CoChat

Combined adjustment of pH and ultrasound treatments modify techno-functionalities of pea protein concentrates

de Oliveira, Ana Paula Hanke, Omura, Michele Harumi, Barbosa, Éverton de Almeida Alves, Bressan, Gustavo Costa, Vieira, Érica Nascif Rufino, Coimbra, Jane Sélia dos Reis, de Oliveira, Eduardo Basílio · 2020 · Colloids and Surfaces A: Physicochemical and Engineering Aspects
Cited by 66

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Abstract Plant proteins, and particularly pea proteins, have become more and more crucial as ingredient for food industries, due to ecological concerns, health benefits and even religious reasons. Although literature reports addressing the use of high intensity ultrasound (HUS) to improve tecnho-functionalities of pea proteins at different pH can be found, such studies involved HUS power/time combinations corresponding to different total energy inputs. In this manner, it is still unclear if HUS energy rates received by proteins have an effect on their techno-functional properties, rather than the total energy. To shed light on this question, here we studied the effects of HUS energy rates on pea protein concentrates (PPCs), treated according to the HUS power/time binomials: 412.5 W/581.82 s, 487.5 W/492.31 s, 562.5 W/426.66 s, 637.5 W/376.47 s, 712.5 W/336.84 s (total energy input constant = 240 kJ), with pHs adjusted to 2.8, 4.3, 6.8, and without pH adjustment. None of the HUS/pH tratments harmed the in vitro diggestibility of PPCs, suggesting that proteins were nutritionally preserved. For all physicochemical properties assessed, different HUS power/time binomials triggered different results, at a given pH, indicating that the energy application rate may be indeed relevant for PPC ultrasonic processing. It is noteworthy that when using the HUS treatment 562.5 W/426.66 s, at pH 6,8, the emulsifying properties of PCC were greatly improved. On the other hand, whatever the HUS treatment, at pH 2.8, PPCs had both higher water dispersibility and better emulsifying properties. Weaker techno-functionalities were evidenced for PPCs at pH 4.3, although slightly differences due to different HUS power/time binomials were observed. All these results were detailed, discussed, and explained based on differences of exposed proteins’ hydrophobic surfaces, free -SH groups, dispersibility, ζ-potential, and average hydrodynamic diameters of protein particles in aqueous dispersions, submitted to different combined pH/HUS treatments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.colsurfa.2020.125156

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
de Oliveira, A. P. H., Omura, M. H., Barbosa, É. D. A. A., Bressan, G. C., Vieira, É. N. R., Coimbra, J. S. D. R., & de Oliveira, E. B.
Venue
Colloids and Surfaces A: Physicochemical and Engineering Aspects
Publisher
Elsevier BV
Published
2020-10
Volume
603
Pages
125156
ISSN
0927-7757 (ISSN-L)
OpenAlex
W3034712476
Cited by
66
References
8
FWCI
5.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.