Aim of this review was to describe the main technologies for non-invasive glucose monitoring and the corresponding most relevant devices. The review tries to overcome the limitations of previous reviews on this topic, such as the lack of objective criteria for inclusion or exclusion of technologies or devices, and the poor organization of the information, which often does not allow easy comparison between technologies and devices. In this review, the information is concise and organized into specific categories, and hence it becomes easy to compare advantages and disadvantages of the different technologies and devices. For technologies, the categories of information considered are the technology name, the underlying physical principle, the technology limitations and the measurement sites on the human body. For devices, the categories of information are the device name, its approval condition (FDA Approval and/or CE Mark), the technology on which it is based, a device general description, the tests performed on the device, the corresponding results, safety information, aspects affecting usability, current status of the device and the manufacturer, an Internet reference for the device. A total of 14 technologies and 16 devices are included. Conclusions of the review were that, despite some interesting and promising technologies and devices, a satisfactory solution to the non-invasive glucose monitoring problem still requires further efforts.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Optical detection of glucose via near infrared (NIR) spectroscopy enables 90–95% of the light to pass through the human stratum corneum and epidermis into subcutaneous space with minimal tissue adsorption independent of skin pigmentation.19,40–41”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [41]
Citations
Cites
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Prospects forin vivoRaman spectroscopy
Hanlon, E. B., Manoharan, R., Koo, T.-W., Shafer‐Peltier, K., Motz, J. T., Fitzmaurice, M., Kramer, J. R., Itzkan, I., Dasari, R. R., & Feld, M. S. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/201 · Cited by 906
Diabetes Control and Complications Trial
Yue, D. K., Colagiuri, S., McElduff, A., & Silink, M. (1993) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1993.tb141357.x · Cited by 575
Hyponatremia: evaluating the correction factor for hyperglycemia
Hillier, T. A., Abbott, R. D., & Barrett, E. J. (1999) · The American Journal of Medicine · doi:10.1016/s0002-9343(99)00055-8 · Cited by 567
Monnier, V. M., Bautista, O., Kenny, D., Sell, D. R., Fogarty, J., Dahms, W., Cleary, P. A., Lachin, J., & Genuth, S. (1999) · Diabetes · doi:10.2337/diabetes.48.4.870 · Cited by 469
Combined In Vivo Confocal Raman Spectroscopy and Confocal Microscopy of Human Skin
Caspers, P. J., Lucassen, G. W., & Puppels, G. J. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74501-9 · Cited by 453
Tierney, M. J., Tamada, J. A., Potts, R. O., Jovanovic, L., & Garg, S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00189-0 · Cited by 390
Yonzon, C. R., Haynes, C. L., Zhang, X., Walsh, & Van Duyne, R. P. (2004) · Analytical Chemistry · doi:10.1021/ac035134k · Cited by 376
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Khalil, O. S. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.2.165 · Cited by 331
Noninvasive Blood Glucose Monitoring With Optical Coherence Tomography
Larin, K. V., Eledrisi, M. S., Motamedi, M., & Esenaliev, R. O. (2002) · Diabetes Care · doi:10.2337/diacare.25.12.2263 · Cited by 300
Flagged first, then by citations
Research works printed but not linked: 2
- R.W. Waynant, V.M. Chenault, Overview of non-invasive fluid glucose measurement using optical techniques to maintain glucose control in diabetes mellitus (http://www.ieee.org/organizations/pubs/newsletters/leos/apr98/overview.htm. Last checked 22/03/2006).
- R.J. McNichols, B.D. Cameron, G.L. Coté, Development of a non-invasive polarimetric glucose sensor (http://www.ieee.org/organizations/pubs/newsletters/leos/apr98/glucosesensor.htm. Last checked 22/03/2006).
