Cited by 30Effects of Vibration on HealthTactile and Sensory InteractionsHuman auditory perception and evaluation

Vibrotactile and thermal perception and its relation to finger skin thickness

Open access
Lundström, Ronnie, Dahlqvist, Håkan, Hagberg, Mats, Nilsson, Tohr·2018·Clinical Neurophysiology Practice

Abstract

OBJECTIVE: Quantitative measurements of vibrotactile and thermotactile perception thresholds (VPT and TPT, respectively) rely on responses from sensory receptors in the skin when mechanical or thermal stimuli are applied to the skin. The objective was to examine if there is a relation between skin thickness (epidermis and dermis) and VPT or TPT. METHODS: Perception thresholds were measured on the volar side of the fingertip on 148 male subjects, out of which 116 were manual workers exposed to hand-transmitted vibration and 32 were white-collar (office) workers. Skin thickness was measured using a high-frequency ultrasonic derma scanner system. RESULTS: The difference in age, perception thresholds and skin thickness between manual and office workers was small and non-significant except for the perception of cold, which was decreased by vibration exposure. Skin thickness for both subgroups was mean 0.57 mm (range 0.25-0.93 mm). Increased age was associated with decreased perception of warmth and vibration. Lifetime cumulative exposure to vibration, but not age, was associated with decreased perception of cold. CONCLUSION: > .05) was found between finger skin thickness in the range of about 0.1-1 mm and vibration perception threshold for test frequencies from 8 to 500 Hz and thermotactile perception thresholds for warmth and cold. Increasing age was associated with reduced perception of vibration and warmth. Vibration exposure was associated with decreased perception of cold. SIGNIFICANCE: Skin thickness is a factor that may affect the response from sensory receptors, e.g., due to mechanical attenuation and thermal insulation. Thus, to evaluate perception threshold measurements, it is necessary to know if elevated thresholds can be attributed to skin thickness. No previous studies have measured skin thickness as related to vibrotactile and thermotactile perception thresholds. This study showed no association between skin thickness and vibrotactile perception or thermotactile perception.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cnp.2018.01.001

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • There exists tremendous variation even within a given body site caused by factors such as age, gender, BMI, sun-damage, and experimental methodology, leading to coefficients of variation up to 40%.

    “However, there exists tremendous variation even within a given body site caused by factors such as age, gender, BMI, sun-damage, and experimental methodology, leading to coefficients of variation up to 40% [139,140,141].”
  • The fingertips have the thinnest skin, followed by the forearm, dorsal hand, cheek, and forehead.

    “Overall, the literature has shown that the fingertips have the thinnest skin, followed by the forearm, dorsal hand, cheek, and forehead [139].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lundström, R., Dahlqvist, H., Hagberg, M., & Nilsson, T.
Affiliations
  • Umeå University (SE)
  • Karlstad University (SE)
  • Sahlgrenska University Hospital (SE)
Corresponding author
Lundström, Ronnie
Venue
Clinical Neurophysiology Practice
Publisher
Elsevier BV
Published
2018
Volume
3
Pages
33-39
ISSN
2467-981X (ISSN-L)
OpenAlex
W2785725478
Cited by
30
References
12
Citations by year
2026: 4 · 2025: 5 · 2024: 9 · 2023: 2 · 2022: 1 · 2021: 3 · 2020: 5 · 2018: 1
FWCI
2.45
Type
journal article
Language
en
Open access
Locations
  • Clinical Neurophysiology Practice (publishedVersion, cc-by-nc-nd)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • DiVA at Umeå University (Umeå University) (submittedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Swedish Council for Health, Working Life and Welfare
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Effects of Vibration on Health
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Physical Sciences › Engineering › Aerospace Engineering › Human auditory perception and evaluation
Keywords
vibration perception threshold, hand-arm vibration, occupational vibration exposure, cold sensation, perceived warmth, blue-collar workers, office workers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review