Passive design optimization of low energy buildings in different climates
The DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
Abstract
Abstract Worldwide, the residential buildings are consuming a considerable amount of energy. The high potential of buildings towards energy efficiency has drawn special attention to the passive design parameters. A comprehensive study on optimal passive design for residential buildings is presented in this paper. Twenty-five different climates are simulated with the aim to produce best practices to reduce building energy demands (for cooling and heating) in addition to the life-cycle cost (LCC). The occupants' adaptive thermal comfort is also improved by implementing the appropriate passive cooling strategies such as blinds and natural ventilation. In this respect, the implemented methodology is composed of four phases: building energy simulation, optimization, Multi-criteria Decision Making (MCDM), sensitivity study, and finally an adaptive comfort analysis. An optimal passive solution of the studied building indicates the potential to save up to 54%, 87% and 52% of the cooling demands (Qcool), heating demands (Qheat) and LCC respectively with respect to the initial configuration. The obtained optimal passive parameters are validated with the National Renewable Energy Laboratory NREL benchmark for low energy building's envelope. Additionally, the integrated passive cooling strategies have demonstrated its competency since it leads to a significant overheating decrease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A fast and elitist multiobjective genetic algorithm: NSGA-II
Deb, K., Pratap, A., Agarwal, S., & Meyarivan, T. (2002) · IEEE Transactions on Evolutionary Computation · doi:10.1109/4235.996017 · Cited by 50,053
World map of the Köppen-Geiger climate classification updated
Kottek, M., Grieser, J., Beck, C., Rudolf, B., & Rubel, F. (2006) · Meteorologische Zeitschrift · doi:10.1127/0941-2948/2006/0130 · Cited by 11,456
The analytic hierarchy process—what it is and how it is used
Saaty, R. W. (1987) · Mathematical Modelling · doi:10.1016/0270-0255(87)90473-8 · Cited by 5,380
Thermal comfort and building energy consumption implications—A review
Yang, L., Yan, H., & Lam, J. C. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.10.062 · Cited by 1,448
A review on simulation-based optimization methods applied to building performance analysis
Nguyen, A.-T., Reiter, S., & Rigo, P. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.08.061 · Cited by 1,379
A review of computational optimisation methods applied to sustainable building design
Evins, R. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.02.004 · Cited by 777
Magnier, L., & Haghighat, F. (2010) · Building and Environment · doi:10.1016/j.buildenv.2009.08.016 · Cited by 725
Analysis of Particle Swarm Optimization Algorithm
Bai, Q. (2010) · Computer and Information Science · doi:10.5539/cis.v3n1p180 · Cited by 724
Algorithms for optimization of building design: A review
Machairas, V., Tsangrassoulis, A., & Axarli, K. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.11.036 · Cited by 682
Asadi, E., Silva, M. G. D., Antunes, C. H., Dias, L., & Glicksman, L. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.06.009 · Cited by 523
Delgarm, N., Sajadi, B., Kowsary, F., & Delgarm, S. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.02.141 · Cited by 500
Genetic-algorithm based approach to optimize building envelope design for residential buildings
Tuhus-Dubrow, D., & Krarti, M. (2010) · Building and Environment · doi:10.1016/j.buildenv.2010.01.005 · Cited by 495
Overview of NSGA-II for Optimizing Machining Process Parameters
Yusoff, Y., Ngadiman, M. S., & Zain, A. M. (2011) · Procedia Engineering · doi:10.1016/j.proeng.2011.08.745 · Cited by 478
Uncertainty analysis in building performance simulation for design support
Hopfe, C. J., & Hensen, J. L. M. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.06.034 · Cited by 457
Yu, W., Li, B., Jia, H., Zhang, M., & Wang, D. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2014.11.063 · Cited by 450
Hamdy, M., Nguyen, A.-T., & Hensen, J. L. M. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.03.035 · Cited by 325
Gou, S., Nik, V. M., Scartezzini, J.-L., Zhao, Q., & Li, Z. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2017.09.095 · Cited by 313
Asadi, E., da Silva, M. G., Antunes, C. H., & Dias, L. C. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.04.005 · Cited by 305
Case study of zero energy house design in UK
Wang, L., Gwilliam, J., & Jones, P. (2009) · Energy and Buildings · doi:10.1016/j.enbuild.2009.07.001 · Cited by 282
