Measuring local pH in electrochemistry
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Localized pH measurements are important in various areas of electrochemistry, from corrosion to bio-electrochemistry and electrocatalysis. Different techniques are available to perform these measurements and offer numerous possibilities in terms of spatial and temporal resolution, sensitivity, and precision. In this brief review we present the recent progress made and summarize the main techniques available for localized pH measurements in electrochemistry such as scanning probe techniques (SECM, SICM, SIET), laser (confocal) fluorescence microscopy, rotating ring-disc electrode (RRDE) voltammetry, and infra-red spectroscopy, among others.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthesis of clathrate cerium superhydride CeH9 at 80-100 GPa with atomic hydrogen sublattice
Salke, N. P., Davari Esfahani, M. M., Zhang, Y., Kruglov, I. A., Zhou, J., Wang, Y., Greenberg, E., Prakapenka, V. B., Liu, J., Oganov, A. R., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-12326-y · Cited by 1,004
Fluorescent bioimaging of pH: from design to applications
Hou, J.-T., Ren, W. X., Li, K., Seo, J., Sharma, A., Yu, X.-Q., & Kim, J. S. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00719h · Cited by 557
Wencel, D., Abel, T., & McDonagh, C. (2014) · Analytical Chemistry · doi:10.1021/ac4035168 · Cited by 541
Metal oxides based electrochemical pH sensors: Current progress and future perspectives
Manjakkal, L., Szwagierczak, D., & Dahiya, R. (2020) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.100635 · Cited by 481
Ooka, H., Figueiredo, M. C., & Koper, M. T. M. (2017) · Langmuir · doi:10.1021/acs.langmuir.7b00696 · Cited by 422
Self-citationScanning Electrochemical Microscopy
(2012) · CRC Press eBooks · doi:10.1201/b11850 · Cited by 346
Zhang, F., & Co, A. C. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201912637 · Cited by 298
Yang, K., Kas, R., & Smith, W. A. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b07000 · Cited by 288
pH Matters When Reducing CO2 in an Electrochemical Flow Cell
Zhang, Z., Melo, L., Jansonius, R. P., Habibzadeh, F., Grant, E. R., & Berlinguette, C. P. (2020) · ACS Energy Letters · doi:10.1021/acsenergylett.0c01606 · Cited by 266
Ayemoba, O., & Cuesta, A. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b07351 · Cited by 256
Cited by
Shih, A. J., Monteiro, M. C. O., Dattila, F., Pavesi, D., Philips, M., da Silva, A. H. M., Vos, R. E., Ojha, K., Park, S., van der Heijden, O., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00164-0 · Cited by 521
Self-citationReaction Environment Regulation for Electrocatalytic CO2 Reduction in Acids
Zeng, M., Fang, W., Cen, Y., Zhang, X., Hu, Y., & Xia, B. Y. (2024) · Angewandte Chemie International Edition · doi:10.1002/anie.202404574 · Cited by 213
Metadata
- Authors
- Monteiro, M. C. O., & Koper, M. T. M.
- Venue
- Current Opinion in Electrochemistry
- Publisher
- Elsevier BV
- Published
- 2021-02
- Volume
- 25
- Pages
- 100649
- ISSN
- 2451-9103 (ISSN-L)
- OpenAlex
- W3097148834
- Cited by
- 159
- References
- 33
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measuring local pH in electrochemistry. https://app.cochat.ai/papers/10.1016/j.coelec.2020.100649
- The paper
- Monteiro, M. C. O., & Koper, M. T. M. (2021). Measuring local pH in electrochemistry. Current Opinion in Electrochemistry. https://doi.org/10.1016/j.coelec.2020.100649
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.