Novel methodology of cardiac health recognition based on ECG signals and evolutionary-neural system
Open accessThe DOI matches its Crossref record; 99 of the 99 references it cites were found in a registry or an index.
Abstract
New methodology based on single lead and analysis of longer (10-s) ECG signal fragments is proposed.New training based on genetic algorithm coupled with 10-fold cross-validation is employed.17 classes: normal sinus rhythm + pacemaker rhythm + 15 cardiac disorders are recognized.New feature extraction and selection based on PSD, DFT and GA are employed.Recognition sensitivity at a level of 90.20% (98 errors per 1000 classifications) is promising. This article presents an innovative research methodology that enables the efficient classification of cardiac disorders (17 classes) based on ECG signal analysis and an evolutionary-neural system.From a social point of view, it is extremely important to prevent heart diseases, which are the most common cause of death worldwide. According to statistical data, 50 million people are at risk for cardiac diseases worldwide. The subject of ECG signal analysis is very popular. However, due to the great difficulty of the task undertaken, and high computational complexity of existing methods, there remains substantial work to perform.This research collected 1000 fragments of ECG signals from the MIH-BIH Arrhythmia database for one lead, MLII, from 45 patients. An original methodology that consisted of the analysis of longer (10-s) fragments of the ECG signal was used (an average of 13 times less classifications). To enhance the characteristic features of the ECG signal, the spectral power density was estimated (using Welchs method and a discrete Fourier transform). Genetic optimization of parameters and genetic selection of features were tested. Pre-processing, normalization, feature extraction and selection, cross-validation and machine learning algorithms (SVM, kNN, PNN, and RBFNN) were used.The best evolutionary-neural system, based on the SVM classifier, obtained a recognition sensitivity of 17 myocardium dysfunctions at a level of 90.20% (98 errors per 1000 classifications, accuracy = 98.85%, specificity = 99.39%, time for classification of one sample = 0.0023 [s]). Against the background of the current scientific literature, these results are some of the best results to date.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortes, C., & Vapnik, V. (1995) · Machine Learning · doi:10.1007/bf00994018 · Cited by 59,421
Holland, J. H. (1992) · The MIT Press eBooks · doi:10.7551/mitpress/1090.001.0001 · Cited by 47,002
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Book Review: Pattern Recognition and Machine Learning
Nasrabadi, N. M. (2007) · Journal of Electronic Imaging · doi:10.1117/1.2819119 · Cited by 22,066
An introduction to ROC analysis
Fawcett, T. (2006) · Pattern Recognition Letters · doi:10.1016/j.patrec.2005.10.010 · Cited by 21,879
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Welch, P. (1967) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1967.1161901 · Cited by 12,277
Learning with Kernels: Support Vector Machines, Regularization, Optimization, and Beyond
Schölkopf, B., & Smola, A. J. (2001) · The MIT Press eBooks · doi:10.7551/mitpress/4175.001.0001 · Cited by 11,703
Pattern Recognition and Machine Learning
(2006) · doi:10.1007/978-0-387-45528-0 · Cited by 9,824
Global status report on noncommunicable diseases 2010.
Alwan, A. (2011) · Cited by 8,494
Cited by
Arrhythmia detection using deep convolutional neural network with long duration ECG signals
Yıldırım, Ö., Pławiak, P., Tan, R.-S., & Acharya, U. R. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.09.009 · Cited by 851
Self-citationYildirim, Ö. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.03.016 · Cited by 833
ECG Arrhythmia Classification Using STFT-Based Spectrogram and Convolutional Neural Network
Huang, J., Chen, B., Yao, B., & He, W. (2019) · IEEE Access · doi:10.1109/access.2019.2928017 · Cited by 591
Classification of myocardial infarction with multi-lead ECG signals and deep CNN
Baloglu, U. B., Talo, M., Yildirim, O., Tan, R. S., & Acharya, U. R. (2019) · Pattern Recognition Letters · doi:10.1016/j.patrec.2019.02.016 · Cited by 473
A deep learning approach for real-time detection of atrial fibrillation
Andersen, R. S., Peimankar, A., & Puthusserypady, S. (2019) · Expert Systems with Applications · doi:10.1016/j.eswa.2018.08.011 · Cited by 402
A new approach for arrhythmia classification using deep coded features and LSTM networks
Yildirim, O., Baloglu, U. B., Tan, R.-S., Ciaccio, E. J., & Acharya, U. R. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.05.004 · Cited by 386
A new machine learning technique for an accurate diagnosis of coronary artery disease
Abdar, M., Książek, W., Acharya, U. R., Tan, R.-S., Makarenkov, V., & Pławiak, P. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.104992 · Cited by 342
Self-citationA systematic survey of computer-aided diagnosis in medicine: Past and present developments
Yanase, J., & Triantaphyllou, E. (2019) · Expert Systems with Applications · doi:10.1016/j.eswa.2019.112821 · Cited by 303
“Furthermore, the T wave peaks in an ECG are completed right before a period of diastole starts.”
BackgroundInfluentialMachine learning-based coronary artery disease diagnosis: A comprehensive review
Alizadehsani, R., Abdar, M., Roshanzamir, M., Khosravi, A., Kebria, P. M., Khozeimeh, F., Nahavandi, S., Sarrafzadegan, N., & Acharya, U. R. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.103346 · Cited by 273
Pławiak, P., & Acharya, U. R. (2020) · Neural Computing and Applications · doi:10.1007/s00521-018-03980-2 · Cited by 248
Self-citationRetractedYang, W., Si, Y., Wang, D., & Guo, B. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.08.003 · Cited by 171
A comprehensive review of AI-Based detection of Arrhythmia using Electrocardiogram (ECG)
Ayyub, A., Politis, C., & Usman, M. A. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110594 · Cited by 18
A Bayesian Hierarchical Network for Combining Heterogeneous Data Sources in Medical Diagnoses
Donnat, C., Miolane, N., Bunbury, F., & Kreindler, J. (2020) · arXiv · doi:10.48550/arxiv.2007.13847 · Cited by 7
Metadata
- Authors
- Pławiak, P.
- Venue
- Expert Systems with Applications
- Publisher
- Elsevier BV
- Published
- 2018-02
- Volume
- 92
- Pages
- 334-349
- ISSN
- 0957-4174 (ISSN-L)
- OpenAlex
- W2755507768
- Cited by
- 264
- References
- 99
- FWCI
- 18.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.