High-density surface electromyography provides reliable estimates of motor unit behavior
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
OBJECTIVE To assess the intra- and inter-session reliability of estimates of motor unit behavior and muscle fiber properties derived from high-density surface electromyography (HDEMG). METHODS Ten healthy subjects performed submaximal isometric knee extensions during three recording sessions (separate days) at 10%, 30%, 50% and 70% of their maximum voluntary effort. The discharge timings of motor units of the vastus lateralis and medialis muscles were automatically identified from HDEMG by a decomposition algorithm. We characterized the number of detected motor units, their discharge rates, the coefficient of variation of their inter-spike intervals (CoVisi), the action potential conduction velocity and peak-to-peak amplitude. Reliability was assessed for each motor unit characteristics by intra-class correlation coefficient (ICC). Additionally, a pulse-to-noise ratio (PNR) was calculated, to verify the accuracy of the decomposition. RESULTS Good to excellent reliability within and between sessions was found for all motor unit characteristics at all force levels (ICCs>0.8), with the exception of CoVisi that presented poor reliability (ICC<0.6). PNR was high and similar for both muscles with values ranging between 45.1 and 47.6dB (accuracy>95%). CONCLUSION Motor unit features can be assessed non-invasively and reliably within and across sessions over a wide range of force levels. SIGNIFICANCE These results suggest that it is possible to characterize motor units in longitudinal intervention studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Understanding the minimum clinically important difference: A review of concepts and methods
Copay, A. G., Subach, B. R., Glassman, S. D., Polly, D. W., & Schuler, T. C. (2007) · The Spine Journal · doi:10.1016/j.spinee.2007.01.008 · Cited by 1,662
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
Self-citationHolobar, A., Minetto, M. A., & Farina, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016008 · Cited by 400
Self-citationTraining adaptations in the behavior of human motor units
Duchateau, J., Semmler, J. G., & Enoka, R. M. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00543.2006 · Cited by 354
Estimating motor unit discharge patterns from high-density surface electromyogram.
Holobar, A., Farina, D., Gazzoni, M., Merletti, R., & Zazula, D. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.10.160 · Cited by 318
Self-citationVila-Chã, C., Falla, D., & Farina, D. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01213.2009 · Cited by 178
Self-citationGallego, J. A., Dideriksen, J. L., Holobar, A., Ibanez, J., Glaser, V., Romero, J. P., Benito-Leon, J., Pons, J. L., Rocon, E., & Farina, D. (2015) · Journal of Neuroscience · doi:10.1523/jneurosci.0106-15.2015 · Cited by 67
Self-citationWatanabe, K., Gazzoni, M., Holobar, A., Miyamoto, T., Fukuda, K., Merletti, R., & Moritani, T. (2013) · Muscle & Nerve · doi:10.1002/mus.23828 · Cited by 58 · cited 2×
“With respect to studies involving patients, a similar criterion was used in people with diabetes (Watanabe et al., 2013) and”
BackgroundResult
Cited by
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
Wu, H., Yang, G., Zhu, K., Liu, S., Guo, W., Jiang, Z., & Li, Z. (2021) · Advanced Science · doi:10.1002/advs.202001938 · Cited by 395
A Modular, Smart, and Wearable System for High Density sEMG Detection
Cerone, G. L., Botter, A., & Gazzoni, M. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2904398 · Cited by 111
Metadata
- Authors
- Martinez-Valdes, E., Laine, C. M., Falla, D., Mayer, F., & Farina, D.
- Venue
- Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 2016-06
- Volume
- 127
- Issue
- 6
- Pages
- 2534-2541
- ISSN
- 1388-2457 (ISSN-L)
- OpenAlex
- W2204217836
- Cited by
- 133
- References
- 8
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-density surface electromyography provides reliable estimates of motor unit behavior. https://app.cochat.ai/papers/10.1016/j.clinph.2015.10.065
- The paper
- Martinez-Valdes, E., Laine, C. M., Falla, D., Mayer, F., & Farina, D. (2016). High-density surface electromyography provides reliable estimates of motor unit behavior. Clinical Neurophysiology. https://doi.org/10.1016/j.clinph.2015.10.065
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.