Cited by
Sorted by citations
Items 201–283 of 283
Glucometry and Pulse Oximetry - Comparative Noninvasive Methods for Determining Blood Glucose
Marius, I. (2019) · E-Health and Bioengineering Conference (EHB) · doi:10.1109/ehb47216.2019.8970001 · Cited by 2
A flexible GOx/PB/Au film biosensor for the detection of glucose
Cai, K., Bao, Y., Liu, Y., & Li, B. (2024) · Electroanalysis · doi:10.1002/elan.202400092 · Cited by 2
Noninvasive in Vivo Evaluation of Mouse-Blood Glycemia with a Microwave Spiral Sensor
Babajanyan, A., Minasyan, B., Odabashyan, L., Kim, S., Kim, J., Lee, J.-H., Friedman, B., & Lee, K. (2021) · Journal of Contemporary Physics (Armenian Academy of Sciences) · doi:10.3103/s1068337221010060 · Cited by 2
Glucose concentration monitoring using a small Fabry-Pérot etalon
Martini, J., Kiesel, P., Roe, J. N., & Bruce, R. H. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3153848 · Cited by 2
Portable non-invasive blood glucose apparatus based on DSP
Zhu, J., Chen, Z., Xing-liang, J., & Wang, D. (2009) · JOURNAL OF ELECTRONIC MEASUREMENT AND INSTRUMENT · doi:10.3724/sp.j.1187.2009.06108 · Cited by 2
Stepanenko, O. V., Stepanenko, O. V., Fonin, A. V., Verkhusha, V. V., Kuznetsova, I. М., & Константинович, Т. К. (2012) · Journal of Spectroscopy · doi:10.1155/2012/169579 · Cited by 2
Chowdhury, K., Srivastava, A., Sharma, N., & Sharma, S. (2014) · Cited by 2
Yusof, Z. M., Aziz, N. A. M., Hisham, M. H., Laili, M. H., Yatim, N. N. M., & Witjaksono, G. (2012) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2012.6498177 · Cited by 2
Serum and salivary glucose levels in diabetes mellitus: A review
Nayyar, A., Kartheeki, B., Ravikiran, A., Samatha, Y., Priyanka, K., & Pranusha, D. (2017) · Nigerian Journal of General Practice · doi:10.4103/njgp.njgp_15_17 · Cited by 2
Teutsch, T., Mesch, M., Giessen, H. W., & Tarín, C. (2017) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2017.08.913 · Cited by 2
Development of Integrated Health Care App for Non - Invasive Bio - Medical Application
Prasad, B. K. S., Sunil, D., Gowda, A., Kotraswamy, & Vijay (2019) · IEEE International Conference on Distributed Computing, VLSI, Electrical Circuits and Robotics (DISCOVER) · doi:10.1109/discover47552.2019.9007969 · Cited by 2
A Non-Invasive IoT-Based Glucose Level Monitoring System
Jain, S., Paul, S., Majhi, B., Pegu, K., & Majhi, V. (2022) · Current Signal Transduction Therapy · doi:10.2174/1574362417666220524085231 · Cited by 2
Multisensor noninvasive blood glucose monitoring system
Samadarsinee, S. (2015) · Holmes Museum Of Anthropology (Wichita State University) · Cited by 2
Maulida, P. Y. D., Maharani, A. I., Basyari, A. A., & Nasori, N. (2023) · AIP conference proceedings · doi:10.1063/5.0115595 · Cited by 1
(2023) · International Journal of Nanotechnology and Nanomedicine · doi:10.33140/ijnn.08.01.09 · Cited by 1
High precision blood glucose measurement from breath analysis
Chundru, G., Pillagolla, D. P. R., Danduboyina, S. K., Anne, G. C., & Myla, S. Y. (2025) · AIP conference proceedings · doi:10.1063/5.0248748 · Cited by 1
Chowdhury, M. K., Srivastava, A., Sharma, N., & Sharma, S. (2014) · Biosciences Biotechnology Research Asia · doi:10.13005/bbra/1563 · Cited by 1
Portable device for automatic control of hemodynamic and biochemical blood parameters
Elbaeva, A. D., Elbaeva, R. I., & Senov, K. M. (2016) · International Conference "Quality Management, Transport and Information Security, Information Technologies" (IT&QM&IS) · doi:10.1109/itmqis.2016.7751898 · Cited by 1
Camou, S. (2012) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-642-32538-0_5 · Cited by 1
A Critical Review on Current Devloping Non-Invasive Glucose Monitoring Technologies and Devices
Patel, A. I., Rachhadiya, J., Vadariya, P., Vysh, A. J., & Patel, A. B. (2022) · Asian Journal of Pharmaceutical Analysis · doi:10.52711/2231-5675.2022.00044 · Cited by 1
