The DOI matches its Crossref record; 150 of the 152 references it cites were found in a registry or an index.
Optical and thermal performance of glazing units containing PCM in buildings: A review
Abstract
Abstract Glazing units are important for providing passive solar gain and air ventilation in buildings, but their thermal performance is very poor compared to other building components, which results that energy loss from building envelope becomes much more drastic when the glazing area is large. Incorporating phase change material (PCM) in the glazing unit is an effective approach to increase its thermal performance. The glazing unit containing PCM can absorb part of the solar radiation for thermal energy storage while letting the visible radiation enter the indoor ambient for daylighting, which results in reduction of the temperature fluctuations and improvement of the thermal comfort of indoor occupants. A lot of researchers investigated optical and thermal performance of window systems containing PCM in buildings. However, there is a lack of published research review including numerical methods of optical and thermal performance and physical parameters of PCM used in the glazing units, especially for the optical performance of glazing units containing PCM. The present work reviews the experimental and simulation researches on the optical and thermal performance of glazing units containing PCM and discusses the employed research methods, mathematical models and important conclusions drawn. Finally, the challenges and future works of glazing units containing PCM are addressed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Therefore, and bearing in mind that it has different melting points, it can be used to enhance indoor thermal performance by using it in double-glazed units, thereby reducing the energy demand of the building [28].”
From Latent thermal energy storage technologies and applications: A review (2020) · cites this paper as [28]
In the citing paper
“Eutectic phase change materials involve a combination of two or more types of phase change materials, which usually consist of organic-organic (Capric-laurie/Lauric palmitic/Myristic-stearic), inorganic-inorganic (LiOH-KOH/MgKCl 2 -KCl/BACl 2 -KCl-NaCl) and inorganic-organic (Napthalenebenzoicacid/Urea NH 4 Br) materials [28].”
From Latent thermal energy storage technologies and applications: A review (2020) · cites this paper as [28]
In the citing paper
“Some inevitable drawbacks of paraffin limit its application in practice, such as low thermal conductivity (about 0.2À0.4W/ m K and high volume expansion during phase transition [22,28].”
From Latent thermal energy storage technologies and applications: A review (2020) · cites this paper as [28]
In the citing paper
“Paraffin due to its crucial properties consisting of a high heat of fusion, fluctuated stage change temperature, high phase change enthalpy, zero super cooling characteristics, lower vapour pressure, and being chemically inert (without corrosion and toxicity), with constant conductivity cyclic stability has been applied for energy storage [26,28].”
From Latent thermal energy storage technologies and applications: A review (2020) · cites this paper as [28]
Citations
Cites
Barron, R. F. (1999) · CRC Press eBooks · doi:10.1201/b15230-9 · Cited by 3,537
A review on phase change energy storage: materials and applications
Farid, M. M., Khudhair, A. M., Razack, S. A. K., & Al-Hallaj, S. (2004) · Energy Conversion and Management · doi:10.1016/j.enconman.2003.09.015 · Cited by 3,097
Khudhair, A. M., & Farid, M. M. (2003) · Energy Conversion and Management · doi:10.1016/s0196-8904(03)00131-6 · Cited by 1,398
PCM thermal storage in buildings: A state of art
Tyagi, V. V., & Buddhi, D. (2005) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2005.10.002 · Cited by 1,137
