The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Employing PCA and t-statistical approach for feature extraction and classification of emotion from multichannel EEG signal
Open accessAbstract
To achieve a highly efficient brain-computer interface (BCI) system regarding emotion recognition from electroencephalogram (EEG) signal, the most crucial issues are feature extractions and classifier selection. This work proposes an innovative method that hybridizes the principal component analysis (PCA) and t-statistics for feature extraction. This work contributes to successfully implement spatial PCA to reduce signal dimensionality and to select the suitable features based on the t-statistical inferences among the classes. The proposed method has been applied on the SEED dataset (SJTU Emotion EEG Dataset) that yielded significant channels and features for getting higher classification accuracy. With extracted features, four classifiers– support vector machine (SVM), artificial neural network (ANN), linear discriminant analysis (LDA), and k-nearest neighbor (kNN) method were applied to classify the emotional states. The classifiers showed slightly different classification accuracies compared to each other. ANN and SVM showed the highest classification accuracy (86.57 ± 4.08 and 85.85 ± 5.72) in case of subject dependent approach. On the other hand, the proposed method provides 84.3% and 77.1% classification accuracy with ANN and SVM, respectively in case of subject independent approach. Eventually, the proposed method and its outcomes demonstrate that this proposal is better than the several existing methods in emotion recognition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detecting Stress During Real-World Driving Tasks Using Physiological Sensors
Healey, J. A., & Picard, R. W. (2005) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2005.848368 · Cited by 2,207
Emotions Recognition Using EEG Signals: A Survey
Alarcao, S. M., & Fonseca, M. J. (2019) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2017.2714671 · Cited by 1,201
(2002) · Springer Series in Statistics · doi:10.1007/b98835 · Cited by 919
EEG-Based Emotion Recognition Using Hierarchical Network With Subnetwork Nodes
Yang, Y., Wu, Q. M. J., Zheng, W.-L., & Lu, B.-L. (2018) · IEEE Transactions on Cognitive and Developmental Systems · doi:10.1109/tcds.2017.2685338 · Cited by 141
Cited by
Zebari, R., Abdulazeez, A., Zeebaree, D., Zebari, D., & Saeed, J. (2020) · Journal of Applied Science and Technology Trends · doi:10.38094/jastt1224 · Cited by 918
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
Qin, Y., Xu, Q., Kujala, T., Wang, X., & Cong, F. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.109535 · Cited by 1
Metadata
- Authors
- Asadur Rahman, M., Foisal Hossain, M., Hossain, M., & Ahmmed, R.
- Venue
- Egyptian Informatics Journal
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 21
- Issue
- 1
- Pages
- 23-35
- ISSN
- 1110-8665 (ISSN-L)
- OpenAlex
- W2988016651
- Cited by
- 174
- References
- 4
- FWCI
- 20.98
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.