Abstract

BACKGROUND: Skin cancer (SC), especially melanoma, is a growing public health burden. Experimental studies have indicated a potential diagnostic role for deep learning (DL) algorithms in identifying SC at varying sensitivities. Previously, it was demonstrated that diagnostics by dermoscopy are improved by applying an additional sonification (data to sound waves conversion) layer on DL algorithms. The aim of the study was to determine the impact of image quality on accuracy of diagnosis by sonification employing a rudimentary skin magnifier with polarized light (SMP). METHODS: Dermoscopy images acquired by SMP were processed by a first deep learning algorithm and sonified. Audio output was further analyzed by a different secondary DL. Study criteria outcomes of SMP were specificity and sensitivity, which were further processed by a F2-score, i.e. applying a twice extra weight to sensitivity over positive predictive values. FINDINGS: Patients (n = 73) fulfilling inclusion criteria were referred to biopsy. SMP analysis metrics resulted in a receiver operator characteristic curve AUC's of 0.814 (95% CI, 0.798-0.831). SMP achieved a F2-score sensitivity of 91.7%, specificity of 41.8% and positive predictive value of 57.3%. Diagnosing the same set of patients' lesions by an advanced dermoscope resulted in a F2-score sensitivity of 89.5%, specificity of 57.8% and a positive predictive value of 59.9% (P=NS). INTERPRETATION: DL processing of dermoscopic images followed by sonification results in an accurate diagnostic output for SMP, implying that the quality of the dermoscope is not the major factor influencing DL diagnosis of skin cancer. Present system might assist all healthcare providers as a feasible computer-assisted detection system. FUND: Bostel Technologies. Trial Registration clinicaltrials.gov Identifier: NCT03362138.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ebiom.2019.04.055

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 126

Metadata

Authors
Dascalu, A., & David, E. O.
Venue
EBioMedicine
Publisher
Elsevier BV
Published
2019-05
Volume
43
Pages
107-113
ISSN
2352-3964 (ISSN-L)
OpenAlex
W2946796433
Cited by
126
References
4
FWCI
6.35
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Skin cancer detection by deep learning and sound analysis algorithms: A prospective clinical study of an elementary dermoscope. https://app.cochat.ai/papers/10.1016/j.ebiom.2019.04.055
The paper
Dascalu, A., & David, E. O. (2019). Skin cancer detection by deep learning and sound analysis algorithms: A prospective clinical study of an elementary dermoscope. EBioMedicine. https://doi.org/10.1016/j.ebiom.2019.04.055

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.