Corrosion behavior of biodegradable metals in two different simulated physiological solutions: Comparison of Mg, Zn and Fe
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Abstract Bio-absorbable metals have been proposed to overcome the limitations of permanent implant materials, particularly the risk of chronic inflammation and secondary surgery for removal after healing. The most researched bio-absorbable metal is magnesium, followed by iron and zinc, but there is little work comparing the different metals under the same experimental conditions. Herein, degradation performance of Mg/Zn/Fe was investigated via immersion test (28 days) and electrochemical tests under two buffer systems, simulated body fluid solution (SBF) and Dulbecco’s Modified Eagle’s cell culture medium (DMEM). Corrosion rate was initially slower in DMEM for all metals, Mg showed the fastest corrosion rate in both SBF and DMEM. The influence of the electrolyte on the corrosion behaviour was strongest for Mg. Importantly, the ranking of the corrosion rate of the three metals changes with immersion time. Noteworthy is a strong increase of corrosion resistance of Mg with time during the first 24 h of immersion. Corrosion morphology and corrosion products were characterized with SEM, EDS, FTIR, XPS and XRD. In general, the corrosion product layers are much more uniform in DMEM, besides, the insoluble corrosion product/precipitation consisted of metallic oxides/hydroxides, phosphates and carbonates. Slower corrosion rate in DMEM solution can therefore be due to formation of a more protective precipitate layer, adsorbed amino acids, and absence of Tris-HCl that accelerates corrosion in SBF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Investigation of multiplet splitting of Fe 2p XPS spectra and bonding in iron compounds
Grosvenor, A. P., Kobe, B. A., Biesinger, M. C., & McIntyre, N. S. (2004) · Surface and Interface Analysis · doi:10.1002/sia.1984 · Cited by 3,725
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Bunney, P. E., Zink, A. N., Holm, A. A., Billington, C. J., & Kotz, C. M. (2017) · Physiology & Behavior · doi:10.1016/j.physbeh.2017.03.040 · Cited by 2,104
The history of biodegradable magnesium implants: A review☆
Witte, F. (2010) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.02.028 · Cited by 1,860
Degradable biomaterials based on magnesium corrosion
Witte, F., Hort, N., Vogt, C., Cohen, S., Kainer, K. U., Willumeit, R., & Feyerabend, F. (2008) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2009.04.001 · Cited by 1,820
Kambe, T., Tsuji, T., Hashimoto, A., & Itsumura, N. (2015) · Physiological Reviews · doi:10.1152/physrev.00035.2014 · Cited by 1,158
Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable Stents
Bowen, P. K., Drelich, J., & Goldman, J. (2013) · Advanced Materials · doi:10.1002/adma.201300226 · Cited by 928
In vitro studies of biomedical magnesium alloys in a simulated physiological environment: A review
Xin, Y., Hu, T., & Chu, P. K. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.12.004 · Cited by 729
Zinc-based alloys for degradable vascular stent applications
Mostaed, E., Sikora-Jasinska, M., Drelich, J. W., & Vedani, M. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.03.005 · Cited by 565
Biodegradable Mg and Mg alloys: Corrosion and biocompatibility
Virtanen, S. (2011) · Materials Science and Engineering: B · doi:10.1016/j.mseb.2011.05.028 · Cited by 423
Self-citationZinc-based biomaterials for regeneration and therapy
Su, Y., Cockerill, I., Wang, Y., Qin, Y.-X., Chang, L., Zheng, Y., & Zhu, D. (2019) · Trends in biotechnology · doi:10.1016/j.tibtech.2018.10.009 · Cited by 417
Yang, H., Wang, C., Liu, C., Chen, H., Wu, Y., Han, J., Jia, Z., Lin, W., Zhang, D., Li, W., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.08.022 · Cited by 399
Effect of inorganic salts, amino acids and proteins on the degradation of pure magnesium in vitro
Yamamoto, A., & Hiromoto, S. (2009) · Materials Science and Engineering: C · doi:10.1016/j.msec.2008.12.015 · Cited by 368
Magnesium salts and oxide: an XPS overview
Ardizzone, S., Bianchi, C. L., Fadoni, M., & Vercelli, B. (1997) · Applied Surface Science · doi:10.1016/s0169-4332(97)00180-3 · Cited by 359
Fast escape of hydrogen from gas cavities around corroding magnesium implants
Kuhlmann, J., Bartsch, I., Willbold, E., Schuchardt, S., Holz, O., Hort, N., Höche, D., Heineman, W. R., & Witte, F. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.10.008 · Cited by 310
