This article presents the system architecture for an implant concept called NeuroBus. Tiny distributed direct digitizing neural recorder ASICs on an ultra-flexible polyimide substrate are connected in a bus-like structure, allowing short connections between electrode and recording front-end with low wiring effort and high customizability. The small size (344 μm × 294 μm) of the ASICs and the ultraflexible substrate allow a low bending stiffness, enabling the implant to adapt to the curvature of the brain and achieving high structural biocompatibility. We introduce the architecture, the integrated building blocks, and the post-CMOS processes required to realize a NeuroBus, and we characterize the prototyped direct digitizing neural recorder front-end as well as polyimide-based ECoG brain interface. A rodent animal model is further used to validate the joint capability of the recording front-end and thin-film electrode array.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Implementation of a remote wireless hub with tethered contacts to electrode sites helps overcome safety limitations of wireless powering and communication due to tissue heating and enables easy access to deeper tissue regions, while active, in-situ control of high-density electrodes enables use of fewer wires that improves interconnect reliability.
“The implementation of a remote wireless hub with tethered contacts to the electrode sites helps overcome the safety limitations of wireless powering and communication due to tissue heating and enables easy access to deeper tissue regions, while the active, in-situ control of high-density electrodes enables the use of fewer wires that improves interconnect reliability [76].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [76]
Cites
The dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,168 · see citing works
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243 · see citing works
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078 · see citing works
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · see citing works
An economical class of digital filters for decimation and interpolation
Hogenauer, E. (1981) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1981.1163535 · Cited by 1,190 · see citing works
Neuropixels 2.0: A miniaturized high-density probe for stable, long-term brain recordings.
Steinmetz, N. A., Aydin, C., Lebedeva, A., Okun, M., Pachitariu, M., Bauza, M., Beau, M., Bhagat, J., Böhm, C., Broux, M., et al. (2021) · Science · doi:10.1126/science.abf4588 · Cited by 1,173 · cited 2× · see citing works
“These devices are equipped with head mounted connectors [16], [21] since they are rather intended for short to medium term fundamental neuroscience applications [17] than for translational research and chronic use in humans.”
BackgroundNeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938 · see citing works
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862 · see citing works
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600 · see citing works
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557 · see citing works
Invasive recordings from the human brain: clinical insights and beyond
Engel, A. K., Moll, C. K. E., Fried, I., & Ojemann, G. A. (2004) · Nature reviews. Neuroscience · doi:10.1038/nrn1585 · Cited by 409 · see citing works
Moshayedi, P., Ng, G., Kwok, J. C. F., Yeo, G. S. H., Bryant, C. E., Fawcett, J. W., Franze, K., & Guck, J. R. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.01.038 · Cited by 382 · see citing works
Muller, R., Gambini, S., & Rabaey, J. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2163552 · Cited by 338 · see citing works
Responsive Cortical Stimulation for the Treatment of Epilepsy
Sun, F. T., Morrell, M. J., & Wharen, R. E. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.069 · Cited by 310 · see citing works
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310 · see citing works
Recent Progress in Aromatic Polyimide Dielectrics for Organic Electronic Devices and Circuits
Ji, D., Li, T., Hu, W., & Fuchs, H. (2019) · Advanced Materials · doi:10.1002/adma.201806070 · Cited by 297 · see citing works
Continuous-Time Sigma-Delta A/D Conversion
Ortmanns, M., & Gerfers, F. (2006) · Springer eBooks · doi:10.1007/3-540-28473-7 · Cited by 282 · see citing works
Self-citationClock jitter and quantizer metastability in continuous-time delta-sigma modulators
