Brain-responsive neurostimulation for epilepsy (RNS® System)
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
System demonstrate that closed-loop responsive neurostimulation to the seizure focus reduces the frequency of disabling seizures, is well tolerated, and is acceptably safe. Seizure reductions begin with initiation of treatment and continue over time, reaching median reductions of 75% after 9 years of treatment. Treatment with responsive cortical stimulation is also associated with improvement in quality of life and cognitive function related to the functional area being treated. In addition, the RNS System's chronic ambulatory electrocorticographic monitoring provides unprecedented insight into each patient's disease management, and into the study of epilepsy itself, in ways that may enhance the treatment of epilepsy in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Responsive cortical stimulation for the treatment of medically intractable partial epilepsy
Morrell, M. J. (2011) · Neurology · doi:10.1212/wnl.0b013e3182302056 · Cited by 1,282
Self-citationHeck, C. N., King‐Stephens, D., Massey, A. D., Nair, D. R., Jobst, B. C., Barkley, G. L., Salanova, V., Cole, A. J., Smith, M. C., Gwinn, R. P., et al. (2014) · Epilepsia · doi:10.1111/epi.12534 · Cited by 651
Self-citationLong-term treatment with responsive brain stimulation in adults with refractory partial seizures
Bergey, G. K., Morrell, M. J., Mizrahi, E. M., Goldman, A., King-Stephens, D., Nair, D., Srinivasan, S., Jobst, B., Gross, R. E., Shields, D. C., et al. (2015) · Neurology · doi:10.1212/wnl.0000000000001280 · Cited by 634
Self-citationMulti-day rhythms modulate seizure risk in epilepsy
Baud, M. O., Kleen, J. K., Mirro, E. A., Andrechak, J. C., King-Stephens, D., Chang, E. F., & Rao, V. R. (2018) · Nature Communications · doi:10.1038/s41467-017-02577-y · Cited by 532
Geller, E. B., Skarpaas, T. L., Gross, R. E., Goodman, R. R., Barkley, G. L., Bazil, C. W., Berg, M. J., Bergey, G. K., Cash, S. S., Cole, A. J., et al. (2017) · Epilepsia · doi:10.1111/epi.13740 · Cited by 310
Self-citationJobst, B. C., Kapur, R., Barkley, G. L., Bazil, C. W., Berg, M. J., Bergey, G. K., Boggs, J. G., Cash, S. S., Cole, A. J., Duchowny, M. S., et al. (2017) · Epilepsia · doi:10.1111/epi.13739 · Cited by 245
Self-citationLateralization of mesial temporal lobe epilepsy with chronic ambulatory electrocorticography
King‐Stephens, D., Mirro, E., Weber, P. B., Laxer, K. D., Van Ness, P. C., Salanova, V., Spencer, D. C., Heck, C. N., Goldman, A., Jobst, B., et al. (2015) · Epilepsia · doi:10.1111/epi.13010 · Cited by 202
Self-citationLoring, D. W., Kapur, R., Meador, K. J., & Morrell, M. J. (2015) · Epilepsia · doi:10.1111/epi.13191 · Cited by 169
Self-citationSpencer, D. C., Sun, F. T., Brown, S. N., Jobst, B. C., Fountain, N. B., Wong, V. S. S., Mirro, E. A., & Quigg, M. (2016) · Epilepsia · doi:10.1111/epi.13455 · Cited by 160
Meador, K. J., Kapur, R., Loring, D. W., Kanner, A. M., & Morrell, M. J. (2015) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2015.01.012 · Cited by 141
Self-citation
Cited by
Forecasting seizure risk in adults with focal epilepsy: a development and validation study
Proix, T., Truccolo, W., Leguia, M. G., Tcheng, T. K., King-Stephens, D., Rao, V. R., & Baud, M. O. (2021) · The Lancet Neurology · doi:10.1016/s1474-4422(20)30396-3 · Cited by 179
Machine learning and wearable devices of the future
Beniczky, S., Karoly, P., Nurse, E., Ryvlin, P., & Cook, M. (2021) · Epilepsia · doi:10.1111/epi.16555 · Cited by 155
NeuroBus - Architecture for an Ultra-Flexible Neural Interface
Sporer, M., Vasilaş, I.-G., Adžemović, A., Graber, N., Reich, S., Gueli, C., Eickenscheidt, M., Diester, I., Stieglitz, T., & Ortmanns, M. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3354785 · Cited by 13
“The sealed base unit is either implanted in the cranial bone [14] or in the chest as in pacemakers and contains the neural recording interfacewithdigitizationaswellasadditionalcircuitryforwire-lesscommunication/powertransferandpowermanagement.”
Metadata
- Authors
- Skarpaas, T. L., Jarosiewicz, B., & Morrell, M. J.
- Venue
- Epilepsy Research
- Publisher
- Elsevier BV
- Published
- 2019-07
- Volume
- 153
- Pages
- 68-70
- ISSN
- 0920-1211 (ISSN-L)
- OpenAlex
- W2915802812
- Cited by
- 218
- References
- 16
- FWCI
- 17.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Brain-responsive neurostimulation for epilepsy (RNS® System). https://app.cochat.ai/papers/10.1016/j.eplepsyres.2019.02.003
- The paper
- Skarpaas, T. L., Jarosiewicz, B., & Morrell, M. J. (2019). Brain-responsive neurostimulation for epilepsy (RNS® System). Epilepsy Research. https://doi.org/10.1016/j.eplepsyres.2019.02.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.