Aerogel insulation for building applications: A state-of-the-art review
Baetens, R., Jelle, B. P., & Gustavsen, A. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.12.012 · Cited by 1,094
A review on phase change material (PCM) for sustainable passive cooling in building envelopes
Akeiber, H. J., Nejat, P., Majid, M. Z. A., Wahid, M. B. A., Jomehzadeh, F., Famileh, I. Z., Calautit, J. K., Hughes, B. R., & Zaki, S. A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.03.036 · Cited by 1,082
Phase change materials for building applications: A state-of-the-art review
Baetens, R., Jelle, B. P., & Gustavsen, A. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.03.026 · Cited by 1,048
Toward aerogel based thermal superinsulation in buildings: A comprehensive review
Cüce, E., Cuce, P. M., Wood, C. J., & Riffat, S. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.03.017 · Cited by 806
Iguchi, M., & Ilegbusi, O. J. (2013) · Springer eBooks · doi:10.1007/978-4-431-54020-5_6 · Cited by 710
Fenestration of today and tomorrow: A state-of-the-art review and future research opportunities
Jelle, B. P., Hynd, A., Gustavsen, A., Arasteh, D., Goudey, H., & Hart, R. (2011) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2011.08.010 · Cited by 554
A review of performance of zero energy buildings and energy efficiency solutions
Belussi, L., Barozzi, B., Bellazzi, A., Danza, L., Devitofrancesco, A., Fanciulli, C., Ghellere, M., Guazzi, G., Meroni, I., Salamone, F., et al. (2019) · Journal of Building Engineering · doi:10.1016/j.jobe.2019.100772 · Cited by 470
Rezaei, S. D., Shannigrahi, S. R., & Ramakrishna, S. (2016) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2016.08.026 · Cited by 459
Pandey, A. K., Hossain, M. S., Tyagi, V. V., Rahim, N. A., Selvaraj, J. A.-L., & Sarı, A. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.09.043 · Cited by 426
A state-of-the-art review on innovative glazing technologies
Cüce, E., & Riffat, S. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.08.084 · Cited by 397
Review of PCM based cooling technologies for buildings
Osterman, E., Tyagi, V. V., Butala, V., Rahim, N. A., & Stritih, U. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.03.022 · Cited by 351
Thermal Energy Storage and Phase Change Materials: An Overview
Demirbas, M. F. (2006) · Energy Sources Part B Economics Planning and Policy · doi:10.1080/009083190881481 · Cited by 330
Živković, B., & FUJII, I. (2001) · Solar Energy · doi:10.1016/s0038-092x(00)00112-2 · Cited by 298
Passive thermal control in residential buildings using phase change materials
Kenisarin, M. M., & Mahkamov, K. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.10.128 · Cited by 296
Scaling theory of melting with natural convection in an enclosure
Jany, P., & Bejan, A. (1988) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(88)90065-8 · Cited by 281
Energy and economic analysis of building integrated with PCM in different cities of China
Mi, X., Liu, R., Cui, H., Memon, S. A., Xing, F., & Lo, T. Y. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.05.032 · Cited by 268
Innovative solar windows for cooling-demand climate
Chow, T. T., Li, C., & Lin, Z. (2009) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2009.09.004 · Cited by 260
Sarı, A., Alkan, C., & Bilgin, C. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.09.047 · Cited by 260
Ramakrishnan, S., Wang, X., Sanjayan, J., & Wilson, J. (2017) · Applied Energy · doi:10.1016/j.apenergy.2016.04.084 · Cited by 241
Marín, P. E., Saffari, M., de Gracia, Á., Zhu, X., Farid, M. M., Cabeza, L. F., & Ushak, S. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.08.007 · Cited by 223
Khadiran, T., Hussein, M. Z., Zainal, Z., & Rusli, R. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.081 · Cited by 221
