The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Effect of EEG electrode number on epileptic source localization in pediatric patients
Open accessAbstract
Objective To investigate the relationship between EEG source localization and the number of scalp EEG recording channels.Methods 128 EEG channel recordings of 5 pediatric patients with medically intractable partial epilepsy were used to perform source localization of interictal spikes. The results were compared with surgical resection and intracranial recordings. Various electrode configurations were tested and a series of computer simulations based on a realistic head boundary element model were also performed in order to further validate the clinical findings.Results The improvement seen in source localization substantially decreases as the number of electrodes increases. This finding was evaluated using the surgical resection, intracranial recordings and computer simulation. It was also shown in the simulation that increasing the electrode numbers could remedy the localization error of deep sources. A plateauing effect was seen in deep and superficial sources with further increasing the electrode number.Conclusion The source localization is improved when electrode numbers increase, but the absolute improvement in accuracy decreases with increasing electrode number.Significance Increasing the electrode number helps decrease localization error and thus can more ably assist the physician to better plan for surgical procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Studies indicate that higher spatial sampling helps improve the precision of ESI (18, 19).”
From Electrophysiological source imaging: A noninvasive window to brain dynamics (2018) · cites this paper as [19]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standardized low-resolution brain electromagnetic tomography (sLORETA): technical details.
Pascual-Marqui, R. D. (2002) · PubMed · Cited by 3,329
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Picton, T. W., Bentin, S., Berg, P., Donchin, E., Hillyard, S. A., Johnson, R., Miller, G. A., Ritter, W., Ruchkin, D. S., Rugg, M. D., et al. (2000) · Psychophysiology · doi:10.1111/1469-8986.3720127 · Cited by 2,157
Dale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003
Baillet, S., Mosher, J., & Leahy, R. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,846
Michel, C., Murray, M. M., Lantz, G., Gonzalez, S., Spinelli, L., & de Peralta, R. G. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.06.001 · Cited by 1,771
Electric Fields of the Brain: The Neurophysics of EEG
Fermaglich, J. (1982) · JAMA · doi:10.1001/jama.1982.03320380071046 · Cited by 1,557
Surgical treatment of the epilepsies
Bloomfield, S. M., & Shetter, A. G. (1988) · Surgical Neurology · doi:10.1016/0090-3019(88)90022-5 · Cited by 1,206
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989
Spatial sampling of head electrical fields: the geodesic sensor net
Tucker, D. M. (1993) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(93)90121-b · Cited by 756
Cited by
Sorted by citations
The standardized EEG electrode array of the IFCN
Seeck, M., Koessler, L., Bast, T., Leijten, F., Michel, C., Baumgartner, C., He, B., & Beniczky, S. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.06.254 · Cited by 489
“A recent interictal study using 128-electrodes recordings in pediatric and adult epilepsy patients indicated that at least 64–76 electrodes are desirable to avoid significant source localization errors (Sohrabpour et al., 2015).”
Self-citationEEG source localization: Sensor density and head surface coverage
Song, J., Davey, C., Poulsen, C., Luu, P., Turovets, S. I., Anderson, E. W., Li, K., & Tucker, D. M. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.08.015 · Cited by 347
Electrophysiological source imaging: A noninvasive window to brain dynamics
He, B., Sohrabpour, A., Brown, E., & Liu, Z. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-120853 · Cited by 297
“Studies indicate that higher spatial sampling helps improve the precision of ESI (18, 19).”
BackgroundSelf-citationTMS combined with EEG: Recommendations and open issues for data collection and analysis
Hernandez-Pavon, J. C., Veniero, D., Bergmann, T. O., Belardinelli, P., Bortoletto, M., Casarotto, S., Casula, E. P., Farzan, F., Fecchio, M., Julkunen, P., et al. (2023) · Brain Stimulation · doi:10.1016/j.brs.2023.02.009 · Cited by 238
“16 that with optimal placement on the scalp, 30–50 electrodes would be enough to gather the spatial 429 information that is available to EEG [92-94].”
Electrophysiological Brain Connectivity: Theory and Implementation
He, B., Astolfi, L., Valdes-Sosa, P. A., Marinazzo, D., Palva, S., Bénar, C., Michel, C. M., & Koenig, T. W. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2913928 · Cited by 242
Self-citation
Metadata
- Authors
- Sohrabpour, A., Lu, Y., Kankirawatana, P., Blount, J., Kim, H., & He, B.
- Affiliations
- University of Minnesota (US)
- University of Alabama at Birmingham (US)
- Corresponding author
- He, Bin
- Venue
- Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 2015-03
- Volume
- 126
- Issue
- 3
- Pages
- 472-480
- ISSN
- 1388-2457 (ISSN-L)
- PMC
- PMC4289666
- OpenAlex
- W2020479538
- Cited by
- 149
- References
- 65
- Citations by year
- 2026: 2 · 2025: 14 · 2024: 9 · 2023: 29 · 2022: 13 · 2021: 16 · 2020: 10 · 2019: 19 · 2018: 8 · 2017: 9 · 2016: 10 · 2015: 7
- FWCI
- 5.21
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Clinical Neurophysiology (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- NIH (EB006433, EY023101, HL117664)
- NSF
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Clinical Neurology › Epilepsy research and treatment
- Physical Sciences › Computer Science › Signal Processing › Direction-of-Arrival Estimation Techniques
- Keywords
- EEG source localization, electrode number, pediatric epilepsy, interictal spikes, electrode configuration, surgical planning, intracranial recordings
- MeSH terms
- Adolescent, Brain, Brain Mapping, Child, Child, Preschool, Computer Simulation, Electrodes, Electroencephalography, Epilepsies, Partial, Female, Humans, Male
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review