Cherry, J. A., & Snelgrove, W. M. (1999) · IEEE Transactions on Circuits and Systems II Analog and Digital Signal Processing · doi:10.1109/82.769775 · Cited by 232 · see citing works
Brain-responsive neurostimulation for epilepsy (RNS® System)
Skarpaas, T. L., Jarosiewicz, B., & Morrell, M. J. (2019) · Epilepsy Research · doi:10.1016/j.eplepsyres.2019.02.003 · Cited by 219 · see citing works
A Neural Probe With Up to 966 Electrodes and Up to 384 Configurable Channels in 0.13 $\mu$m SOI CMOS
López, C. M., Putzeys, J., Raducanu, B. C., Ballini, M., Wang, S., Andrei, A., Rochus, V., Vandebriel, R., Severi, S., Hoof, C. A. V., et al. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2646901 · Cited by 198 · see citing works
Rail-to-Rail-Input Dual-Radio 64-Channel Closed-Loop Neurostimulator
Kassiri, H., Salam, M. T., Pazhouhandeh, M. R., Soltani, N., Velázquez, J. L. P., Carlen, P. L., & Genov, R. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2749426 · Cited by 160 · see citing works
A low-power, low-noise CMOS amplifier for neural recording applications
Harrison, R. R. (2003) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2002.1010674 · Cited by 155 · see citing works
Neuropixels 2.0: A miniaturized high-density probe for stable, long-term brain recordingsPreprint
Steinmetz, N. A., Aydın, Ç., Lebedeva, A., et al. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.10.27.358291 · Cited by 150 · see citing works
A Sub-mm 3 Ultrasonic Free-Floating Implant for Multi-Mote Neural Recording
Ghanbari, M. M., Piech, D. K., Shen, K., Alamouti, S. F., Yalcin, C., Johnson, B. C., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2936303 · Cited by 137 · see citing works
Chandrakumar, H., & Markovic, D. M. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2876468 · Cited by 135 · see citing works
Keller, M., Buhmann, A., Sauerbrey, J., Ortmanns, M., & Manoli, Y. (2008) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2008.925362 · Cited by 132 · see citing works
Self-citationRobust Wireless Power Transmission to mm-Sized Free-Floating Distributed Implants
Mirbozorgi, S. A., Yeon, P., & Ghovanloo, M. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2663358 · Cited by 128 · see citing works
Johnson, B. C., Gambini, S., Izyumin, I., Moin, A., Zhou, A., Alexandrov, G., Santacruz, S. R., Rabaey, J. M., Carmena, J. M., & Muller, R. (2017) · 2017 Symposium on VLSI Circuits · doi:10.23919/vlsic.2017.8008543 · Cited by 119 · see citing works
A CMOS Chip With Active Pixel Array and Specific Test Features for Subretinal Implantation
Rothermel, A., Liu, L., Aryan, N. P., Fischer, M. D., Wuenschmann, J., Kibbel, S., & Harscher, A. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2007436 · Cited by 109 · see citing works
Emerging Encapsulation Technologies for Long-Term Reliability of Microfabricated Implantable Devices
Ahn, S.-H., Jeong, J., & Kim, S. J. (2019) · Micromachines · doi:10.3390/mi10080508 · Cited by 109 · see citing works
Incremental Delta-Sigma ADCs: A Tutorial Review
Tan, Z., Chen, C., Chae, Y., & Temes, G. C. (2020) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2020.3033458 · Cited by 108 · see citing works
Lee, C., Jeon, T., Jang, M., Park, S., Kim, J., Lim, J., Ahn, J., Huh, Y., & Chae, Y. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.3018478 · Cited by 105 · see citing works
Intracranial Stimulation Therapy for Epilepsy
Skarpaas, T. L., & Morrell, M. J. (2009) · Neurotherapeutics · doi:10.1016/j.nurt.2009.01.022 · Cited by 104 · see citing works
Kim, C., Joshi, S., Courellis, H., Wang, J., Miller, C., & Cauwenberghs, G. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2870555 · Cited by 104 · see citing works
Jeong, J., Laiwalla, F., Lee, J.-H., Ritasalo, R., Pudas, M., Larson, L. E., Leung, V., & Nurmikko, A. V. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201806440 · Cited by 96 · see citing works
Conformable polyimide-based μECoGs: Bringing the electrodes closer to the signal source
Vomero, M., Porto Cruz, M. F., Zucchini, E., Ciarpella, F., Delfino, E., Carli, S., Boehler, C., Asplund, M., Ricci, D., Fadiga, L., et al. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120178 · Cited by 95 · see citing works
Self-citationDorigo, D. D., Moranz, C., Graf, H., Marx, M., Wendler, D., Shui, B., Herbawi, A. S., Kuhl, M., Ruther, P., Paul, O., et al. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2873180 · Cited by 94 · see citing works
Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording
Deku, F., Cohen, Y., Joshi-Imre, A., Kanneganti, A., Gardner, T. J., & Cogan, S. F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8f8b · Cited by 89 · see citing works
Wang, S., López, C. M., Garakoui, S. K., Chun, H., Gómez, D., Sijbers, W., Putzeys, J., Martens, E., Craninckx, J., & Helleputte, N. V. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2942450 · Cited by 81 · see citing works
Chronic tissue response to untethered microelectrode implants in the rat brain and spinal cord
Erşen, A., Elkabes, S., Freedman, D. S., & Şahin, M. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016019 · Cited by 64 · see citing works
An Implantable Wireless Network of Distributed Microscale Sensors for Neural Applications
Lee, J., Lee, F., Huang, J., Cui, L., Lee, A.-H., Leung, V., Mercier, P., Shellhammer, S., Larson, L., Asbeck, P., et al. (2019) · 2019 9th International IEEE/EMBS Conference on Neural Engineering (NER) · doi:10.1109/ner.2019.8717023 · Cited by 54 · see citing works
Nikas, A., Jambunathan, S., Klein, L., Voelker, M., & Ortmanns, M. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2931811 · Cited by 45 · see citing works
Self-citationA 0.01-mm 2 Mostly Digital Capacitor-Less AFE for Distributed Autonomous Neural Sensor Nodes
Huang, J., Laiwalla, F., Lee, J.-H., Cui, L., Leung, V., Nurmikko, A. V., & Mercier, P. P. (2018) · IEEE Solid-State Circuits Letters · doi:10.1109/lssc.2019.2894932 · Cited by 44 · see citing works
Wendler, D., Dorigo, D. D., Amayreh, M., Bleitner, A., Marx, M., Willaredt, R., & Manoli, Y. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2022.3190446 · Cited by 44 · see citing works
A High-Voltage Compliance, 32-Channel Digitally Interfaced Neuromodulation System on Chip
Reich, S., Sporer, M., Haas, M., Becker, J., Schüettler, M., & Ortmanns, M. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3076510 · Cited by 41 · see citing works
Self-citationPochet, C., Huang, J., Mercier, P. P., & Hall, D. A. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3133531 · Cited by 40 · see citing works
Incremental Delta-Sigma Structures for DC Measurement: an Overview
Márkus, J., Deval, P., Quiquempoix, V., Silva, J., & Temes, G. C. (2006) · Custom Integrated Circuits Conference · doi:10.1109/cicc.2006.320960 · Cited by 39 · see citing works
Fabrication of a Monolithic Implantable Neural Interface from Cubic Silicon Carbide
Beygi, M., Bentley, J. T., Frewin, C. L., Kuliasha, C. A., Takshi, A. I., Bernardin, E. K., Via, F. L., & Saddow, S. E. (2019) · Micromachines · doi:10.3390/mi10070430 · Cited by 38 · see citing works
Mokhtar, M. A., Vogelmann, P., Haas, M., & Ortmanns, M. (2019) · IEEE Solid-State Circuits Letters · doi:10.1109/lssc.2019.2930172 · Cited by 38 · see citing works
Self-citationAn AC-Coupled 1st-Order Δ-ΔΣ Readout IC for Area-Efficient Neural Signal Acquisition
Yang, X., Ballini, M., Sawigun, C., Hsu, W.-Y., Weijers, J.-W., Putzeys, J., & López, C. M. (2023) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2023.3234612 · Cited by 38 · see citing works
Vomero, M., Castagnola, E., Ordonez, J. S., Carli, S., Zucchini, E., Maggiolini, E., Gueli, C., Goshi, N., Ciarpella, F., Cea, C., et al. (2017) · Advanced Biosystems · doi:10.1002/adbi.201700081 · Cited by 32 · see citing works
Self-citationTelemetry for Implantable Medical Devices: Part 1 - Media Properties and Standards
Ritter, R., Handwerker, J., Liu, T., & Ortmanns, M. (2014) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2014.2315052 · Cited by 27 · see citing works
Self-citationFour-Wire Interface ASIC for a Multi-Implant Link
Ghoreishizadeh, S. S., Haci, D., Liu, Y., Donaldson, N., & Constandinou, T. G. (2017) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2017.2731659 · Cited by 26 · see citing works
Synchrony surfacing: Epicortical recording of correlated action potentials
Bockhorst, T., Pieper, F., Engler, G., Stieglitz, T., Galindo-Leon, E. E., & Engel, A. K. (2018) · European Journal of Neuroscience · doi:10.1111/ejn.14167 · Cited by 25 · see citing works
Self-citationA Direct Digitizing Chopped Neural Recorder Using a Body-Induced Offset Based DC Servo Loop
Sporer, M., Reich, S., Kauffman, J. G., & Ortmanns, M. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3177241 · Cited by 24 · see citing works
Self-citationAn AC-powered optical receiver consuming 270μW for transcutaneous 2Mb/s data transfer
Lange, S., Xu, H., Lang, C., Pless, H., Becker, J., Tiedkte, H.-J., Hennig, E., & Ortmanns, M. (2011) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2011.5746329 · Cited by 22 · see citing works