Fang, X., Fan, L., Ding, Q. W., Yao, X.-L., Wu, Y., Hou, J.-F., Wang, X., Yu, Z., Cheng, G.-H., & Hu, Y.-C. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.01.016 · Cited by 213
Self-citationExperimental performance evaluation of aerogel glazing systems
Buratti, C., & Moretti, E. (2012) · Applied Energy · doi:10.1016/j.apenergy.2011.12.055 · Cited by 207
A review of passive envelope measures for improved building energy efficiency in the UAE
Friess, W. A., & Rakhshan, K. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.01.026 · Cited by 199
Lv, P., Liu, C., & Rao, Z. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.08.147 · Cited by 196
Self-citationGhosh, A., & Norton, B. (2018) · Renewable Energy · doi:10.1016/j.renene.2018.04.038 · Cited by 196
Guarino, F., Athienitis, A. K., Cellura, M., & Bastien, D. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.10.046 · Cited by 192
Nghana, B., & Tariku, F. A. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.01.023 · Cited by 186
Energy investigation of glazed windows containing Nano-PCM in different seasons
Li, D., Wu, Y., Liu, C., Zhang, G., & Arıcı, M. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.07.015 · Cited by 182
Self-citationImproving thermal comfort conditions by means of PCM glazing systems
Goia, F., Perino, M., & Serra, V. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.01.029 · Cited by 178
Experimental analysis of the energy performance of a full-scale PCM glazing prototype
Goia, F., Perino, M., & Serra, V. (2014) · Solar Energy · doi:10.1016/j.solener.2013.12.002 · Cited by 178
PCM-facade-panel for daylighting and room heating
Weinläder, H., Beck, A., & Fricke, J. (2004) · Solar Energy · doi:10.1016/j.solener.2004.04.013 · Cited by 176
Literature review on the use of phase change materials in glazing and shading solutions
Silva, T., Vicente, R., & Rodrigues, F. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.07.201 · Cited by 175
Berardi, U., & Soudian, S. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2018.12.016 · Cited by 174
Peng, J., Lu, L., & Yang, H. (2013) · Solar Energy · doi:10.1016/j.solener.2013.08.031 · Cited by 173
Comparison between PCM filled glass windows and absorbing gas filled windows
Ismail, K. A. R., Salinas, C. T., & Henríquez, J. R. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2007.05.005 · Cited by 170
The optimal thermo-optical properties and energy saving potential of adaptive glazing technologies
Favoino, F., Overend, M., & Jin, Q. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.05.065 · Cited by 159
Mehrali, M., Latibari, S. T., Mehrali, M., Mahlia, T. M. I., Sadeghinezhad, E., & Metselaar, H. S. C. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.08.100 · Cited by 155
Experimental and numerical investigations of the optical and thermal aspects of a PCM-glazed unit
Gowreesunker, B. L., Stanković, S. B., Tassou, S. A., & Kyriacou, P. A. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.02.032 · Cited by 155
A numerical model to evaluate the thermal behaviour of PCM glazing system configurations
Goia, F., Perino, M., & Haase, M. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.07.036 · Cited by 150
Zhong, K., Li, S., Sun, G., Li, S., & Zhang, X. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.05.014 · Cited by 150
Li, D., Li, Z., Zheng, Y., Liu, C., Hussein, A. K., & Liu, X. (2016) · Solar Energy · doi:10.1016/j.solener.2016.03.039 · Cited by 149
Self-citationFlow and heat transfer in double, triple and quadruple pane windows
Arıcı, M., Karabay, H., & Kan, M. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.10.043 · Cited by 148
Self-citationUsing phase change materials in window shutter to reduce the solar heat gain
