The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
X-ray computed tomography of polymer composites
Open accessAbstract
The use of X-ray computed tomography (CT), exploiting both synchrotron and laboratory sources, has grown significantly over the last decade, driven primarily by improvements in spatial resolution, reduction in acquisition time and the increasing availability of laboratory X-ray CT systems. It is now able to provide highly accurate three-dimensional (3D) inspections of fibre architectures, manufacturing defects and in-service damage accumulation non-destructively, allowing the user to examine cross-sections that would previously have required laborious and skilled mechanical sectioning with the potential for inducing damage or loss of material. Further, by repeated acquisition of 3D images, it has opened new opportunities for time-lapse studies. This feature article reviews the technical aspects relating to the X-ray CT imaging of composites such as obtaining sufficient contrast, examination of thin panels, sample size/resolution issues, quantification of damage and defects, and image-based modelling. The capability of X-ray CT to provide important information is considered across applications ranging from manufacturing processes, through tensile and compression loading to fatigue and impact damage. The complementary advantages of laboratory and synchrotron X-ray CT are examined with a view to identify new opportunities and challenges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Statistical Distribution Function of Wide Applicability
Weibull, W. (1951) · Journal of Applied Mechanics · doi:10.1115/1.4010337 · Cited by 11,604
Henke, B. L., Gullikson, E. M., & Davis, J. C. (1993) · Atomic Data and Nuclear Data Tables · doi:10.1006/adnd.1993.1013 · Cited by 6,285
Phase-contrast imaging using polychromatic hard X-rays
Wilkins, S. W., Gureyev, T. E., Gao, D., Pogany, A., & Stevenson, A. W. (1996) · Nature · doi:10.1038/384335a0 · Cited by 1,766
Snigirev, A., Snigireva, I., Kohn, V., Kuznetsov, S., & Schelokov, I. (1995) · Review of Scientific Instruments · doi:10.1063/1.1146073 · Cited by 1,493
Maire, E., & Withers, P. J. (2014) · International Materials Reviews · doi:10.1179/1743280413y.0000000023 · Cited by 1,374
Self-citationX-ray phase imaging with a grating interferometer
Weitkamp, T., Diaz, A., David, C., Pfeiffer, F., Stampanoni, M., Cloetens, P., & Ziegler, E. (2005) · Optics Express · doi:10.1364/opex.13.006296 · Cited by 1,211
Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT
Sidky, E. Y., Kao, C.-M., & Pan, X. (2006) · Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · doi:10.3233/xst-2006-00155 · Cited by 1,091
Tensile failure of fibrous composites
ROSEN, B. W. (1964) · AIAA Journal · doi:10.2514/3.2699 · Cited by 730
Tensile failure of fibrous composites
ROSEN, B. (1964) · Aerospace Sciences Meeting · doi:10.2514/6.1964-73 · Cited by 651
Iassonov, P., Gebrenegus, T., & Tuller, M. (2009) · Water Resources Research · doi:10.1029/2009wr008087 · Cited by 628
Computed Tomography From Photon Statistics to Modern Cone-Beam CT
Mihailidis, D. N. (2009) · Medical Physics · doi:10.1118/1.3176026 · Cited by 583
Recent advances in X-ray microtomography applied to materials
Stock, S. R. (2008) · International Materials Reviews · doi:10.1179/174328008x277803 · Cited by 517
In Situ Experiments with X ray Tomography: an Attractive Tool for Experimental Mechanics
Buffiere, J. Y., Maire, E., Adrien, J., Masse, J. P., & Boller, E. (2010) · Experimental Mechanics · doi:10.1007/s11340-010-9333-7 · Cited by 500
X-ray microtomography of materials
Stock, S. R. (1999) · International Materials Reviews · doi:10.1179/095066099101528261 · Cited by 366
Evaluation of a microcomputed tomography system to study trabecular bone structure
Kuhn, J. L., Goldstein, S. A., Feldkamp, L. A., Goulet, R. W., & Jesion, G. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080608 · Cited by 336
Size effects in the testing of fibre-composite materials
Wisnom, M. R. (1999) · Composites Science and Technology · doi:10.1016/s0266-3538(99)00053-6 · Cited by 330
Materials Characterization Using Nondestructive Evaluation (NDE) Methods
(2016) · Elsevier eBooks · doi:10.1016/c2014-0-00661-2 · Cited by 234
The imaging of failure in structural materials by synchrotron radiation X-ray microtomography
Wu, S. C., Xiao, T. Q., & Withers, P. J. (2017) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2017.07.027 · Cited by 225
Self-citationNaouar, N., Vidal-Sallé, E., Schneider, J., Maire, É., & Boisse, P. (2014) · Composite Structures · doi:10.1016/j.compstruct.2014.04.026 · Cited by 220
In-Line Phase-Contrast X-ray Imaging and Tomography for Materials Science
Mayo, S. C., Stevenson, A. W., & Wilkins, S. W. (2012) · Materials · doi:10.3390/ma5050937 · Cited by 210