Mei, D., Lamaka, S. V., Lu, X., & Zheludkevich, M. L. (2020) · Corrosion Science · doi:10.1016/j.corsci.2020.108722 · Cited by 284
Fournier, V., Marcus, P., & Olefjord, I. (2002) · Surface and Interface Analysis · doi:10.1002/sia.1346 · Cited by 278
Comparative in vitro Study on Pure Metals (Fe, Mn, Mg, Zn and W) as Biodegradable Metals
Cheng, J., Liu, B., Wu, Y. H., & Zheng, Y. F. (2013) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2013.03.019 · Cited by 249
Mineralization of hydroxyapatite in electrospun nanofibrous poly(L‐lactic acid) scaffolds
Chen, J., Chu, B., & Hsiao, B. S. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30799 · Cited by 239
Iron and iron-based alloys for temporary cardiovascular applications
Francis, A. A., Yang, Y., Virtanen, S., & Boccaccini, A. R. (2015) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-015-5473-8 · Cited by 218
Self-citationJamesh, M. I., Wu, G., Zhao, Y., McKenzie, D. R., Bilek, M. M. M., & Chu, P. K. (2015) · Corrosion Science · doi:10.1016/j.corsci.2014.11.015 · Cited by 193
Chen, Y., Zhang, W., Maitz, M. F., Chen, M., Zhang, H., Mao, J., Zhao, Y., Huang, N., & Wan, G. (2016) · Corrosion Science · doi:10.1016/j.corsci.2016.05.039 · Cited by 172
Mei, D., Lamaka, S. V., González, J., Feyerabend, F., Willumeit‐Römer, R., & Zheludkevich, M. L. (2018) · Corrosion Science · doi:10.1016/j.corsci.2018.11.011 · Cited by 165
Protein adsorption on magnesium and its alloys: A review
Höhn, S., Virtanen, S., & Boccaccini, A. R. (2018) · Applied Surface Science · doi:10.1016/j.apsusc.2018.08.173 · Cited by 156
Self-citationThe uptake of titanium ions by hydroxyapatite particles—structural changes and possible mechanisms
Ribeiro, C. C., Gibson, I. R., & Barbosa, M. A. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.09.043 · Cited by 150
Gu, X., Zheng, Y., & Chen, L. (2009) · Biomedical Materials · doi:10.1088/1748-6041/4/6/065011 · Cited by 119
Mei, D., Lamaka, S. V., Feiler, C., & Zheludkevich, M. L. (2019) · Corrosion Science · doi:10.1016/j.corsci.2019.03.039 · Cited by 112
An in vivo study on the metabolism and osteogenic activity of bioabsorbable Mg–1Sr alloy
Tie, D., Guan, R., Liu, H. H., Cipriano, A. F., Liu, Y., Wang, Q., Huang, Y., & Hort, N. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.11.014 · Cited by 105
Liu, X., Yang, H., Xiong, P., Li, W., Huang, H., & Zheng, Y. (2019) · Corrosion Science · doi:10.1016/j.corsci.2019.05.018 · Cited by 101
Comparative Studies on Degradation Behavior of Pure Zinc in Various Simulated Body Fluids
Liu, X., Yang, H., Liu, Y., Xiong, P., Guo, H., Huang, H., & Zheng, Y. (2019) · JOM · doi:10.1007/s11837-019-03357-3 · Cited by 96
Local pH and Its Evolution Near Mg Alloy Surfaces Exposed to Simulated Body Fluids
Lamaka, S. V., Gonzalez, J., Mei, D., Feyerabend, F., Willumeit‐Römer, R., & Zheludkevich, M. L. (2018) · Advanced Materials Interfaces · doi:10.1002/admi.201800169 · Cited by 95
Accelerated Degradation Behavior and Cytocompatibility of Pure Iron Treated with Sandblasting
Zhou, J., Yang, Y., Frank, M. A., Detsch, R., Boccaccini, A. R., & Virtanen, S. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b07068 · Cited by 75
Self-citationProtective layer formation on magnesium in cell culture medium
Wagener, V., & Virtanen, S. (2016) · Materials Science and Engineering C · doi:10.1016/j.msec.2016.03.003 · Cited by 71
Self-citationCui, L., Hu, Y., Zeng, R., Yang, Y.-X., Sun, D.-D., Li, S., Zhang, F., & Han, E. (2017) · Journal of Material Science and Technology · doi:10.1016/j.jmst.2017.01.005 · Cited by 67
Zhou, J., Frank, M. A., Yang, Y., Boccaccini, A. R., & Virtanen, S. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.08.066 · Cited by 54
Self-citationDong, H., Zhou, J., & Virtanen, S. (2019) · Applied Surface Science · doi:10.1016/j.apsusc.2019.07.165 · Cited by 49
Self-citationMagnesium-Based Bioresorbable Stent Materials: Review of Reviews
Aljihmani, L., Alić, L., Boudjemline, Y., Hijazi, Z. M., Mansoor, B., Serpedin, E., & Qaraqe, K. A. (2019) · Journal of Bio- and Tribo-Corrosion · doi:10.1007/s40735-019-0216-x · Cited by 46
Metadata
- Authors
- Dong, H., Lin, F., Boccaccini, A. R., & Virtanen, S.
- Venue
- Corrosion Science
- Publisher
- Elsevier BV
- Published
- 2021-04
- Volume
- 182
- Pages
- 109278
- ISSN
- 0010-938X (ISSN-L)
- OpenAlex
- W3125554095
- Cited by
- 160
- References
- 37
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.