Alawadhi, E. M. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.12.009 · Cited by 141
Thermally effective windows with moving phase change material curtains
Ismail, K. A. R., & Henríquez, J. R. (2001) · Applied Thermal Engineering · doi:10.1016/s1359-4311(01)00058-8 · Cited by 140
Han, J., Lu, L., & Yang, H. (2010) · Applied Energy · doi:10.1016/j.apenergy.2010.05.025 · Cited by 135
Soares, N., Martins, C., Gonçalves, M., Santos, P., da Silva, L. S., & Costa, J. J. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.10.021 · Cited by 134
Spectral and angular solar properties of a PCM-filled double glazing unit
Goia, F., Zinzi, M., Carnielo, E., & Serra, V. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.11.019 · Cited by 128
Energy performance and economic analysis of a TIM-PCM wall under different climates
Souayfane, F., Biwolé, P. H., Fardoun, F., & Achard, P. (2018) · Energy · doi:10.1016/j.energy.2018.12.116 · Cited by 127
Li, S., Sun, G., Zou, K., & Zhang, X. (2016) · Sustainable Cities and Society · doi:10.1016/j.scs.2016.08.014 · Cited by 126
Li, D., Wu, Y., Zhang, G., Arıcı, M., Liu, C., & Wang, F. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.04.015 · Cited by 125
Self-citationSilva, T., Vicente, R., Amaral, C., & Figueiredo, A. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.06.126 · Cited by 121
Li, S., Zhong, K., Zhou, Y., & Zhang, X. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.09.054 · Cited by 120
Perspective of aerogel glazings in energy efficient buildings
Gao, T., Ihara, T., Grynning, S., Jelle, B. P., & Lien, A. G. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.10.001 · Cited by 119
Thermal characteristics of water-flow double-pane window
Chow, T. T., Li, C., & Lin, Z. (2010) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2010.10.006 · Cited by 109
Liu, C., Wu, Y., Zhu, Y., Li, D., & Ma, L. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.10.069 · Cited by 107
Self-citationParametric study on composite and PCM glass systems
Ismail, K. A. R., & Henríquez, J. R. (2002) · Energy Conversion and Management · doi:10.1016/s0196-8904(01)00083-8 · Cited by 107
Li, S., Zou, K., Sun, G., & Zhang, X. (2018) · Sustainable Cities and Society · doi:10.1016/j.scs.2018.01.020 · Cited by 107
Silva, T., Vicente, R., Rodrigues, F., Samagaio, A., & Cardoso, C. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.11.053 · Cited by 103
Khan, Z., Khan, Z. A., & Tabeshf, K. (2016) · Energy Conversion and Management · doi:10.1016/j.enconman.2016.09.030 · Cited by 101
Arıcı, M., & Kan, M. (2014) · Renewable Energy · doi:10.1016/j.renene.2014.10.004 · Cited by 100
Self-citationHammarberg, E., & Roos, A. (2003) · Thin Solid Films · doi:10.1016/s0040-6090(03)00986-6 · Cited by 97
Li, D., Wu, Y., Liu, C., Zhang, G., & Arıcı, M. (2018) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2018.04.152 · Cited by 97
Self-citationKara, Y. A., & Seyhan, A. K. (2012) · Solar Energy · doi:10.1016/j.solener.2012.05.012 · Cited by 95
Effect of PCM thickness and melting temperature on thermal performance of double glazing units
Liu, C., Wu, Y., Li, D., Zhou, Y., Wang, Z., & Liu, X. (2017) · Journal of Building Engineering · doi:10.1016/j.jobe.2017.04.005 · Cited by 94
Self-citationSilva, T., Vicente, R., Rodrigues, F., Samagaio, A., & Cardoso, C. (2015) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.03.059 · Cited by 93
Review of free cooling system using phase change material for building
Kamali, S. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.05.021 · Cited by 93
López, T. G., & Gimenez-Molina, C. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.10.008 · Cited by 92
Low-emissivity coating of amorphous diamond-like carbon/Ag-alloy multilayer on glass
Chiba, K., Takahashi, T., Kageyama, T., & Oda, H. (2004) · Applied Surface Science · doi:10.1016/j.apsusc.2004.10.046 · Cited by 92