Self-citationBattery-less modular responsive neurostimulator for prediction and abortion of epileptic seizures
Kassiri, H., Soltani, N., Salam, M. T., Velázquez, J. L. P., & Genov, R. (2016) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2016.7527486 · Cited by 22 · see citing works
Amorphous silicon carbide films by plasma-enhanced chemical vapor deposition
Tong, L., Mehregany, M., & Tang, W. C. (2002) · Proceedings, IEEE micro electro mechanical systems · doi:10.1109/memsys.1993.296915 · Cited by 14 · see citing works
Design theory for high-order incremental converters
Márkus, J., Silva, J., & Temes, G. C. (2004) · IEEE International Symposium on Intelligent Signal Processing, · doi:10.1109/isp.2003.1275804 · Cited by 12 · see citing works
Somappa, L., & Baghini, M. S. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3098722 · Cited by 12 · see citing works
Passlack, U., Simon, N., Bucher, V., Harendt, C., Stieglitz, T., & Burghartz, J. N. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.2c22513 · Cited by 12 · see citing works
Self-citationHighly conformable chip-in-foil implants for neural applications
Stieglitz, T., Gueli, C., Martens, J., Floto, N., Eickenscheidt, M., Sporer, M., & Ortmanns, M. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00527-x · Cited by 12 · see citing works
Self-citationSzabo, B., Gueli, C., Eickenscheidt, M., & Stieglitz, T. (2020) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2020-3124 · Cited by 11 · see citing works
Self-citationImplantable Device Fabrication and Packaging
Stieglitz, T. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_102 · Cited by 7 · see citing works
Self-citationPavan, S. (2018) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2018.2820017 · Cited by 5 · see citing works
Design Considerations for Ground Referencing in Multi - Module Neural Implants
Haci, D., Liu, Y., Ghoreishizadeh, S. S., & Constandinou, T. G. (2018) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2018.8584708 · Cited by 5 · see citing works
Gueli, C., Martens, J., Eickenscheidt, M., & Stieglitz, T. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630832 · Cited by 5 · see citing works
Self-citationNeuroBus – Architecture and Communication Bus for an Ultra-Flexible Neural Interface
Sporer, M., Graber, N., Reich, S., Gueli, C., Becker, J., Stieglitz, T., & Ortmanns, M. (2023) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas46773.2023.10181816 · Cited by 5 · see citing works
Self-citationIn-body wireline interfacing platform for multi-module implantable microsystems
Haci, D., Mifsud, A., Liu, Y., Ghoreishizadeh, S. S., & Constandinou, T. G. (2019) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2019.8918756 · Cited by 4 · see citing works
A 1-Wire® communication interface between a control hub and locally powered epidural stimulators
Eder, C. F., Valente, V., Donaldson, N., & Demosthenous, A. (2013) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2013.6679677 · Cited by 2 · see citing works
A 100-mVpp Input Range 10-kHz BW VCO-based CT-DSM Neuro-Recording IC in 40-nm CMOS
Zhou, W., Goh, W. L., Chen, Y., Zhang, T., & Gao, Y. (2019) · IEEE International System-on-Chip Conference (SOCC) · doi:10.1109/socc46988.2019.1570553458 · Cited by 2 · see citing works
Capacitive coupled full-wave rectifier for rectangular power signals
Kaim, H., Brendler, C., Rieger, V., & Rothermel, A. (2015) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2015.7348293 · Cited by 1 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Nanbakhsh, K., Idil, A. S., Lamont, C. A., Dücső, C., Akgun, Ö. C., Horváth, D., Tóth, K., Meszéna, D., Ulbert, I., Mazza, F., et al. (2025) · Nature Communications · doi:10.1038/s41467-024-55298-4 · Cited by 43 · see citing works
Highly conformable chip-in-foil implants for neural applications
Stieglitz, T., Gueli, C., Martens, J., Floto, N., Eickenscheidt, M., Sporer, M., & Ortmanns, M. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00527-x · Cited by 12 · see citing works
Self-citationActive Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11 · see citing works
“…sites helps overcome the safety limitations of wireless powering and communication due to tissue heating and enables easy access to deeper tissue regions, while the active, in-situ control of high-density electrodes enables the use of fewer wires that improves interconnect reliability [76].”