Hung, S. C., Chen, C.-C., Lin, Y.-C., Lin, C., Chen, W.-L., Chien, W.-H., & Huang, J.-S. (2023) · Biomedical Imaging and Sensing Conference (BISC) · doi:10.1117/12.3005584 · Cited by 1
Sun, X., & Xiao, F. (2024) · Journal of Food Measurement & Characterization · doi:10.1007/s11694-024-02892-1 · Cited by 1
Domnin, K. G., Cherevatenko, G., & Aksenov, E. T. (2014) · Journal of Physics Conference Series · doi:10.1088/1742-6596/541/1/012041 · Cited by 1
A Simple Photometer as a Helping Device in Measuring Blood Glucose
Tedjo, A., Prafiantini, E., Suprapto, A. P., Ibrahim, A. S., Riyanto, S. A., & Priyanto, D. (2014) · Makara Journal of Health Research · doi:10.7454/msk.v18i2.4071 · Cited by 1
Optimal Driving Current for Improved Noninvasive Near Infrared Glucose Meter
Omar, M., Ahmad, M. Y., & Zaman, W. S. W. K. (2021) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-030-65092-6_19 · Cited by 1
Development of electrochemical sensors for hydrogen peroxide determination
Borràs‐Brull, M. (2020) · Dialnet (Universidad de la Rioja) · Cited by 1
A 1mW Time Constant Based Impedance Spectroscopy for Non-Invasive Blood Glucose Monitoring
Hina, A., & Saadeh, W. (2021) · International Conference on Microwave, Antennas & Circuits (ICMAC) · doi:10.1109/icmac54080.2021.9678285 · Cited by 1
Wang, H., & Wu, B. (2008) · Springer eBooks · doi:10.1007/978-3-540-79039-6_75 · Cited by 1
Non‐invasive Glucose Biosensors Based on Nanomaterials
Faridbod, F., Ganjali, M. R., Larijani, B. A., & Norouzil, P. (2015) · Wiley eBooks · doi:10.1002/9781118998922.ch10 · Cited by 1
Dual Wavelength Polarimetry for Glucose Sensing in the Anterior Chamber of the Eye
Malik, B. H. (2012) · OakTrust (Texas A&M University Libraries) · Cited by 1
de Leon, L. S., & Eduardo, N. (2010) · Cited by 1
Sacks, D. B., Arnold, M. A., Metzger, B. E., & Nathan, D. M. (2012) · Cited by 1
He-Ne Laser Imaging Probes Premature Diabetes Mellitus
Singh, A. K. (2015) · International Journal of Biomedical Materials Research · doi:10.11648/j.ijbmr.20150302.11
Rajan, S. A. P., & Towe, B. C. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944509
Compact optical system for imaging type two-dimensional spectroscopic tomography
Abeygunawardhana, P. K. W., Nakada, S., Suzuki, S., Nishiyama, A., & Ishimaru, I. (2013) · IEEE International Conference on Industrial and Information Systems (ICIIS) · doi:10.1109/iciinfs.2013.6732030
Sanki, P. K. (2015) · International Conference on Signal Processing and Integrated Networks (SPIN) · doi:10.1109/spin.2015.7095405
Michelson Interferometer for near Infrared Wavelengths
Mendoza-Figueroa, V., & de la Cruz-Alejo, J. (2013) · Advanced materials research · doi:10.4028/www.scientific.net/amr.677.79
The Future of Diabetes Therapy
McMahon, G. T. (2009) · Springer eBooks · doi:10.1007/978-0-387-09841-8_48
Christopher, C., Heath, D., & Connolly, P. (2011) · InTech eBooks · doi:10.5772/19340
Srivastava, A., Chowdhury, K., Sharma, S., & Sharma, N. (2014)
Characterization of Physiological
Hossain, Q. D., & Dhar, S. K. (2013)
The V iability of Intralipid optical Phantom for Developing Noninvasive Blood G lucometer
Srivastava, A., Chowdhury, K., Sharma, S., & Sharma, N. (2014)
Ophthalmic Glucose Monitoring System: A Novel Diagnostic Approach for Diabetes
Jani, P., Patel, G., Patel, K., Patel, S. H., Jain, H., & Pradhan, P. (2014)
VOLUME VARIATION COMPENSATION IN NON-INVASIVE ELECTROMAGNETIC BLOOD GLUCOSE MEASUREMENT
Alavi, S. M., Jafari, R., & Granpayeh, N. (2011) · ADST Journal
SRIVASTAVA, A., Chowdhury, M. K., Sharma, S., & Sharma, N. (2014) · Biomedical & Pharmacology Journal · doi:10.13005/bpj/547
Signal conditioning for imaging type Fourier spectroscopy using Independent Component Analysis
Abeygunawardhana, P. K. W., Fujiwara, M., Suzuki, S., & Ishimaru, I. (2014) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2014.6981649
