Pulmonary Artery Acceleration Time Provides a Reliable Estimate of Invasive Pulmonary Hemodynamics in Children
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Background Pulmonary artery acceleration time (PAAT) is a non-invasive method to assess pulmonary hemodynamics, but lacks validity in children. This study sought to evaluate the accuracy of Doppler echocardiography (DE) derived PAAT in predicting right heart catheterization (RHC) derived pulmonary arterial pressure (PAP), pulmonary vascular resistance (PVR) and compliance in children. Methods Prospectively acquired and retrospectively measured DE derived PAAT and RHC derived systolic PAP (sPAP), mean PAP (mPAP), index PVR (PVRi) and compliance were compared by regression analysis in a derivation cohort of 75 children (median age, 5.3 years; 1.3–12.6) with wide ranges of pulmonary hemodynamics. To account for heart rate variability, PAAT was adjusted for right ventricle ejection time (RVET) and corrected by the RR interval. Regression equations incorporating PAAT and PAAT:RVET from the derivation cohort were then evaluated for the accuracy of its predictive values for invasive pulmonary hemodynamics in a validation cohort of 50 age- and weight- matched children with elevated PAP and PVR. Results There were significant inverse correlations between PAAT and RHC derived mPAP (r = −0.82) and PVRi (r= −0.78) and direct correlation (r= 0.78) between PAAT and pulmonary compliance in the derivation cohort. For detection of pulmonary hypertension (PRVi > 3 WU x m2 and mPAP > 25 mmHg), PAAT < 90 msec and PAAT:RVET < 0.31 resulted in a sensitivity of 97% and a specificity of 95%. In the derivation cohort, the regression equations relating PAAT with mPAP and PVRi were: mPAP = 48 – 0.28 x PAAT and PVRi = 9 –0.07 x PAAT. These PAAT integrated equations predicted RHC measured pulmonary hemodynamics in the validation cohort with good correlations (r = 0.88, 0.83 respectively), small biases (<10%), and minimal coefficient of variation (<8%). Conclusions PAAT inversely correlates with RHC measured pulmonary hemodynamics and directly correlates with pulmonary arterial compliance in children. The study established PAAT based regression equations in children to accurately predict RHC derived PAP and PVR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.10.003 · Cited by 12,362
Updated clinical classification of pulmonary hypertension
Simonneau, G., Gatzoulis, M. A., Adatia, I., Celermajer, D., Denton, C., Ghofrani, A., Gomez Sanchez, M. A., Krishna Kumar, R., Landzberg, M., Machado, R. F., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.10.029 · Cited by 4,191 · cited 4×
“A receiver operating characteristic (ROC) curve was constructed to determine cutoff valueS for PAAT and PAAT/RVETwith the best sensitivity to predict pulmonary hypertension, defined as elevated PVR values (PVR > 2 WU and PVRi > 3 WU $ m(2)), elevated sPAP (>30 mm Hg), and mPAP > 25 mm Hg.(27) The statistical analysis…”
MethodInfluentialUpdated Clinical Classification of Pulmonary Hypertension
Simonneau, G., Robbins, I. M., Beghetti, M., Channick, R. N., Delcroix, M., Denton, C. P., Elliott, C. G., Gaine, S. P., Gladwin, M. T., Jing, Z.-C., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.04.012 · Cited by 2,093
Accuracy of Doppler Echocardiography in the Hemodynamic Assessment of Pulmonary Hypertension
Fisher, M. R., Forfia, P. R., Chamera, E., Housten-Harris, T., Champion, H. C., Girgis, R. E., Corretti, M. C., & Hassoun, P. M. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200811-1691oc · Cited by 1,075
Noninvasive evaluation of pulmonary hypertension by a pulsed Doppler technique.
Kitabatake, A., Inoue, M., Asao, M., Masuyama, T., Tanouchi, J., Morita, T., Mishima, M., Uematsu, M., Shimazu, T., Hori, M., et al. (1983) · Circulation · doi:10.1161/01.cir.68.2.302 · Cited by 779
A simple method for noninvasive estimation of pulmonary vascular resistance
Abbas, A. E., Fortuin, F. D., Schiller, N. B., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02973-x · Cited by 629
Champion, H. C., Michelakis, E. D., & Hassoun, P. M. (2009) · Circulation · doi:10.1161/circulationaha.106.674028 · Cited by 468 · cited 1×
“However, PVR alone does not represent the total afterload to the right ventricle, because it does not take into account the ‘‘impedance’’ to the forward pulsatile blood flow from backward pressure wave reflections from multiple bifurcations of the pulmonary circulation.(29) In pulmonary vascular disease, the noncompli…”
BackgroundComparison of three Doppler ultrasound methods in the prediction of pulmonary artery pressure
Chan, K.-L., Currie, P. J., Seward, J. B., Hagler, D. J., Mair, D. D., & Jamil Tajik, A. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80047-5 · Cited by 390 · cited 5×
“We plotted the R-R interval against PAAT/RVET.”
