson, M., Datta, A., Rahman, A., & Scaturro, J. (2010). Electrode montages for tDCS and weak transcranial electrical stimulation: Role of “return” electrode’s position and size. Clinical Neurophysiology. https://doi.org/10.1016/j.clinph.2010.05.020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.