The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Electrochemical detection of uric acid and ascorbic acid using r-GO/NPs based sensors
Open accessAbstract
ABSTRACT A sensitive and selective electrochemical sensor, based on reduced graphene oxide and gold nanoparticles obtained by simple co-electrodeposition, was developed for the detection of uric acid and ascorbic acid. Because of the electrochemical oxidation of both uric and ascorbic acid depending on the pH, the sensor performances were studied at different pH values. Excellent results were obtained for uric acid detection in a linear range from 10 to 500 µmol dm−3 with a sensitivity of 0.31 µA cm−2 µM−1. A limit of detection and quantification of 3.6 µM and 10.95 µmol dm−3, respectively, was calculated. Sensors showed good selectivity toward different interfering species present in the matrix of milk, fruit juice and urine (Na+, NH4+, Cl− and glucose). A simultaneous detection of uric acid and ascorbic acid was also carried out reaching a limit of detection of 2.26 and 5.63 µmol dm−3, respectively. Sensors were also validated measuring both acids in real samples of foods and body fluids (commercial milk and fruit juice and urine). Excellent results were achieved in good agreement with conventional techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Graphene Based Electrochemical Sensors and Biosensors: A Review
Shao, Y., Wang, J., Wu, H., Liu, J., Aksay, I. A., & Lin, Y. (2010) · Electroanalysis · doi:10.1002/elan.200900571 · Cited by 3,124
Anantharaj, S., Ede, S. R., Karthick, K., Sam Sankar, S., Sangeetha, K., Karthik, P. E., & Kundu, S. (2018) · Energy & Environmental Science · doi:10.1039/c7ee03457a · Cited by 1,632
Solid state chemistry and its applications
Beruto, D. (1984) · Materials Chemistry and Physics · doi:10.1016/0254-0584(84)90072-5 · Cited by 1,562
Solid State Chemistry and its Applications
West, A. R. (1984) · Cited by 1,494
Controlled Synthesis of Large‐Area and Patterned Electrochemically Reduced Graphene Oxide Films
Zhou, M., Wang, Y., Zhai, Y., Zhai, J., Ren, W., Wang, F., & Dong, S. (2009) · Chemistry – A European Journal · doi:10.1002/chem.200900596 · Cited by 815
Vitamin C in Human Health and Disease Is Still a Mystery? An Overview
Naidu, K. A. (2003) · Nutrition Journal · doi:10.1186/1475-2891-2-7 · Cited by 810
Synthesis and electrochemical applications of gold nanoparticles
Guo, S., & Wang, E. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.07.054 · Cited by 693
High Serum Uric Acid as a Novel Risk Factor for Type 2 Diabetes
Dehghan, A., van Hoek, M., Sijbrands, E. J. G., Hofman, A., & Witteman, J. C. M. (2008) · Diabetes Care · doi:10.2337/dc07-1276 · Cited by 652
Graphene-Based Electrochemical Sensors
Wu, S., He, Q., Tan, C., Wang, Y., & Zhang, H. (2013) · Small · doi:10.1002/smll.201202896 · Cited by 628
Recent Trends in Controlling the Enzymatic Browning of Fruit and Vegetable Products
Moon, K. M., Kwon, E.-B., Lee, B., & Kim, C. Y. (2020) · Molecules · doi:10.3390/molecules25122754 · Cited by 557
Metadata
- Authors
- Mazzara, F., Patella, B., Aiello, G., O'Riordan, A., Torino, C., Vilasi, A., & Inguanta, R.
- Venue
- Electrochimica Acta
- Publisher
- Elsevier BV
- Published
- 2021-08
- Volume
- 388
- Pages
- 138652
- ISSN
- 0013-4686 (ISSN-L)
- OpenAlex
- W3164375680
- Cited by
- 258
- References
- 37
- FWCI
- 11.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical detection of uric acid and ascorbic acid using r-GO/NPs based sensors. https://app.cochat.ai/papers/10.1016/j.electacta.2021.138652
- The paper
- Mazzara, F., Patella, B., Aiello, G., O'Riordan, A., Torino, C., Vilasi, A., & Inguanta, R. (2021). Electrochemical detection of uric acid and ascorbic acid using r-GO/NPs based sensors. Electrochimica Acta. https://doi.org/10.1016/j.electacta.2021.138652
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.