Cited by 18Non-Invasive Vital Sign MonitoringMosquito-borne diseases and controlArtificial Intelligence in Healthcare

Towards a machine-learning assisted non-invasive classification of dengue severity using wearable PPG data: a prospective clinical study

Open access
Karolcik, Stefan, Manginas, Vasileos, Chanh, Ho Quang, Daniels, John, Giang, Nguyen Thi, Huyen, Vu Ngo Thanh, Hoang, Minh Tu Van, Phan Nguyen Quoc, Khanh +11 more·2024·eBioMedicine

Abstract

BACKGROUND: Dengue epidemics impose considerable strain on healthcare resources. Real-time continuous and non-invasive monitoring of patients admitted to the hospital could lead to improved care and outcomes. We evaluated the performance of a commercially available wearable (SmartCare) utilising photoplethysmography (PPG) to stratify clinical risk for a cohort of hospitalised patients with dengue in Vietnam. METHODS: We performed a prospective observational study for adult and paediatric patients with a clinical diagnosis of dengue at the Hospital for Tropical Disease, Ho Chi Minh City, Vietnam. Patients underwent PPG monitoring early during admission alongside standard clinical care. PPG waveforms were analysed using machine learning models. Adult patients were classified between 3 severity classes: i) uncomplicated (ward-based), ii) moderate-severe (emergency department-based), and iii) severe (ICU-based). Data from paediatric patients were split into 2 classes: i) severe (during ICU stay) and ii) follow-up (14-21 days after the illness onset). Model performances were evaluated using standard classification metrics and 5-fold stratified cross-validation. FINDINGS: We included PPG and clinical data from 132 adults and 15 paediatric patients with a median age of 28 (IQR, 21-35) and 12 (IQR, 9-13) years respectively. 1781 h of PPG data were available for analysis. The best performing convolutional neural network models (CNN) achieved a precision of 0.785 and recall of 0.771 in classifying adult patients according to severity class and a precision of 0.891 and recall of 0.891 in classifying between disease and post-disease state in paediatric patients. INTERPRETATION: We demonstrate that the use of a low-cost wearable provided clinically actionable data to differentiate between patients with dengue of varying severity. Continuous monitoring and connectivity to early warning systems could significantly benefit clinical care in dengue, particularly within an endemic setting. Work is currently underway to implement these models for dynamic risk predictions and assist in individualised patient care. FUNDING: EPSRC Centre for Doctoral Training in High-Performance Embedded and Distributed Systems (HiPEDS) (Grant: EP/L016796/1) and the Wellcome Trust (Grants: 215010/Z/18/Z and 215688/Z/19/Z).

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ebiom.2024.105164

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

1 of the 23 references couldn’t be matched to a known paper.

Research works printed but not linked: 2

  1. [3]Organization W.H. Dengue guidelines for diagnosis, treatment, prevention and control new edition 2009 World Health Organization 23762963
  2. [6]Janak J. Howard J. Goei K. Predictors of the onset of Hemodynamic decompensation during progressive central hypovolemia: comparison of the peripheral perfusion index, pulse pressure variability, and compensatory reserve index Shock 11 2015 44 26529655

Cited by

Sorted by citations

Authors
Karolcik, S., Manginas, V., Chanh, H. Q., Daniels, J., Giang, N. T., Huyen, V. N. T., Hoang, M. T. V., Phan Nguyen Quoc, K., Hernandez, B., Ming, D. K., Nguyen Van, H., Phan, T. Q., Trieu, H. T., Luong Thi Hue, T., Holmes, A. H., Thwaites, L., Phan Vinh, T., Yacoub, S., & Georgiou, P.
Affiliations
  • Imperial College London (GB)
  • Oxford University Clinical Research Unit (VN)
Corresponding author
Karolcik, Stefan
Venue
eBioMedicine
Publisher
Elsevier BV
Published
2024-06
Volume
104
Pages
105164
ISSN
2352-3964 (ISSN-L)
OpenAlex
W4399129797
Cited by
18
References
23
Citations by year
2026: 9 · 2025: 8 · 2024: 1
FWCI
1.97
Type
journal article
Language
en
Open access
Locations
  • EBioMedicine (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Wellcome Trust
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Mosquito-borne diseases and control
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
Keywords
dengue, disease severity classification, continuous physiological monitoring, convolutional neural networks, pediatric dengue, hospitalized patients, clinical risk stratification, early warning systems, non-invasive monitoring, low-cost wearable device
MeSH terms
Machine Learning, Wearable Electronic Devices, Adolescent, Adult, Child, Dengue, Female, Humans, Male, Prospective Studies, Severity of Illness Index, Vietnam, Photoplethysmography, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review