Experimental study of the influence of thermal mass on thermal comfort and cooling energy demand in residential buildings

Open access
Kuczyński, T., Staszczuk, A.·2020·Energy

Abstract

The article presents the results of experimental research carried out in two real-scale detached energy-efficient single-family buildings designed to be almost identical with exempt to the construction of their external and internal walls; lightweight skeletal versus traditional masonry construction. The reduction of the average indoor temperature during the heatwave of August 2015 obtained by increasing the thermal mass of the building was 2.8 ± 0.34 °C, with the maximum value at the hottest part of the day being 3.4 °C. Replacing the lightweight frame structure of the walls with cellular concrete, in an exceptionally warm August, with an average outside temperature of 22.5 °C, shortened the total time of occurrence of indoor temperature higher than 28 °C from 18.6 days to only 8 h. The cooling effect of building thermal mass remained stable during all 14 days of heat wave with only slight diurnal variations. The total reduction in the cooling energy demand achieved was 67% at 25 °C set point temperature and 75% at set point temperature 26 °C respectively.

Integrity signals

Registry

Crossref · 10.1016/j.energy.2020.116984

Cites

70 of 70 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In a detached single-family house, the use of concrete ground floors and walls combined with nighttime ventilation and shading devices substantially reduces the risk of overheating and the need for active cooling systems.

    “In their analysis, the use of concrete ground floors and walls in a detached single-family house, combined with nighttime ventilation and shading devices, substantially reduces the risk of overheating and the need for the installation of active cooling systems.”

Cites

Flagged first, then by citations

1 of the 71 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Kuczyński, T., & Staszczuk, A.
Affiliations
University of Zielona Góra (PL)
Corresponding author
Staszczuk, A.
Venue
Energy
Publisher
Elsevier BV
Published
2020-03
Volume
195
Pages
116984
ISSN
0360-5442 (ISSN-L)
OpenAlex
W3000321042
Cited by
131
References
71
Citations by year
2026: 21 · 2025: 20 · 2024: 18 · 2023: 27 · 2022: 19 · 2021: 19 · 2020: 7
FWCI
9.54
Type
journal article
Language
en
Open access
Locations
  • Energy (publishedVersion, cc-by)
  • RePEc: Research Papers in Economics (submittedVersion)
Topics
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Physical Sciences › Engineering › Building and Construction › Building energy efficiency and sustainability
  • Physical Sciences › Engineering › Mechanical Engineering › Phase Change Materials Research
Keywords
building thermal mass, thermal comfort, cooling demand, residential buildings, foam concrete, masonry walls, heat waves, indoor temperature, setpoint temperature

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review