Romero, J. A., Vargas, J. E., Fonthal, F., & Cabrera, J. J. (2015) · Redalyc (Universidad Autónoma del Estado de México)
Sbrignadello, S., Pacini, G., & Tura, A. (2016) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-32703-7_146
Self-citationTransmittance and reflectance measurements of anhydrous glucose concentrations on solutions
González-Viveros, N., Cerecedo-Núñez, H. H., Garcı́a-Guzmàn, J., & Padilla-Sosa, P. (2016) · OSA Advanced Photonics Congress · doi:10.1364/sensors.2016.sew2f.7
Precision Controlled Variable Phase Filter for Imaging Type Two-Dimensional Spectroscopic Tomography
Abeygunawardhana, P. K. W., Suzuki, S., Ishimaru, I., & Nishiyama, A. (2013) · International Conference on Social Computing · doi:10.1109/socialcom.2013.129
Analysis of anhydrous glucose and human serum assisted by Raman spectroscopy
González-Viveros, N., Cerecedo-Núñez, H. H., Padilla-Sosa, P., Flores-Gil, A., May, M., Basurto‐Pensado, M. A., Alcántara, G., & Muñiz, O. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2249876
Breath Signal Analysis for Diabetics
Zhang, D. D., Guo, D., & Yan, K. (2017) · Springer eBooks · doi:10.1007/978-981-10-4322-2_13
Sbrignadello, S., Tura, A., & Ravazzani, P. (2013) · Research & Reviews in Electrochemistry
Self-citationDeveloping of biochemical express analyzers of blood based on computer simulation
Elbaeva, A. D., Elbaeva, R. I., Senov, K. M., & Elbaev, A. D. (2017) · International Conference "Quality Management, Transport and Information Security, Information Technologies" (IT&QM&IS) · doi:10.1109/itmqis.2017.8085837
Research Based on Non-Invasive Blood Glucose Monitoring Equipment
Zhao, M., Du, Y., Jia, Y., & Liu, C. (2018) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1069/1/012012
calibration modeling in non invasive blood glucose levels using support vector regression
Rosni, A., Wijayanto, H., & Erfiani, A. (2018) · International Journal of Scientific Research in Science Engineering and Technology · doi:10.32628/ijsrset21841123
Non-invasive Blood Glucose Estimation Methodology Using Predictive Glucose Homeostasis Models
Panwar, M., Acharyya, A., & Shafik, R. (2018) · International Symposium on Embedded Computing and System Design (ISED) · doi:10.1109/ised.2018.8703991
Perspectives on Non-Invasive Glucose Sensing using Flexible Hybrid-Printed Electronics Systems
Bassant, H., Refaei, A., Fayomi, C. J. B., & Boukadoum, M. (2019) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2019.8702818
Modern transdermal terapötik sistemlerin tedavideki yeri
YAPAR, İ. Ö. A. (2008) · Ankara Universitesi Eczacilik Fakultesi Dergisi · doi:10.1501/eczfak_0000000497
Design of Automatic Insulin Dosage Indicator for Diabetic Patients Using BMI
Kanimozhi, R., & Saravanakumar, S. (2020) · INTERNATIONAL JOURNAL OF ADVANCED INFORMATION AND COMMUNICATION TECHNOLOGY · doi:10.46532/ijaict-2020017
Assessment of Various Physiological Fluids in Diabetes Diagnosis-A Mini Review
Anuradha, G. (2020) · Modern Research in Dentistry · doi:10.31031/mrd.2020.05.000613
Recognition of Signs of Diabetes in Electric Cardiac Signals by Neural Network Analysis
Isakov, R. V., & Ananeva, A. (2021) · Biomedical Engineering · doi:10.1007/s10527-021-10074-2
Non-invasive microwave detection of blood glucose level
Oloyo, A. (2020) · Research Explorer (The University of Manchester)
Non Invasive Blood Glucose Measurement Technique for Diabetic Patients
Dharshini, S. P., Revathy, M., Soundharya, A., & Devi, R. M. (2020) · International Journal of Engineering and Advanced Technology · doi:10.35940/ijeat.c5591.029320
Glucometry and Pulse Oximetry - Comparative Noninvasive Methods for Determining Blood Glucose
Marius, I. (2021) · SCIREA Journal of Information Science and Systems Science · doi:10.54647/isss12058
IoT Based Electronic Valve System with Quantitative Control and Patient Monitoring
