The DOI matches its Crossref record.
On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation
Abstract
Coherent properties of the x-ray beam delivered at the ESRF allow the observation of very weak perturbations of the wave front, resulting in the phase contrast. A straightforward experimental setup for phase contrast imaging is proposed and used to record holographic images from organic samples of 10–100 μm at energy 10–50 keV with the contrast up to 50%–100%. The theory of phase contrast imaging is considered and some theoretical estimations are made to reveal the performance of the proposed technique in terms of resolution, sensitivity, geometrical requirements, and energy range applicability. It is found that for carbon-based fibers a detectable size with 2% contrast is 0.1 μm for 10 keV and −1 μm for 100 keV. It is demonstrated that the fine interference structure of the image is very sensitive to the shape, density variation, and internal structure of the sample. Some prospects for the practical use and future development of the new coherent techniques such as phase contrast microscopy, microtomography, holography, and interferometry at high energies are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
Pfeiffer, F., Weitkamp, T., Bunk, O., & David, C. (2006) · Nature Physics · doi:10.1038/nphys265 · Cited by 1,855
Observation of microstructure and damage in materials by phase sensitive radiography and tomography
Cloetens, P., Pateyron-Salomé, M., Buffière, J. Y., Peix, G., Baruchel, J., Peyrin, F., & Schlenker, M. (1997) · Journal of Applied Physics · doi:10.1063/1.364374 · Cited by 538
Tafforeau, P., Boistel, R., Boller, E., Bravin, A., Brunet, M., Chaimanee, Y., Cloetens, P., Feist, M., Hoszowska, J., Jaeger, J.-J., et al. (2006) · Applied Physics A · doi:10.1007/s00339-006-3507-2 · Cited by 456
Fast 3D reconstruction method for differential phase contrast X-ray CT
McCann, M. T., Nilchian, M., Stampanoni, M., & Unser, M. (2016) · Optics Express · doi:10.1364/oe.24.014564 · Cited by 28
Metadata
- Authors
- Snigirev, A., Snigireva, I., Kohn, V., Kuznetsov, S., & Schelokov, I.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1995-12-01
- Volume
- 66
- Issue
- 12
- Pages
- 5486-5492
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2053331261
- Cited by
- 1,493
- References
- 0
- FWCI
- 18.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation. https://app.cochat.ai/papers/10.1063/1.1146073
- The paper
- Snigirev, A., Snigireva, I., Kohn, V., Kuznetsov, S., & Schelokov, I. (1995). On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation. Review of Scientific Instruments. https://doi.org/10.1063/1.1146073
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.