Formulation to target delivery to the ciliary body and choroid via the suprachoroidal space of the eye using microneedles
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In this work, we tested the hypothesis that particles injected into the suprachoroidal space can be localized at the site of injection or broadly distributed throughout the suprachoroidal space by controlling polymeric formulation properties. Single hollow microneedles were inserted into the sclera of New Zealand White rabbits and injected non-biodegradable fluorescently tagged nanoparticles and microparticles suspended in polymeric formulations into the suprachorodial space of the eye. When formulated in saline, the particles were distributed over 29% - 42% of the suprachoroidal space immediately after injection. To spread particles over larger areas of the choroidal surface, addition of hyaluronic acid to make moderately non-Newtonian solutions increased particle spread to up to 100% of the suprachoroidal space. To localize particles at the site of injection adjacent to the ciliary body, strongly non-Newtonian polymer solutions localized particles to 8.3% – 20% of the suprachoroidal space, which exhibited a small increase in area over the course of two months. This study demonstrates targeted particle delivery within the suprachoroidal space using polymer formulations that spread particles over the whole choroidal surface or localized them adjacent to the ciliary body after injection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gaudana, R., Ananthula, H. K., Parenky, A., & Mitra, A. K. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9183-3 · Cited by 1,406
Suprachoroidal drug delivery to the back of the eye using hollow microneedles
Patel, S. R., Lin, A. S. P., Edelhauser, H. F., & Prausnitz, M. R. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0271-y · Cited by 330 · cited 3×
“More recently, we introduced the use of microneedles for minimally invasive, targeted SCS injection [18, 19].”
Self-citationBressler, S. B. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.06.045 · Cited by 205 · cited 1×
“The two most common causes of blindness in industrialized nations are glaucoma, for which drugs often act on the ciliary body or trabecular meshwork [4, 5], and age-related macular degeneration (AMD), for which most drugs act on the choroid and/or retina [6, 7].”
Cannulation of the suprachoroidal space: a novel drug delivery methodology to the posterior segment
Olsen, T. W., Feng, X., Wabner, K., Conston, S. R., Sierra, D. H., Folden, D. V., Smith, M. E., & Cameron, J. D. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.05.045 · Cited by 171 · cited 1×
“For this reason, the SCS represents a promising new site of administration for treatment of many ocular diseases and has become a recent focus of drug delivery research [12-15].”
Olsen, T. W., Feng, X., Wabner, K., Csaky, K., Pambuccian, S., & Cameron, J. D. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6291 · Cited by 106 · cited 1×
“Initial attempts to access the suprachoroidal space involved invasive techniques such as catheters or implants that were surgically placed in the eye [13, 16, 17].”
Cited by
Microneedles as the technique of drug delivery enhancement in diverse organs and tissues
Rzhevskiy, A. S., Singh, T. R. R., Donnelly, R. F., & Anissimov, Y. G. (2018) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.11.048 · Cited by 266
Hyaluronic acid in ocular drug delivery
Zhang, X., Wei, D., Xu, Y., & Zhu, Q. (2021) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2021.118006 · Cited by 196
Drug delivery via the suprachoroidal space for the treatment of retinal diseases
Naftali Ben Haim, L., & Moisseiev, E. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13070967 · Cited by 68
“Material injected to the SCS was found to flow circumferentially [12,50,52] in a nonuniform pattern with the boundaries of specific anatomic structures—the scleral spur, the optic nerve and the short ciliary vessels [10–13].”
BackgroundSuprachoroidal gene transfer with nonviral nanoparticles
Shen, J., Kim, J., Tzeng, S. Y., Ding, K., Hafiz, Z., Long, D., Wang, J., Green, J. J., & Campochiaro, P. A. (2020) · Science Advances · doi:10.1126/sciadv.aba1606 · Cited by 63
Metadata
- Authors
- Kim, Y. C., Oh, K. H., Edelhauser, H. F., & Prausnitz, M. R.
- Venue
- European Journal of Pharmaceutics and Biopharmaceutics
- Publisher
- Elsevier BV
- Published
- 2015-09
- Volume
- 95
- Issue
- Pt B
- Pages
- 398-406
- ISSN
- 0939-6411 (ISSN-L)
- OpenAlex
- W606888720
- Cited by
- 65
- References
- 5
- FWCI
- 3.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.