Lu, Y., Wang, S., & Shan, K. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.06.007 · Cited by 251
Carlucci, S., Cattarin, G., Causone, F., & Pagliano, L. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.06.064 · Cited by 248
Wu, Y., Zhang, J., Yuan, J., Geng, S., & Zhang, H. (2016) · Energy Conversion and Management · doi:10.1016/j.enconman.2016.01.020 · Cited by 244
A simulation-based optimization method for cost-optimal analysis of nearly Zero Energy Buildings
Ferrara, M., Fabrizio, E., Virgone, J., & Filippi, M. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.08.031 · Cited by 236
Multi-objective optimization methodology for net zero energy buildings
Harkouss, F., Fardoun, F., & Biwole, P. H. (2018) · Journal of Building Engineering · doi:10.1016/j.jobe.2017.12.003 · Cited by 233
Self-citationEnergy audit of building systems an engineering approach
Krarti, M. (2011) · Thammasat University Digital Collections · Cited by 229
Optimization of envelope and HVAC systems selection for residential buildings
Bichiou, Y., & Krarti, M. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.08.031 · Cited by 226
Delgarm, N., Sajadi, B., Delgarm, S., & Kowsary, F. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.05.052 · Cited by 226
Ascione, F., Bianco, N., De Stasio, C., Mauro, G. M., & Vanoli, G. P. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.04.078 · Cited by 219
Ascione, F., De Masi, R. F., de Rossi, F., Ruggiero, S., & Vanoli, G. P. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.09.027 · Cited by 210
Multi-objective optimization of building envelope design for life cycle environmental performance
Azari, R., Garshasbi, S., Amini, P., Rashed-Ali, H., & Mohammadi, Y. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.05.054 · Cited by 201
Delgarm, N., Sajadi, B., & Delgarm, S. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.09.003 · Cited by 199
Impact of different thermal comfort models on zero energy residential buildings in hot climate
Attia, S., & Carlucci, S. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.05.017 · Cited by 198
A learning-guided multi-objective evolutionary algorithm for constrained portfolio optimization
Lwin, K., Qu, R., & Kendall, G. (2014) · Applied Soft Computing · doi:10.1016/j.asoc.2014.08.026 · Cited by 193
Building information modeling based building design optimization for sustainability
Liu, S., Meng, X., & Tam, C. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.06.037 · Cited by 192
Bre, F., & Fachinotti, V. D. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.08.002 · Cited by 180
Hashemi, S. S., Hajiagha, S. H. R., Zavadskas, E. K., & Mahdiraji, H. A. (2016) · Applied Mathematical Modelling · doi:10.1016/j.apm.2015.08.011 · Cited by 161
Corrente, S., Figueira, J. R., Greco, S., & Słowiński, R. (2016) · Omega · doi:10.1016/j.omega.2016.11.008 · Cited by 149
ELECTRE III model for value engineering applications
Marzouk, M. M. (2010) · Automation in Construction · doi:10.1016/j.autcon.2010.11.026 · Cited by 144
Design optimisation for a low energy home in Sydney
Bambrook, S., Sproul, A. B., & Jacob, D. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.03.013 · Cited by 142
Residential adaptive comfort in a humid subtropical climate—Sydney Australia
de Dear, R., Kim, J., & Parkinson, T. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.11.028 · Cited by 142
Norese, M. F. (2004) · Land Use Policy · doi:10.1016/j.landusepol.2004.08.009 · Cited by 142
ELECTRE methods in prioritized MCDM environment
Yu, X., Zhang, S., Liao, X., & Qi, X. (2017) · Information Sciences · doi:10.1016/j.ins.2017.09.061 · Cited by 136
Design optimization of office building envelope configurations for energy conservation
Lin, Y., Tsai, K.-T., Lin, M., & Yang, M. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.03.018 · Cited by 135
Towards net zero energy design for low-rise residential buildings in subtropical Hong Kong
Fong, K. F., & Lee, C. K. (2012) · Applied Energy · doi:10.1016/j.apenergy.2012.01.006 · Cited by 131
Mobo A New Software For Multi-objective Building Performance Optimization
Palonen, M., Hamdy, M., & Hasan, A. (2013) · Building Simulation Conference proceedings · doi:10.26868/25222708.2013.1489 · Cited by 130
2014 Building America House Simulation Protocols
National Renewable Energy Lab. (NREL), G., Wilson, E., Building Technologies Office (EE-5B) USDOE Office of Energy Efficiency and Renewable Energy (EERE), Engebrecht-Metzger, C., Horowitz, S., & Hendron, R. (2014) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1126820 · Cited by 127
Iniestra, J. G., & Gutiérrez, J. G. (2008) · Applied Soft Computing · doi:10.1016/j.asoc.2008.07.006 · Cited by 125
