CoChat

Highly sensitive and flexible piezoresistive sensor based on c-MWCNTs decorated TPU electrospun fibrous network for human motion detection

Li, Siming, Li, Ruiqing, González, Orianaisy Gelis, Chen, Tianjiao, Xiao, Xueliang · 2021 · Composites Science and Technology
Cited by 162

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Abstract Flexible and wearable pressure sensor with high sensitivity has aroused great attentions in recent years. In this work, a flexible piezoresistive pressure sensor was fabricated based on a kind of thermoplastic urethane (TPU) within electrospun fibrous network (TPUN), where the TPUN was decorated with c-MWCNTs successfully to realize the excellent conductivity. The novel piezoresistive pressure sensor exhibited a high sensitivity up to 2 kPa-1, a wide working pressure range of 10 kPa, a low hysteresis deviation (below 6%), a good structural stability and durability for more than 1000 cycles, and the distinguishment of various frequencies and pressures. Benefited from the excellent sensing performances and stable structure, a few demonstrations were performed to acquire human physiological signals such as various muscle activities and pulse, indicating the developed pressure sensor with a high potential uses in e-skins and wearable devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.compscitech.2020.108617

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 162

Metadata

Authors
Li, S., Li, R., González, O. G., Chen, T., & Xiao, X.
Venue
Composites Science and Technology
Publisher
Elsevier BV
Published
2021-02
Volume
203
Pages
108617
ISSN
0266-3538 (ISSN-L)
OpenAlex
W3111905307
Cited by
162
References
7
FWCI
5.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.