Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 269

The DOI matches its Crossref record; 163 of the 163 references it cites were found in a registry or an index.

Influence of operational and design parameters on the performance of a PCM based heat exchanger for thermal energy storage – A review

Kalapala, Lokesh, Devanuri, Jaya Krishna·2018·Journal of Energy Storage

Abstract

Abstract Thermal energy storage using phase change materials (PCM) proved to be a promising technology because of its relative advantages over the other types of energy storage methods. Along with thermophysical properties of PCM, the performance of latent heat based thermal energy storage system depends on the design of the heat exchanger. Although extensive research is being carried out over the past few years, an integrated study on the design of PCM heat exchanger is scarce. This review presents the in-depth analysis of various operating conditions and design parameters that need to be considered in the design of a PCM based heat exchanger. Shell and tube type, triple concentric tube type heat exchangers are discussed along with the various heat transfer techniques employed in both the types of heat exchangers. In each enhancement technique, the influencing geometric parameters are summarized, and the recommended values of those parameters are provided. The present article is expected to be a helpful reference for the researchers working in the field of thermal energy storage.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.est.2018.10.024

Cites

163 of 163 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 269

Metadata

Authors
Kalapala, L., & Devanuri, J. K.
Venue
Journal of Energy Storage
Publisher
Elsevier BV
Published
2018-12
Volume
20
Pages
497-519
ISSN
2352-152X (ISSN-L)
OpenAlex
W2898624949
Cited by
269
References
163
FWCI
13.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.