The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
On the efficiency of iterative ordered subset reconstruction algorithms for acceleration on GPUs
Open accessAbstract
Expectation Maximization (EM) and the Simultaneous Iterative Reconstruction Technique (SIRT) are two iterative computed tomography reconstruction algorithms often used when the data contain a high amount of statistical noise, have been acquired from a limited angular range, or have a limited number of views. A popular mechanism to increase the rate of convergence of these types of algorithms has been to perform the correctional updates within subsets of the projection data. This has given rise to the method of Ordered Subsets EM (OS-EM) and the Simultaneous Algebraic Reconstruction Technique (SART). Commodity graphics hardware (GPUs) has shown great promise to combat the high computational demands incurred by iterative reconstruction algorithms. However, we find that the special architecture and programming model of GPUs add extra constraints on the real-time performance of ordered subsets algorithms, counteracting the speedup benefits of smaller subsets observed on CPUs. This gives rise to new relationships governing the optimal number of subsets as well as relaxation factor settings for obtaining the smallest wall-clock time for reconstruction-a factor that is likely application-dependent. In this paper we study the generalization of SIRT into Ordered Subsets SIRT and show that this allows one to optimize the computational performance of GPU-accelerated iterative algebraic reconstruction methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Xu ve diğerleri [26] 2010 yılında 3B elektron tomografi iteratif geriçatma algoritmasını CUDA platformunu kullanarak hızlandırmışlardır.
“Xu ve diğerleri [26] 2010 yılında 3B elektron tomografi iteratif geriçatma algoritmasını CUDA platformunu kullanarak hızlandırmışlardır.”
From GPU Programlamada CUDA Platformu Kullanılan Paralel Görüntü İşleme Çalışmalarının İncelenmesi (2020) · cites this paper as [26]
Section 2.2 (page unavailable) explicitly says the reported results were obtained with GLSL shaders, not CUDA. The Conclusions (page unavailable) say the authors planned to investigate CUDA in future work. The paper studies GPU-accelerated iterative CT reconstruction, but the cited claim incorrectly describes it as a CUDA acceleration of 3D electron tomography. (LLM, conf=0.93)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredPalenstijn ve diğerleri [28] 2011 yılında Xu ve diğerlerinin [26] çalışmasını iyileştirmiş ve thread bloklarının ve belleğin daha verimli kullanılması sayesinde 10 kata varan hızlanma elde etmiştir.
“Çalışmada thread bloklarının ve belleğin daha verimli kullanılması sayesinde 10 kata varan hızlanma elde edilmiştir.”
From GPU Programlamada CUDA Platformu Kullanılan Paralel Görüntü İşleme Çalışmalarının İncelenmesi (2020) · cites this paper as [26]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,713
Gordon, R., Bender, R., & Herman, G. T. (1970) · Journal of Theoretical Biology · doi:10.1016/0022-5193(70)90109-8 · Cited by 2,817
A Survey of General‐Purpose Computation on Graphics Hardware
Owens, J. D., Luebke, D. P., Govindaraju, N. K., Harris, M., Krüger, J., Lefohn, A. E., & Purcell, T. J. (2007) · Computer Graphics Forum · doi:10.1111/j.1467-8659.2007.01012.x · Cited by 2,107
Andersen, A. H., & Kak, A. C. (1984) · Ultrasonic Imaging · doi:10.1177/016173468400600107 · Cited by 1,502
Iterative methods for the three-dimensional reconstruction of an object from projections
Gilbert, P. F. C. (1972) · Journal of Theoretical Biology · doi:10.1016/0022-5193(72)90180-4 · Cited by 1,427
Andersen, A. H. (1984) · Ultrasonic Imaging · doi:10.1016/0161-7346(84)90008-7 · Cited by 1,162
The CG Tutorial: The Definitive Guide to Programmable Real-Time Graphics
Fernando, R., & Kilgard, M. J. (2003) · CERN Document Server (European Organization for Nuclear Research) · Cited by 303
Algebraic reconstruction in CT from limited views