Gomes, M. G., Santos, A. J., & Rodrigues, A. M. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.09.003 · Cited by 91
Synthesis of window glazing coated with silica aerogel films via ambient drying
Kim, G.-S., & Hyun, S. (2003) · Journal of Non-Crystalline Solids · doi:10.1016/s0022-3093(03)00027-9 · Cited by 91
Huang, Y. J., & Niu, J. (2015) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2015.06.053 · Cited by 91
Liu, M., Wittchen, K. B., & Heiselberg, P. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.02.003 · Cited by 87
Singh, R., Lazarus, I. J., & Kishore, V. V. N. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.10.007 · Cited by 86
The function of solar absorbing window as water-heating device
Chow, T. T., Li, C., & Lin, Z. (2010) · Building and Environment · doi:10.1016/j.buildenv.2010.10.027 · Cited by 86
Berthou, Y., Biwolé, P. H., Achard, P., Sallee, H., Tantot-Neirac, M., & Jay, F. (2015) · Solar Energy · doi:10.1016/j.solener.2015.03.038 · Cited by 85
Numerical analysis on thermal performance of a PCM-filled double glazing roof
Liu, C., Zhou, Y., Li, D., Meng, F., Zheng, Y., & Liu, X. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.05.002 · Cited by 84
Self-citationLi, D., Ma, T., Liu, C., Zheng, Y., Wang, Z., & Liu, X. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.03.036 · Cited by 83
Self-citationPerformance investigation of heat insulation solar glass for low-carbon buildings
Cüce, E., Young, C.-H., & Riffat, S. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.09.021 · Cited by 79
Thermal performance of non-ventilated multilayer glazing facades filled with phase change material
Liu, C., Zhang, G., Arıcı, M., Bian, J., & Li, D. (2018) · Solar Energy · doi:10.1016/j.solener.2018.11.044 · Cited by 77
Self-citationOptimizing windows for enhancing daylighting performance and energy saving
Alhagla, K., Mansour, A., & Elbassuoni, R. (2019) · Alexandria Engineering Journal · doi:10.1016/j.aej.2019.01.004 · Cited by 77
Hu, Y. B., Heiselberg, P., Johra, H., & Guo, R. (2019) · Renewable Energy · doi:10.1016/j.renene.2019.05.115 · Cited by 76
Characterization of the optical properties of a PCM glazing system
Goia, F., Zinzi, M., Carnielo, E., & Serra, V. (2012) · Energy Procedia · doi:10.1016/j.egypro.2012.11.051 · Cited by 76
Lachheb, M., Karkri, M., Albouchi, F., Mzali, F., & Nasrallah, S. B. (2014) · Energy Conversion and Management · doi:10.1016/j.enconman.2014.03.021 · Cited by 74
Monitoring results of an interior sun protection system with integrated latent heat storage
Weinläder, H., Koerner, W., & Heidenfelder, M. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.06.007 · Cited by 74
Super insulated aerogel windows: Impact on daylighting and thermal performance
Garnier, C., Muneer, T., & McCauley, L. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.08.009 · Cited by 73
Solar heat gain coefficient of water flow glazings
Sierra, P., & Ramos, J. A. H. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.01.032 · Cited by 73
Li, Y., Darkwa, J., Kokogiannakis, G., & Su, W. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.113376 · Cited by 72
Thermal behavior of a translucent superinsulated latent heat energy storage wall in summertime
Souayfane, F., Biwolé, P. H., & Fardoun, F. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.02.119 · Cited by 71
Soares, N., Gaspar, A. R., Santos, P., & Costa, J. J. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.01.003 · Cited by 71
Li, D., Zheng, Y., Liu, C., Qi, H., & Liu, X. (2016) · Sustainable Cities and Society · doi:10.1016/j.scs.2016.02.004 · Cited by 68
Self-citationHeat insulation solar glass and application on energy efficiency buildings
Young, C.-H., Chen, Y., & Chen, P. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.04.012 · Cited by 67
