Binary mixing of micelles using Pluronics for a nano-sized drug delivery system
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Pluronics with different structural compositions and properties are used for several applications, including drug delivery systems. We developed a binary mixing system with two Pluronics, L121/P123, as a nano-sized drug delivery carrier. The lamellar-forming Pluronic L121 (0.1 wt%) was incorporated with Pluronic P123 to produce nano-sized dispersions (in case of 0.1 and 0.5 wt% P123) with high stability due to Pluronic P123 and high solubilization capacity due to Pluronic L121. The binary systems were spherical and less than 200-nm diameter, with high thermodynamic stability (at least 2 weeks) in aqueous solution. The CMC of the binary system was located in the middle of the CMC of each polymer. In particular, the solubilization capacity of the binary system (0.1/0.1 wt%) was higher than mono-systems of P123. The main advantage of binary systems is overcoming limitations of mono systems to allow tailored mixing of block copolymers with different physicochemical characteristics. These nano-sized systems may have potential as anticancer drug delivery systems with simple preparation method, high stability, and high loading capacity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kabanov, A. V., & Alakhov, V. Y. (2002) · Critical Reviews in Therapeutic Drug Carrier Systems · doi:10.1615/critrevtherdrugcarriersyst.v19.i1.10 · Cited by 447
Kozlov, M. Y., Melik-Nubarov, N. S., Batrakova, E. V., & Kabanov, A. V. (2000) · Macromolecules · doi:10.1021/ma991634x · Cited by 322
Cited by
Polymeric micelles as drug delivery vehicles
Ahmad, Z., Shah, A., Siddiq, M., & Kraatz, H.-B. (2014) · RSC Adv. · doi:10.1039/c3ra47370h · Cited by 610
Recent progress in biomedical applications of pluronic (PF127): Pharmaceutical perspectives
Akash, M. S. H., & Rehman, K. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.04.032 · Cited by 394
Zhang, W., Shi, Y., Chen, Y., Ye, J., Sha, X., & Fang, X. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.12.039 · Cited by 368
Sayed, S., Elsayed, I., & Ismail, M. M. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2018.08.001 · Cited by 63
Fahmy, A. M., Hassan, M., El-Setouhy, D. A., Tayel, S. A., & Al-mahallawi, A. M. (2021) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2020.12.013 · Cited by 45
Metadata
- Authors
- Lee, E. S., Oh, Y. T., Youn, Y. S., Nam, M., Park, B., Yun, J., Kim, J. H., Song, H.-T., & Oh, K. T.
- Venue
- Colloids and Surfaces B: Biointerfaces
- Publisher
- Elsevier BV
- Published
- 2011-01
- Volume
- 82
- Issue
- 1
- Pages
- 190-195
- ISSN
- 0927-7765 (ISSN-L)
- OpenAlex
- W2118447321
- Cited by
- 124
- References
- 2
- FWCI
- 3.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Binary mixing of micelles using Pluronics for a nano-sized drug delivery system. https://app.cochat.ai/papers/10.1016/j.colsurfb.2010.08.033
- The paper
- Lee, E. S., Oh, Y. T., Youn, Y. S., Nam, M., Park, B., Yun, J., Kim, J. H., Song, H.-T., & Oh, K. T. (2011). Binary mixing of micelles using Pluronics for a nano-sized drug delivery system. Colloids and Surfaces B: Biointerfaces. https://doi.org/10.1016/j.colsurfb.2010.08.033
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.