CoChat

YOLO Based Breast Masses Detection and Classification in Full-Field Digital Mammograms

Aly, Ghada Hamed, Marey, Mohammed, El-Sayed, Safaa Amin, Tolba, Mohamed Fahmy · 2021 · Computer Methods and Programs in Biomedicine
Cited by 201

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

BACKGROUND AND OBJECTIVE With the recent development in deep learning since 2012, the use of Convolutional Neural Networks (CNNs) in bioinformatics, especially medical imaging, achieved tremendous success. Besides that, breast masses detection and classifications in mammograms and their pathology classification are considered a critical challenge. Till now, the evaluation process of the screening mammograms is held by human readers which is considered very monotonous, tiring, lengthy, costly, and significantly prone to errors. METHODS We propose an end to end computer-aided diagnosis system based on You Only Look Once (YOLO). The proposed system first preprocesses the mammograms from their DICOM format to images without losing data. Then, it detects masses in full-field digital mammograms and distinguishes between the malignant and benign lesions without any human intervention. YOLO has three different architectures, and, in this paper, the three versions are used for mass detection and classification in the mammograms to compare their performance. The use of anchors in YOLO-V3 on the original form of data and its augmented version is proved to improve the detection accuracy especially when the k-means clustering is applied to generate anchors corresponding to the used dataset. Finally, ResNet and Inception are used as feature extractors to compare their classification performance against YOLO. RESULTS Mammograms with different resolutions are used and based on YOLO-V3, the best results are obtained through detecting 89.4% of the masses in the INbreast mammograms with an average precision of 94.2% and 84.6% for classifying the masses as benign and malignant respectively. YOLO's classification network is replaced with ResNet and InceptionV3 to get overall accuracy of 91.0% and 95.5%, respectively. CONCLUSION The proposed system showed using the experimental results the YOLO impact on the breast masses detection and classification. Especially using the anchor boxes concept in YOLO-V3 that are generated by applying k-means clustering on the dataset, we can detect most of the challenging cases of masses and classify them correctly. Also, by augmenting the dataset using different approaches and comparing with other recent YOLO based studies, it is found that augmenting the training set only is the fairest and accurate to be applied in the realistic scenarios.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cmpb.2020.105823

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 201

Metadata

Authors
Aly, G. H., Marey, M., El-Sayed, S. A., & Tolba, M. F.
Venue
Computer Methods and Programs in Biomedicine
Publisher
Elsevier BV
Published
2021-03
Volume
200
Pages
105823
ISSN
0169-2607 (ISSN-L)
OpenAlex
W3096265120
Cited by
201
References
11
FWCI
9.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.