Goia, F., Bianco, L., Cascone, Y., Perino, M., & Serra, V. (2014) · Energy Procedia · doi:10.1016/j.egypro.2014.02.144 · Cited by 64
Liu, C., Wu, Y., Li, D., Ma, T., Hussein, A. K., & Zhou, Y. (2017) · Journal of Building Physics · doi:10.1177/1744259117708734 · Cited by 64
Self-citationInvestigations of 6-pane glazing: Properties and possibilities
Kralj, A., Drev, M., Žnidaršič, M., Černe, B., Hafner, J., & Jelle, B. P. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.02.033 · Cited by 64
Sun, X., Zhang, Q., Medina, M. A., Lee, K. O., & Liao, S. (2016) · Energy Conversion and Management · doi:10.1016/j.enconman.2016.04.096 · Cited by 63
Gorantla, K. K., Shaik, S., Kumar, V., Kim, K., & Ashok Babu, T. P. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.05.054 · Cited by 63
Cappelletti, F., Prada, A., Romagnoni, P., & Gasparella, A. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.10.022 · Cited by 62
Han, Y., & Taylor, J. E. (2016) · Sustainable Cities and Society · doi:10.1016/j.scs.2016.03.001 · Cited by 62
Barzin, R., Chen, J. J. J., Young, B. R., & Farid, M. M. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.11.016 · Cited by 61
Influence of PCM design parameters on thermal and optical performance of multi-layer glazed roof
Liu, C., Wu, Y., Bian, J., Li, D., & Liu, X. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.12.012 · Cited by 61
Self-citationSouayfane, F., Biwolé, P. H., & Fardoun, F. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.11.026 · Cited by 60
Duraković, B., & Mešetović, S. (2018) · Sustainable Cities and Society · doi:10.1016/j.scs.2018.12.003 · Cited by 60
Xamán, J., Olazo-Gómez, Y., Zavala-Guillén, I., Hernández–Pérez, I., Ortegón-Aguilar, J., & Hinojosa, J. F. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.08.156 · Cited by 57
Effect of design configurations on water flow window performance
Chow, T. T., & Lyu, Y. (2017) · Solar Energy · doi:10.1016/j.solener.2017.06.050 · Cited by 56
Optical, thermal, and energy performance of advanced polycarbonate systems with granular aerogel
Moretti, E., Zinzi, M., Merli, F., & Buratti, C. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.01.057 · Cited by 55
Manikandan, S., & Rajan, K. S. (2017) · Energy Conversion and Management · doi:10.1016/j.enconman.2017.01.033 · Cited by 54
Ziasistani, N., & Fazelpour, F. (2019) · Solar Energy · doi:10.1016/j.solener.2019.05.040 · Cited by 54
López, T. G., & Gimenez-Molina, C. (2012) · Applied Energy · doi:10.1016/j.apenergy.2012.06.055 · Cited by 54
Vidalain, G., Gosselin, L., & Lacroix, M. (2008) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2008.09.020 · Cited by 53
Low-emitting transparent coatings based on tin doped indiumoxide applied via a sol–gel routine
Reidinger, M., Rydzek, M., Scherdel, C., Arduini-Schuster, M., & Manara, J. (2008) · Thin Solid Films · doi:10.1016/j.tsf.2008.11.078 · Cited by 53
Optical properties of a liquid paraffin-filled double glazing unit
Li, D., Zheng, Y., Li, Z., & Qi, H. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.09.039 · Cited by 51
Self-citationThermal performance of a room with a double glazing window using glazing available in Mexican market
Aguilar, J. O., Xamán, J., Olazo-Gómez, Y., Hernández-López, I. O., Becerra, G., & Jaramillo-Salgado, O. A. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.03.083 · Cited by 51
Impact of convection on thermal performance of aerogel granulate glazing systems
Ihara, T., Grynning, S., Gao, T., Gustavsen, A., & Jelle, B. P. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.12.001 · Cited by 50
Lyu, Y., Chow, T. T., & Wang, J. (2018) · Energy · doi:10.1016/j.energy.2018.05.140 · Cited by 47
Barzin, R., Chen, J. J. J., Young, B. R., & Farid, M. M. (2021) · CRC Press eBooks · doi:10.1201/9780367567699-17 · Cited by 45
