Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 417

The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.

A novel electro analytical nanosensor based on graphene oxide/silver nanoparticles for simultaneous determination of quercetin and morin

Open access
Yola, Mehmet Lütfi, Gupta, Vinod Kumar, Eren, Tanju, Şen, Arif Emre, Atar, Necip·2014·Electrochimica Acta

Abstract

Abstract In this report, silver nanoparticles (AgNPs) with the mean diameters of 10-30 nm were self-assembled onto the surfaces of 2-aminoethanethiol (2-AET) functionalized graphene oxide (AETGO) sheets. The graphene oxide (GO) and AgNPs-AETGO nanocomposites were characterized by a transmission electron microscope (TEM), x-ray photoelectron spectroscopy (XPS), reflection–absorption infrared spectroscopy (RAIRS) and the x-ray diffraction (XRD). The simultaneous determination of quercetin (QR) and morin (MR) has been performed on glassy carbon electrode (GCE) modified with AgNPs-AETGO (AgNPs-AETGO/GCE). QR presented an oxidation step at Ea of 200 mV and reduction step at Ec of 150 mV and RT presented an oxidation step at Ea of 600 mV at AgNPs-AETGO/GCE by cyclic voltammetry (CV). The linearity ranges and the detection limits of QR and MR were 1.0 × 10-8 - 5.0 × 10-6 M and 3.3 × 10-9 M, respectively. The AgNPs-AETGO/GCE was also applied to real samples for the simultaneous determination of QR and MR. Thus the developed method can be adopted as an alternative to the published chromatographic, spectrophotometric and electroanalytical methods for simultaneous determination of QR and MR.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.electacta.2013.12.086

Cites

55 of 55 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 55 references

Metadata

Authors
Yola, M. L., Gupta, V. K., Eren, T., Şen, A. E., & Atar, N.
Venue
Electrochimica Acta
Publisher
Elsevier BV
Published
2014-02
Volume
120
Pages
204-211
ISSN
0013-4686 (ISSN-L)
OpenAlex
W2094864066
Cited by
417
References
55
FWCI
15.92
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A novel electro analytical nanosensor based on graphene oxide/silver nanoparticles for simultaneous determination of quercetin and morin. https://app.cochat.ai/papers/10.1016/j.electacta.2013.12.086
The paper
Yola, M. L., Gupta, V. K., Eren, T., Şen, A. E., & Atar, N. (2014). A novel electro analytical nanosensor based on graphene oxide/silver nanoparticles for simultaneous determination of quercetin and morin. Electrochimica Acta. https://doi.org/10.1016/j.electacta.2013.12.086

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.