Nandan, R. (2022) · International Journal for Research in Applied Science and Engineering Technology · doi:10.22214/ijraset.2022.40131
McNichols, R. J. (2014) · CRC Press eBooks · doi:10.1201/b17289-4
Current literature in diabetes
(2007) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.812
Near-Infrared Spectroscopy for Noninvasive Glucose Detection in Aqueous SolutionPreprint
Attia, H., Mahnashi, Y., Qaid, A., Mohamed, N. E., & Qureshi, K. K. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4510265
The Clinical Accuracy of Non-Invasive Glucose Monitoring for ex vivo Artificial Pancreas
Levy, M. M., & Levy, Y. M. (2016) · Journal of Emerging Investigators · doi:10.59720/16-008
Microstrip Sensors for Biomedical Engineering
Elsheakh, D. N., & Eldamak, A. R. A. M. A. (2024) · Springer eBooks · doi:10.1007/978-3-031-39824-7_18
Jeong, J., Lim, S.-K., Choi, K. S., & Kim, H.-P. (2024) · International Conference on Biomedical Engineering and Applications (ICBEA) · doi:10.1109/icbea62825.2024.00034
Biosensors and noninvasive diagnostics
Karyakin, A. A. (2025) · Priroda · doi:10.7868/s0032874x25010049
zaman, M.-U., Promy, Z. T., & Biswas, N. K. (2025) · doi:10.38124/ijisrt/25may069
Overview of Non-Invasive Blood Glucose Monitoring Techniques: Focus on Optical Methods
Fdil, K., Elhir, S., Debbarh, I., & Medromi, H. (2025) · E3S Web of Conferences · doi:10.1051/e3sconf/202563102007
Mukhtar, H., Zaelani, M. M., Nasrullah, M. R., & Susanti, H. (2025) · Engineering Science Letter · doi:10.56741/iistr.esl.001218 · Cited by 2
Choi, H., Jin, M., & Yoo, W. S. (2025) · Medical Lasers · doi:10.25289/ml.25.024
Innovative temperature-based non-invasive blood glucose monitoring using machine learning
Dirisala, H., Durgaprasadarao, P., Marthala, K., Dandu, T., & Chirumamilla, S. K. (2026) · AIP conference proceedings · doi:10.1063/5.0322649
Buisson, C. (2023) · theses.fr (ABES) · doi:10.70675/85221ac5z6bbcz4138z8daczcb1076a199c8
A novel prototype for pain-free blood glucose monitoring: impedance and NIR-based approach
Gnaś, D., Oleszek, M., & Wójcik, D. P. (2026) · PRZEGLĄD ELEKTROTECHNICZNY · doi:10.15199/48.2026.04.13
Experimental analysis of optical wavelength for noninvasive measurement of glucose
Zalke, J. B., Narkhede, N. P., Pandey, S. R., Waghmare, N. R., Bhute, R., & Bandali, H. N. (2026) · AIP conference proceedings · doi:10.1063/5.0328761
Gnaś, D., Kulisz, M., Kłosowski, G., Rymarczyk, T., Wójcik, D. P., & Olszewski, P. (2026) · ACM Annual International Conference on Mobile Computing and Networking (MobiCom) · doi:10.1145/3795866.3844748
Metadata
- Authors
- Tura, A., Maran, A., & Pacini, G.
- Affiliations
- National Research Council (IT)
- University of Padua (IT)
- Corresponding author
- Tura, Andrea
- Venue
- Diabetes Research and Clinical Practice
- Publisher
- Elsevier BV
- Published
- 2007-07
- Volume
- 77
- Issue
- 1
- Pages
- 16-40
- ISSN
- 0168-8227 (ISSN-L)
- OpenAlex
- W2139729200
- Cited by
- 283
- References
- 70
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 11 · 2023: 11 · 2022: 12 · 2021: 14 · 2020: 19 · 2019: 16 · 2018: 21 · 2017: 24 · 2016: 16 · 2015: 22 · 2014: 26 · 2013: 17 · 2012: 22
- FWCI
- 0.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Diabetes Research and Clinical Practice (publishedVersion)
- PubMed (publishedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Keywords
- non-invasive glucose monitoring, blood glucose measurement, diabetes mellitus, glucose monitoring devices, FDA approval, CE marking, device safety, usability, measurement site
- MeSH terms
- Adult, Blood Glucose, Child, Endocrinology, Humans, Iontophoresis, Patient Compliance, Spectrum Analysis, Spectrum Analysis, Raman, Ultrasonics, Blood Glucose Self-Monitoring, Electric Impedance, Device Approval, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review