Carlos, J. S., & Corvacho, H. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.11.002 · Cited by 44
Goia, F., & Boccaleri, E. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.03.007 · Cited by 44
Parametric investigations of using a PCM curtain for energy efficient buildings
Wang, Q., & Zhao, C. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.02.024 · Cited by 39
Sun, Y., Liang, R., Wu, Y., Wilson, R., & Rutherford, P. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.10.026 · Cited by 39
Self-citationAsdrubali, F., & Baldinelli, G. (2009) · Building Simulation · doi:10.1007/s12273-009-9112-5 · Cited by 38
Subjective reactions to daylight in rooms: Effect of using low-emittance coatings on windows
Bülow-Hübe, H. (1995) · Lighting Research & Technology · doi:10.1177/14771535950270010601 · Cited by 38
Experimental and Numerical Research of the Thermal Properties of a PCM Window Panel
Koláček, M., Charvátová, H., & Sehnálek, S. (2017) · Sustainability · doi:10.3390/su9071222 · Cited by 37
Reflectance Modulation of Transparent Multilayer Thin Films for Energy Efficient Window Applications
Han, K., & Kim, J. H. (2011) · Materials Letters · doi:10.1016/j.matlet.2011.05.006 · Cited by 35
Bianco, L., Komerska, A., Cascone, Y., Serra, V., Zinzi, M., Carnielo, E., & Ksionek, D. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.12.015 · Cited by 33
Tükel, M., Mumcuoğlu, K., Arıcı, M., & Karabay, H. (2018) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2018.11.089 · Cited by 32
Self-citationCarbonari, A., Fioretti, R., Naticchia, B., & Principi, P. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.11.022 · Cited by 31
Xamán, J., Olazo-Gómez, Y., Chávez, Y., Hinojosa, J. F., Hernández–Pérez, I., Hernández-López, I. O., & Zavala-Guillén, I. (2016) · Renewable Energy · doi:10.1016/j.renene.2016.03.055 · Cited by 31
Annual thermal evaluation of a double pane window using glazing available in the Mexican market
González-Julián, E., Xamán, J., Moraga, N. O., Chávez, Y., Zavala-Guillén, I., & Simá, E. (2018) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2018.07.053 · Cited by 31
Chernousov, A. A., & Chan, B. Y. B. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.02.054 · Cited by 30
Pichatwatana, K., Wang, F., Roaf, S., & Anunnathapong, M. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.05.007 · Cited by 29
Li, Y., Darkwa, J., & Su, W. (2019) · Energy Procedia · doi:10.1016/j.egypro.2019.01.688 · Cited by 26
Soares, N., Costa, J. J., Samagaio, A., & Vicente, R. (2013) · Journal of Building Physics · doi:10.1177/1744259113496388 · Cited by 26
Ismail, K. A. R., & Salinas, C. T. (2006) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2006.01.051 · Cited by 25
Zheng, C., Wu, P., Costanzo, V., Wang, Y., & Yang, X. (2017) · Procedia Engineering · doi:10.1016/j.proeng.2017.10.089 · Cited by 24
Study of the optical properties of AlN/ZrN/AlN low-e coating
Re, M. D., Gouttebaron, R., Dauchot, J. P., & Hecq, M. (2004) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2003.10.093 · Cited by 23
Dynamic thermal simulation of a glass-covered semi-outdoor space with roof evaporative cooling
Pagliarini, G., & Rainieri, S. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.10.027 · Cited by 22
Wang, D., Liu, Y., Wang, Y., Zhang, Q., & Liu, J. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.11.047 · Cited by 22
Zhang, Y., Wang, X., Zhang, Y., & Zhuo, S. (2016) · Energy · doi:10.1016/j.energy.2016.08.062 · Cited by 22
Research phosphate glass on turning sunlight into red light for glass greenhouse
Ming, C., Song, F., An, L., & Ren, X. (2014) · Materials Letters · doi:10.1016/j.matlet.2014.08.149 · Cited by 19
Comparative performance analysis of Vacuum Insulation Panels in thermal window shutters