MethodInfluentialRich, J. D., Shah, S. J., Swamy, R. S., Kamp, A., & Rich, S. (2011) · Chest · doi:10.1378/chest.10-1269 · Cited by 368
Quantification of right ventricular afterload in patients with and without pulmonary hypertension
Lankhaar, J.-W., Westerhof, N., Faes, T. J. C., Marques, K. M. J., Marcus, J. T., Postmus, P. E., & Vonk-Noordegraaf, A. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00336.2006 · Cited by 338 · cited 1×
“This implies that RV afterload is a major contributor to the observed differences in RV function.(32) Intuitively, the development of significant decreased RV function might lead to a slower rise in ejection velocities early in systole and a longer PAAT.”
BackgroundArkles, J. S., Opotowsky, A. R., Ojeda, J., Rogers, F., Liu, T., Prassana, V., Marzec, L., Palevsky, H. I., Ferrari, V. A., & Forfia, P. R. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201004-0601oc · Cited by 246 · cited 1×
“Our study reveals that PAAT is a comprehensive quantitative index of pulmonary hemodynamics in children and represents the result of a dynamic interaction between RV mechanical performance and pulmonary vascular load and arterial compliance in children.(28) PAAT predictably shortens with increasing PVR, and the degree…”
BackgroundYared, K., Noseworthy, P., Weyman, A. E., McCabe, E., Picard, M. H., & Baggish, A. L. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.03.008 · Cited by 186 · cited 7×
“We plotted the R-R interval against PAAT/RVET.”
MethodInfluentialLevy, P. T., Sanchez Mejia, A. A., Machefsky, A., Fowler, S., Holland, M. R., & Singh, G. K. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.01.015 · Cited by 182 · cited 1×
“We assessed RV function using two-dimensional speckle-tracking echocardiography–derived global longitudinal systolic strain, a sensitive and reliable measure with published normative values in children.(26) One sonographer measured RV global longitudinal strain in the children who underwent simultaneous DE and RHC usi…”
MethodSelf-citationA Simple Echocardiographic Prediction Rule for Hemodynamics in Pulmonary Hypertension
Opotowsky, A. R., Ojeda, J., Rogers, F., Prasanna, V., Clair, M., Moko, L. E., Vaidya, A., Afilalo, J., & Forfia, P. R. (2012) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.112.976654 · Cited by 142 · cited 1×
“31 would identify most patients with mPAP > 25 mm Hg and PVRi > 3WU $m(2) in different clinical scenarios in children and is similar to published results in adults.(2,6,14,36) PAAT is not meant to replace invasive catheterization as the standard reference method, but it offers an effective screening tool for pediatric…”
ResultLevy, P. T., Holland, M. R., Sekarski, T. J., Hamvas, A., & Singh, G. K. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.06.005 · Cited by 90 · cited 3×
“8 were recognized as measures of minimal variability and positive reliability.(21)”
BackgroundMethodSelf-citationLanzarini, L. F., Fontana, A., Campana, C., & Klersy, C. (2005) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2004.03.026 · Cited by 74 · cited 1×
“31 would identify most patients with mPAP > 25 mm Hg and PVRi > 3WU $m(2) in different clinical scenarios in children and is similar to published results in adults.(2,6,14,36) PAAT is not meant to replace invasive catheterization as the standard reference method, but it offers an effective screening tool for pediatric…”
ResultGroh, G., Levy, P. T., Holland, M. R., Murphy, J. J., Sekarski, T. J., Myers, C., Hartman, D. P., Roiger, R. D., & Singh, G. K. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.09.016 · Cited by 58 · cited 9×
“(B) PA velocity curve with shortened PAAT in a patient with high PAP.”
BackgroundMethodResultSelf-citationCooper, M. J., Tyndall, M., & Silverman, N. H. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90421-4 · Cited by 30
Cited by
Echocardiographic Evaluation of Hemodynamics in Neonates and Children
Singh, Y. (2017) · Frontiers in Pediatrics · doi:10.3389/fped.2017.00201 · Cited by 116
Metadata
- Authors
- Levy, P. T., Patel, M. D., Groh, G., Choudhry, S., Murphy, J., Holland, M. R., Hamvas, A., Grady, M. R., & Singh, G. K.
- Venue
- Journal of the American Society of Echocardiography
- Publisher
- Elsevier BV
- Published
- 2016-11
- Volume
- 29
- Issue
- 11
- Pages
- 1056-1065
- ISSN
- 0894-7317 (ISSN-L)
- OpenAlex
- W2520111962
- Cited by
- 192
- References
- 18
- FWCI
- 14.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.