Cited by 242Smart Grid Security and ResilienceIndustrial Automation and Control SystemsInformation and Cyber Security

SCADA (supervisory control and data acquisition) systems: Vulnerability assessment and security recommendations

Upadhyay, Darshana, Sampalli, Srinivas·2020·Computers & Security

Abstract

Abstract Growing dependency and remote accessibility of automated industrial automation systems have transformed SCADA (Supervisory Control and Data Acquisition) networks from strictly isolated to highly interconnected networks. This increase in interconnectivity between systems raises operational efficiency due to the ease of controlling and monitoring of processes, however, this inevitable transformation also exposes the control system to the outside world. As a result, effective security strategies are required as any vulnerability of the SCADA system could generate severe financial and/or safety implications. The primary task when identifying holes in the system is to have proper awareness of the SCADA vulnerabilities and threats. This approach will help to identify potential breaches or aspects in the system where a breach may occur. This paper describes various types of potential SCADA vulnerabilities by taking real incidents reported in standard vulnerability databases. A comprehensive review of each type of vulnerability has been discussed along with recommendations for the improvement of SCADA security systems.

Integrity signals

Registry

Crossref · 10.1016/j.cose.2019.101666

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The exploitation of field device firmware is a least focused research area.

    “Surprisingly, the exploitation of field device firmware is a least focused research area [59,60,61].”

    From Architecture and security of SCADA systems: A review (2021) · cites this paper as [59]

Cites

1 retracted

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Upadhyay, D., & Sampalli, S.
Affiliations
Dalhousie University (CA)
Corresponding author
Sampalli, Srinivas
Venue
Computers & Security
Publisher
Elsevier BV
Published
2020-02
Volume
89
Pages
101666
ISSN
0167-4048 (ISSN-L)
OpenAlex
W2987085812
Cited by
242
References
31
Citations by year
2026: 18 · 2025: 43 · 2024: 50 · 2023: 41 · 2022: 34 · 2021: 35 · 2020: 21
FWCI
12.46
Type
journal article
Language
en
Open access
closed
Locations
Computers & Security (publishedVersion)
Funders
Natural Sciences and Engineering Research Council of Canada
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Smart Grid Security and Resilience
  • Physical Sciences › Engineering › Control and Systems Engineering › Industrial Automation and Control Systems
  • Physical Sciences › Computer Science › Information Systems › Information and Cyber Security
Keywords
SCADA, supervisory control and data acquisition, industrial control systems, vulnerability assessment, security recommendations, cyber threats, vulnerability databases, industrial automation security, network interconnectivity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.