Vibrotactile and thermal perception and its relation to finger skin thickness
Open accessAbstract
OBJECTIVE: Quantitative measurements of vibrotactile and thermotactile perception thresholds (VPT and TPT, respectively) rely on responses from sensory receptors in the skin when mechanical or thermal stimuli are applied to the skin. The objective was to examine if there is a relation between skin thickness (epidermis and dermis) and VPT or TPT. METHODS: Perception thresholds were measured on the volar side of the fingertip on 148 male subjects, out of which 116 were manual workers exposed to hand-transmitted vibration and 32 were white-collar (office) workers. Skin thickness was measured using a high-frequency ultrasonic derma scanner system. RESULTS: The difference in age, perception thresholds and skin thickness between manual and office workers was small and non-significant except for the perception of cold, which was decreased by vibration exposure. Skin thickness for both subgroups was mean 0.57 mm (range 0.25-0.93 mm). Increased age was associated with decreased perception of warmth and vibration. Lifetime cumulative exposure to vibration, but not age, was associated with decreased perception of cold. CONCLUSION: > .05) was found between finger skin thickness in the range of about 0.1-1 mm and vibration perception threshold for test frequencies from 8 to 500 Hz and thermotactile perception thresholds for warmth and cold. Increasing age was associated with reduced perception of vibration and warmth. Vibration exposure was associated with decreased perception of cold. SIGNIFICANCE: Skin thickness is a factor that may affect the response from sensory receptors, e.g., due to mechanical attenuation and thermal insulation. Thus, to evaluate perception threshold measurements, it is necessary to know if elevated thresholds can be attributed to skin thickness. No previous studies have measured skin thickness as related to vibrotactile and thermotactile perception thresholds. This study showed no association between skin thickness and vibrotactile perception or thermotactile perception.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
There exists tremendous variation even within a given body site caused by factors such as age, gender, BMI, sun-damage, and experimental methodology, leading to coefficients of variation up to 40%.
“However, there exists tremendous variation even within a given body site caused by factors such as age, gender, BMI, sun-damage, and experimental methodology, leading to coefficients of variation up to 40% [139,140,141].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [139]
The fingertips have the thinnest skin, followed by the forearm, dorsal hand, cheek, and forehead.
“Overall, the literature has shown that the fingertips have the thinnest skin, followed by the forearm, dorsal hand, cheek, and forehead [139].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [139]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Method for quantitative estimation of thermal thresholds in patients.
Fruhstorfer, H., Lindblom, U., & Schmidt, W. C. (1976) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.39.11.1071 · Cited by 785 · see citing works
Sandby-Møller, J., Poulsen, T., & Wulf, H. C. (2003) · Acta Dermato-Venereologica · doi:10.1080/00015550310015419 · Cited by 737 · see citing works
Skin thickness of Korean adults
Lee, Y., & Hwang, K. (2002) · Surgical and Radiologic Anatomy · doi:10.1007/s00276-002-0034-5 · Cited by 475 · see citing works
Waller, J. M., & Maïbach, H. I. (2005) · Skin Research and Technology · doi:10.1111/j.0909-725x.2005.00151.x · Cited by 392 · see citing works
Gambichler, T., Matip, R., Moussa, G., Altmeyer, P. J., & Hoffmann, K. K. P. (2006) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2006.09.008 · Cited by 239 · see citing works
Age-related diurnal changes of dermal oedema: evaluation by high-frequency ultrasound
Gniadecka, M., Serup, J. V., & Søndergaard, J. (1994) · British Journal of Dermatology · doi:10.1111/j.1365-2133.1994.tb08588.x · Cited by 94 · see citing works
Lundborg, G., Dahlin, L. B., Lundström, R., et al. (1992) · Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery · doi:10.3109/02844319209015271 · Cited by 72 · see citing works
Self-citationVibrotactile perception threshold measurements for diagnosis of sensory neuropathy
Lundstr�m, R., Str�mberg, T., & Lundborg, G. (1992) · International Archives of Occupational and Environmental Health · doi:10.1007/bf00380910 · Cited by 68 · see citing works
Self-citationLundström, R. (2002) · International Archives of Occupational and Environmental Health · doi:10.1007/s004200100279 · Cited by 38 · see citing works
Self-citationNilsson, T. (2002) · International Archives of Occupational and Environmental Health · doi:10.1007/s004200100278 · Cited by 33 · see citing works
Self-citationThermal perception thresholds among young adults exposed to hand-transmitted vibration
Nilsson, T., Burström, L., Hagberg, M., & Lundström, R. (2008) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-007-0258-0 · Cited by 21 · see citing works
Self-citationQuantitative thermal perception thresholds relative to exposure to vibration
Nilsson, T., & Lundström, R. (2001) · Occupational and Environmental Medicine · doi:10.1136/oem.58.7.472 · Cited by 20 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
- Authors
- Lundström, R., Dahlqvist, H., Hagberg, M., & Nilsson, T.
- Affiliations
- Umeå University (SE)
- Karlstad University (SE)
- Sahlgrenska University Hospital (SE)
- Corresponding author
- Lundström, Ronnie
- Venue
- Clinical Neurophysiology Practice
- Publisher
- Elsevier BV
- Published
- 2018
- Volume
- 3
- Pages
- 33-39
- ISSN
- 2467-981X (ISSN-L)
- PMC
- PMC6133778
- OpenAlex
- W2785725478
- Cited by
- 30
- References
- 12
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 9 · 2023: 2 · 2022: 1 · 2021: 3 · 2020: 5 · 2018: 1
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Clinical Neurophysiology Practice (publishedVersion, cc-by-nc-nd)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- DiVA at Umeå University (Umeå University) (submittedVersion, other-oa)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Swedish Council for Health, Working Life and Welfare
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Effects of Vibration on Health
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Physical Sciences › Engineering › Aerospace Engineering › Human auditory perception and evaluation
- Keywords
- vibration perception threshold, hand-arm vibration, occupational vibration exposure, cold sensation, perceived warmth, blue-collar workers, office workers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review