A Wide-Dynamic-Range, DC-Coupled, Time-Based Neural-Recording IC With Optimized CCO Frequency
Youn, D., Kim, Y.-I., Choi, I., Jung, Y., Jeon, H., Lee, K., Kweon, S.-J., Ha, S., & Je, M. (2024) · IEEE Access · doi:10.1109/access.2024.3424228 · Cited by 3 · see citing works
An ultra-miniaturized Neural Recording μASIC for the NeuroBus Implant
Sporer, M., Graber, N., Mayer, M., Reich, S., Stieglitz, T., & Ortmanns, M. (2024) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas61083.2024.10798303 · Cited by 3 · see citing works
Self-citationHuang, X., & Muratore, D. G. (2025) · Custom Integrated Circuits Conference · doi:10.1109/cicc63670.2025.10983696 · Cited by 2 · see citing works
Ma, L., Chen, B., Zhang, W. L., Guo, T., Han, X., Wang, D., Wang, H. S., & Liang, C. (2026) · Applied Surface Science · doi:10.1016/j.apsusc.2026.165854 · Cited by 2 · see citing works
Diez-Clos, A., Huang, X., Monna, B., & Muratore, D. G. (2025) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas56072.2025.11044232 · Cited by 1 · see citing works
Incremental ∆Σ ADCs without Periodic Reset
Ismail, O., Kaesser, P., Sporer, M., Kauffman, J. G., & Ortmanns, M. (2025) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas56072.2025.11043980 · Cited by 1 · see citing works
Self-citationReducing the Impact of Non-Idealities on Incremental Δ∑ ADCs by Reconfiguration: A Review
Ismail, O., Kaesser, P., & Ortmanns, M. (2025) · Custom Integrated Circuits Conference · doi:10.1109/cicc63670.2025.10983744
Self-citationLow-Power Closed-Loop iBCI System: Prototype Design and Safety Evaluation
Starikov, I. (2026) · 2026 ElCon Conference of Young Researchers in Communication and Networking, Signal Processing & Analysis, Biomedical and Environmental Engineering (ElCon-CN) · doi:10.1109/elcon-cn69892.2026.11414060
Zhong, M., Chen, W., Wan, P., Chen, Z., & Liu, X. (2026) · Microelectronics Journal · doi:10.1016/j.mejo.2026.107336
Distributed Wireless Neural Recording System for Multi-Region Brain Activity Monitoring
Yang, L., You, C., Wang, G., Zhang, X., Wang, C., Cheng, B., Zhao, Z., Xue, N., & Yao, L. (2026) · Biosensors · doi:10.3390/bios16070370
- Authors
- Sporer, M., Vasilaş, I.-G., Adžemović, A., Graber, N., Reich, S., Gueli, C., Eickenscheidt, M., Diester, I., Stieglitz, T., & Ortmanns, M.
- Affiliations
- Universität Ulm (DE)
- BrainLinks-BrainTools//IMBIT, Freiburg, Germany
- University of Freiburg (DE)
- ORCID
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2024-04
- Volume
- 18
- Issue
- 2
- Pages
- 247-262
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W4390908050
- Cited by
- 13
- References
- 71
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 3 · 2023: 1
- FWCI
- 2.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- IEEE Transactions on Biomedical Circuits and Systems (publishedVersion, cc-by)
- PubMed (publishedVersion)
- OPen Access Repositorium der Universität Ulm (OPARU) (Ulm University) (submittedVersion, cc-by)
- Funders
- German National Science Foundation (OR 245/15-1, EI 1078/1-1)
- European School of Network Neuroscience
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › CCD and CMOS Imaging Sensors
- Keywords
- neural interfaces, implantable neural recording, ASIC, thin film electrodes, electrocorticography, biocompatibility, rodent models
- MeSH terms
- Electrocorticography, Animals, Brain, Electrodes, Head
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review