CoChat

An experimental study on the frosting characteristic and performance of a micro-channel evaporator in an air source heat pump unit

Hu, Wenju, Fan, Jin, Song, Mengjie, Jia, Peng, Gao, Yan · 2020 · Energy and Buildings

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Abstract

Abstract Frosting and refrigerant distribution uneven easily are two key problems restricting the wide application of micro-channel heat exchanger in the field of air source heat pump (ASHP). In this paper, frosting experiments were carried out on two kinds of micro-channel heat exchanger in three cases that with different refrigerant distribution characteristics. Frost and temperature distribution characteristics and their influence on the heat pump’s COP and heating capacity was studied. The results show distribution of refrigerant in heat exchanger directly affects the frost and temperature distribution on the surface of micro-channel heat exchanger, and affects the heating capacity and COP of ASHP greatly. Vertical placement of flat tubes and horizontal placement of the headers can be beneficial to the refrigerant distribution compared with that with the headers vertically placed. Flow direction of refrigerant in the heat exchanger must be from bottom to top to avoid deteriorated heat transfer performance and instability of ASHP. Difference between the lowest temperature and largest temperature on heat exchanger surface can be used as an index to judge whether ASHP works in high performance state.

Overview

Integrity signals

Registry

Crossref · 10.1016/j.enbuild.2020.110254

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 36 references

Research works printed but not linked: 1

  1. Wang, 2019, Experimental investigation on thermal characteristics of transcritical CO2 heat pump integrated with thermal energy storage for residential heating, Appl. Therm. Eng., 165

Cited by

Metadata

Authors
Hu, W., Fan, J., Song, M., Jia, P., & Gao, Y.
Affiliations
  • Beijing University of Civil Engineering and Architecture (CN)
  • Beijing Institute of Technology (CN)
Corresponding author
Song, Mengjie
Venue
Energy and Buildings
Publisher
Elsevier BV
Published
2020-10
Volume
224
Pages
110254
ISSN
0378-7788 (ISSN-L)
OpenAlex
W3038979120
Cited by
42
References
36
Citations by year
2026: 6 · 2025: 7 · 2024: 6 · 2023: 8 · 2022: 7 · 2021: 8
FWCI
2.59
Type
journal article
Language
en
Open access
closed
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
Energy and Buildings (publishedVersion)
Funders
Fundamental Research Funds for Beijing Universities (X18243, X18242)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Boiling Studies
Keywords
microchannel heat exchangers, air-source heat pump, frost formation, refrigerant distribution, coefficient of performance, heating capacity, tube orientation, temperature distribution

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.