Hashemi, A., Alam, M., & Ip, K. (2019) · Energy Procedia · doi:10.1016/j.egypro.2018.11.249 · Cited by 15
Liu, C., Zheng, Y., Li, D., Qi, H., & Liu, X. (2016) · Procedia Engineering · doi:10.1016/j.proeng.2016.08.369 · Cited by 14
Self-citationInvestigations on thermal and optical performances of a glazing roof with PCM layer
Liu, C., Wu, Y., Li, D., Ma, T., & Liu, X. (2017) · International Journal of Energy Research · doi:10.1002/er.3775 · Cited by 12
Self-citationBroadband emission from Ce3+/Mn2+/Yb3+ tri-doped oxyfluoride glasses for glass greenhouse
Wang, W., Huang, Z., Gao, H., Cheng, X., & Mao, Y. (2016) · Optical Materials · doi:10.1016/j.optmat.2016.10.037 · Cited by 11
The development of novel window systems towards low carbon buildings
Hao-yang, L. (2012) · UPT. Syiah Kuala University Library (Syiah Kuala University) · Cited by 8
INVESTIGATIONS ON TiO2 AND Ag BASED SINGLE AND MULTILAYER FILMS FOR WINDOW GLAZINGS
Hasan, M. M. U., Malek, A. B. M. A., Haseeb, A. S. M. A., & Masjuki, H. H. (2010) · Cited by 7
Research works printed but not linked: 3
- Zhong, 2014, Dynamic heat transfer characteristics of PCM-filled glass window and hollow glass window, CIESC J., 65, 114
- Mohammad, 2017, Thermal performance evaluation of low-E coated building glazing systems, Naqshejahan, 6, 025
- Kolacek, 2017, Experimental and numerical research of the thermal properties of a PCM window panel, Sustainability, 9, 1, 10.3390/su9071222 · DOI
Cited by
Latent thermal energy storage technologies and applications: A review
Jouhara, H., Żabnieńska-Góra, A., Khordehgah, N., Ahmad, D., & Lipinski, T. (2020) · International Journal of Thermofluids · doi:10.1016/j.ijft.2020.100039 · Cited by 543
“Therefore, and bearing in mind that it has different melting points, it can be used to enhance indoor thermal performance by using it in double-glazed units, thereby reducing the energy demand of the building [28].”
BackgroundMethodInfluentialHassan, F., Jamil, F., Hussain, A., Ali, H. M., Janjua, M. M., Khushnood, S., Farhan, M., Altaf, K., Said, Z., & Li, C. (2022) · Sustainable Energy Technologies and Assessments · doi:10.1016/j.seta.2021.101646 · Cited by 283
Zhang, S., Ocłoń, P., Klemeš, J. J., Michorczyk, P., Pielichowska, K., & Pielichowski, K. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112560 · Cited by 275
Rathore, P. K. S., Gupta, N. K., Yadav, D., Shukla, S. K., & Kaul, S. (2022) · Sustainable Cities and Society · doi:10.1016/j.scs.2022.103690 · Cited by 268
Nundy, S., Mesloub, A., Alsolami, B. M., & Ghosh, A. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2021.126854 · Cited by 254
Metadata
- Authors
- Li, D., Wu, Y., Wang, B., Liu, C., & Arıcı, M.
- Affiliations
- Northeast Petroleum University (CN)
- Kocaeli Üniversitesi (TR)
- Corresponding author
- Li, Dong
- Venue
- Construction and Building Materials
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 233
- Pages
- 117327
- ISSN
- 0950-0618 (ISSN-L)
- OpenAlex
- W2981757296
- Cited by
- 216
- References
- 152
- Citations by year
- 2026: 12 · 2025: 19 · 2024: 38 · 2023: 36 · 2022: 26 · 2021: 53 · 2020: 32
- FWCI
- 15.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Construction and Building Materials (publishedVersion)
- Kocaeli Üniversitesi - AVESİS (submittedVersion)
- Funders
- Northeast Petroleum University
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Phase Change Materials Research
- Physical Sciences › Engineering › Building and Construction › Solar Energy Systems and Technologies
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- phase change materials, glazing units, windows, optical performance, thermal performance, solar energy storage, daylighting, thermal comfort, thermal simulation model
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.