Andersen, A. H. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.20361 · Cited by 279
Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware
Xu, F., & Mueller, K. D. (2005) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2005.851398 · Cited by 252
Self-citationUnmatched projector/backprojector pairs in an iterative reconstruction algorithm
Zeng, G. L., & Gullberg, G. T. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.870265 · Cited by 228
Real-time 3D computed tomographic reconstruction using commodity graphics hardware
Xu, F., & Mueller, K. D. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/006 · Cited by 224
Self-citationA Survey of General-Purpose Computation on Graphics Hardware
Owens, J. D., Luebke, D. P., Govindaraju, N. K., et al. (2005) · eScholarship (California Digital Library) · doi:10.2312/egst.20051043 · Cited by 149
Mueller, K. D., & Yagel, R. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.897815 · Cited by 130
Self-citationMR image reconstruction using the GPU
Schiwietz, T., Chang, T., Speier, P., & Westermann, R. (2006) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.652223 · Cited by 61
On Block-Iterative Entropy Maximization
Censor, Y., & Segman, J. (1987) · Journal of Information and Optimization Sciences · doi:10.1080/02522667.1987.10698894 · Cited by 55
Kole, J. S., & Beekman, F. J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/4/008 · Cited by 41
Xue, X., Cheryauka, A., & Tubbs, D. (2006) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.653839 · Cited by 40
Flagged first, then by citations
Cited by
Sorted by citations
Xu, W., Xu, F., Jones, M., Keszthelyi, B., Sedat, J., Agard, D., & Mueller, K. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2010.03.018 · Cited by 71
Self-citationA distributed multi-GPU system for high speed electron microscopic tomographic reconstruction
Zheng, S. Q., Branlund, E., Kesthelyi, B., Braunfeld, M. B., Cheng, Y., Sedat, J. W., & Agard, D. A. (2011) · Ultramicroscopy · doi:10.1016/j.ultramic.2011.03.015 · Cited by 13
Self-citationGPU Programlamada CUDA Platformu Kullanılan Paralel Görüntü İşleme Çalışmalarının İncelenmesi
AYDIN, S., SAMET, R., & BAY, Ö. F. (2020) · Politeknik Dergisi · doi:10.2339/politeknik.563767 · Cited by 3
“compensation using graphics processing units (GPUs)”, Journal of Structural Biology, 171: 142–153, (2010) [27] Xu F.”
Method
Metadata
- Authors
- Xu, F., Xu, W., Jones, M., Keszthelyi, B., Sedat, J., Agard, D., & Mueller, K.
- Affiliations
- Stony Brook University (US)
- Howard Hughes Medical Institute (US)
- Venue
- Computer Methods and Programs in Biomedicine
- Publisher
- Elsevier BV
- Published
- 2010-06
- Volume
- 98
- Issue
- 3
- Pages
- 261-270
- ISSN
- 0169-2607 (ISSN-L)
- PMC
- PMC2871068
- OpenAlex
- W2103616940
- Cited by
- 63
- References
- 18
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 2 · 2023: 1 · 2022: 2 · 2020: 1 · 2019: 2 · 2018: 3 · 2017: 3 · 2016: 7 · 2015: 4 · 2014: 5 · 2013: 8 · 2012: 4
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Computer Methods and Programs in Biomedicine (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Science Foundation
- Howard Hughes Medical Institute
- National Institutes of Health (5r21eb004099-02)
- National Institute of General Medical Sciences (GM 31627, R01GM031627)
- National Institute of Biomedical Imaging and Bioengineering (R21 EB004099, R21 EB004099-01)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Physical Sciences › Computer Science › Hardware and Architecture › Parallel Computing and Optimization Techniques
- Physical Sciences › Computer Science › Computer Graphics and Computer-Aided Design › Computer Graphics and Visualization Techniques
- Keywords
- ordered subsets, iterative reconstruction, GPU acceleration, computed tomography, SIRT, SART, expectation-maximization algorithm, relaxation parameter, real-time performance, parallel computing
- MeSH terms
- Algorithms, Computer Graphics, Humans, Image Processing, Computer-Assisted, Software
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review