Evaluation of net-zero energy residential buildings in the MENA region
Krarti, M., & Ihm, P. (2016) · Sustainable Cities and Society · doi:10.1016/j.scs.2016.02.007 · Cited by 116
Yang, M., Lin, M., Lin, Y., & Tsai, K.-T. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2016.01.015 · Cited by 113
A cost optimization model for 100% renewable residential energy supply systems
Milan, C., Bojesen, C., & Nielsen, M. P. (2012) · Energy · doi:10.1016/j.energy.2012.05.034 · Cited by 110
Adaptive thermal comfort in university dormitories in the severe cold area of China
Ning, H., Wang, Z., Zhang, X., & Ji, Y. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.01.003 · Cited by 107
Żak, J., & Kruszyński, M. (2015) · Transportation research procedia · doi:10.1016/j.trpro.2015.09.035 · Cited by 97
Internal Versus External Shading Devices Performance in Office Buildings
Atzeri, A. M., Cappelletti, F., & Gasparella, A. (2014) · Energy Procedia · doi:10.1016/j.egypro.2014.01.050 · Cited by 89
Karaguzel, O. T., Zhang, R., & Lam, K. P. (2013) · Building Simulation · doi:10.1007/s12273-013-0128-5 · Cited by 79
Seddiki, M., Anouche, K., Bennadji, A., & Boateng, P. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.08.023 · Cited by 79
A genetic algorithm for optimization of building envelope and HVAC system parameters
Palonen, M., Hasan, A., & Sirén, K. (2009) · Cited by 76
Kerdan, I. G., Raslan, R., & Ruyssevelt, P. A. (2016) · Energy · doi:10.1016/j.energy.2016.06.041 · Cited by 69
Zhang, Y., Zhang, Y., Shi, W., Shang, R., Cheng, R., & Wang, X. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.016 · Cited by 68
Yang, M., Chen, Y.-P., Lin, Y., Ho, Y.-F., & Lin, J.-Y. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.04.027 · Cited by 68
Evolutionary algorithms for multi-objective optimization in HVAC system control strategy
Nassif, N., Kajl, S., & Sabourin, R. (2004) · Annual Meeting of the North American Fuzzy Information Processing Society (NAFIPS) · doi:10.1109/nafips.2004.1336248 · Cited by 68
Net-zero and beyond! Design and performance of NIST's net-zero energy residential test facility
Fanney, A. H., Payne, V., Ullah, T., Ng, L. C., Boyd, M. T., Omar, F., Davis, M. W., Skye, H. M., Dougherty, B. P., Polidoro, B. J., et al. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.05.002 · Cited by 64
Harmathy, N., Magyar, Z., & Folić, R. (2016) · Energy · doi:10.1016/j.energy.2016.07.162 · Cited by 60
The Framework of an Optimization Model for Building Envelope
Lapinskienė, V., & Martinaitis, V. (2013) · Procedia Engineering · doi:10.1016/j.proeng.2013.04.085 · Cited by 56
Xu, W., Chong, A., Karaguzel, O. T., & Lam, K. P. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.06.043 · Cited by 53
Thapa, S., Bansal, A. K., & Panda, G. K. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.12.026 · Cited by 50
Development of power system designs for a net zero energy house
Hassoun, A., & Dinçer, İ. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.01.027 · Cited by 44
Ruellan, M., Park, H., & Bennacer, R. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.07.029 · Cited by 44
2014 Building America House Simulation Protocols
USDOE Office of Energy Efficiency and Renewable Energy (EERE), E. E. O. B. T. O., Wilson, E. J. H., Engebrecht, C., Horowitz, S., & Hendron, R. (2014) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1221086 · Cited by 42
Design Challenges of the NIST Net Zero Energy Residential Test Facility
Healy, W. M., Gates, C., Fanney, A. H., & Pettit, B. (2015) · doi:10.6028/nist.tn.1847 · Cited by 37
Probabilistic adaptive thermal comfort for resilient design
Coley, D., Herrera, M., Fosas, D., Liu, C., & Vellei, M. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.06.050 · Cited by 32
Cited by
Effects of moderate thermal environments on cognitive performance: A multidisciplinary review
Zhang, F., de Dear, R., & Hancock, P. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.12.005 · Cited by 217
Simulation optimisation towards energy efficient green buildings: Current status and future trends
Gan, V. J. L., Lo, I. M. C., Ma, J., Tse, K. T., Cheng, J. C. P., & Chan, C. M. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.120012 · Cited by 194
Kuczyński, T., & Staszczuk, A. (2020) · Energy · doi:10.1016/j.energy.2020.116984 · Cited by 131
Metadata
- Authors
- Harkouss, F., Fardoun, F., & Biwole, P. H.
- Venue
- Energy
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 165
- Pages
- 591-613
- ISSN
- 0360-5442 (ISSN-L)
- OpenAlex
- W2892277348
- Cited by
- 247
- References
- 70
- FWCI
- 14.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.