3D composite reinforcement meso F.E. analyses based on X-ray computed tomography
Naouar, N., Vidal-Salle, E., Schneider, J., Maire, E., & Boisse, P. (2015) · Composite Structures · doi:10.1016/j.compstruct.2015.07.005 · Cited by 201
Emerson, M. J., Jespersen, K. M., Dahl, A. B., Conradsen, K., & Mikkelsen, L. P. (2017) · Composites Part A Applied Science and Manufacturing · doi:10.1016/j.compositesa.2016.12.028 · Cited by 196
Tensile Strength of Unidirectionally Reinforced Composites — I
Batdorf, S. B. (1982) · Journal of Reinforced Plastics and Composites · doi:10.1177/073168448200100206 · Cited by 177
3D damage characterisation and the role of voids in the fatigue of wind turbine blade materials
Lambert, J., Chambers, A. R., Sinclair, I., & Spearing, S. M. (2012) · Composites Science and Technology · doi:10.1016/j.compscitech.2011.11.023 · Cited by 164
Aroush, D. R.-B., Maire, É., Gauthier, C., Youssef, S., Cloetens, P., & Wagner, H. D. (2005) · Composites Science and Technology · doi:10.1016/j.compscitech.2005.09.010 · Cited by 136
Yu, B., Blanc, R., Soutis, C., & Withers, P. J. (2015) · Composites Part A Applied Science and Manufacturing · doi:10.1016/j.compositesa.2015.09.001 · Cited by 125
Self-citationArtefacts in X-ray microtomography of materials
Davis, G. R., & Elliott, J. C. (2006) · Materials Science and Technology · doi:10.1179/174328406x114117 · Cited by 124
Zernike phase contrast in scanning microscopy with X-rays
Holzner, C., Feser, M., Vogt, S., Hornberger, B., Baines, S. B., & Jacobsen, C. J. (2010) · Nature Physics · doi:10.1038/nphys1765 · Cited by 124
Czabaj, M. W., Riccio, M. L., & Whitacre, W. W. (2014) · Composites Science and Technology · doi:10.1016/j.compscitech.2014.10.017 · Cited by 122
On the implementation of computed laminography using synchrotron radiation
Helfen, L., Myagotin, A., Mikulík, R., et al. (2011) · Review of Scientific Instruments · doi:10.1063/1.3596566 · Cited by 119
Sencu, R. M., Yang, Z., Wang, Y., Withers, P. J., Rau, C., Parson, A. L., & Soutis, C. (2016) · Composites Part A Applied Science and Manufacturing · doi:10.1016/j.compositesa.2016.09.010 · Cited by 114
Self-citationGarcea, S. C., Sinclair, I., Spearing, S. M., & Withers, P. J. (2017) · Composites Science and Technology · doi:10.1016/j.compscitech.2017.06.006 · Cited by 100
Self-citationTowards in-process x-ray CT for dimensional metrology
Warnett, J. M., Titarenko, V., Kiraci, E., Attridge, A., Lionheart, W. R. B., Withers, P. J., & Williams, M. A. (2016) · Measurement Science and Technology · doi:10.1088/0957-0233/27/3/035401 · Cited by 64
Self-citationRecent Advances in X-ray Cone-beam Computed Laminography
O’Brien, N. S., Boardman, R., Sinclair, I., & Blumensath, T. (2016) · Journal of X-Ray Science and Technology · doi:10.3233/xst-160581 · Cited by 64
Fiber bundle push-out test and image-based finite element simulation for 3D carbon/carbon composites
Sharma, R., Mahajan, P., & Mittal, R. K. (2012) · Carbon · doi:10.1016/j.carbon.2012.02.030 · Cited by 48
X-ray microtomography for materials characterization
Hanke, R., Fuchs, T. O. J., Salamon, M., & Zabler, S. (2016) · Elsevier eBooks · doi:10.1016/b978-0-08-100040-3.00003-1 · Cited by 41
Reh, A., Plank, B., Kastner, J., Groller, E. M., & Heinzl, C. (2012) · Computer Graphics Forum · doi:10.1111/j.1467-8659.2012.03111.x · Cited by 32
Cited by
Withers, P. J., Bouman, C., Carmignato, S., Cnudde, V., Grimaldi, D., Hagen, C. K., Maire, E., Manley, M., Du Plessis, A., & Stock, S. R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00015-4 · Cited by 1,079
Self-citationNon-destructive testing and evaluation of composite materials/structures: A state-of-the-art review
Wang, B., Zhong, S., Lee, T.-L., Fancey, K. S., & Mi, J. (2020) · Advances in Mechanical Engineering · doi:10.1177/1687814020913761 · Cited by 581
Non-destructive testing and evaluation of composite materials/structures: A state-of-the-art review
Wang, B., Zhong, S., Lee, T.-L., Fancey, K. S., & Mi, J. (2019) · Apollo (University of Cambridge) · doi:10.17863/cam.51343 · Cited by 444
Nsengiyumva, W., Zhong, S., Lin, J., Zhang, Q., Zhong, J., & Huang, Y. (2021) · Composite Structures · doi:10.1016/j.compstruct.2020.112951 · Cited by 325
Successes and challenges in non-destructive testing of aircraft composite structures
TOWSYFYAN, H., BIGURI, A., BOARDMAN, R., & BLUMENSATH, T. (2020) · Chinese Journal of Aeronautics · doi:10.1016/j.cja.2019.09.017 · Cited by 272
Metadata
- Authors
- Garcea, S. C., Wang, Y., & Withers, P. J.
- Venue
- Composites Science and Technology
- Publisher
- Elsevier BV
- Published
- 2018-03
- Volume
- 156
- Pages
- 305-319
- ISSN
- 0266-3538 (ISSN-L)
- OpenAlex
- W2765287370
- Cited by
- 719
- References
- 37
- FWCI
- 44.67
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.