In situ crosslinked electrospun gelatin nanofibers for skin regeneration
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Abstract Due to its intrinsic similarity to the extracellular matrix, gelatin electrospun nanofibrous meshes are promising scaffold structures for wound dressings and tissue engineering applications. However, gelatin is water soluble and presents poor mechanical properties, which generally constitute relevant limitations to its applicability. In this work, gelatin was in situ crosslinked with 1,4-butanediol diglycidyl ether (BDDGE) at different concentrations (2, 4 and 6 wt%) and incubation time-points (24, 48 and 72 h) at 37 °C. The physico-chemical and biological properties of BDDGE-crosslinked electrospun gelatin meshes were investigated. Results show that by changing the BDDGE concentration it is possible to produce nanofibers crosslinked in situ with well-defined morphology and modulate fiber size and mechanical properties. Crosslinked gelatin meshes show no toxicity towards fibroblasts, stimulating their adhesion, proliferation and synthesis of new extracellular matrix, thereby indicating the potential of this strategy for skin tissue engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomaterials & scaffolds for tissue engineering
O'Brien, F. J. (2011) · Materials Today · doi:10.1016/s1369-7021(11)70058-x · Cited by 3,437
Cited by
Electrospinning for tissue engineering applications
Rahmati, M., Mills, D. K., Urbanska, A. M., Saeb, M. R., Venugopal, J. R., Ramakrishna, S., & Mozafari, M. (2021) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100721 · Cited by 816
Electrospun Polycaprolactone (PCL) Degradation: An In Vitro and In Vivo Study
Dias, J. R., Sousa, A., Augusto, A., Bártolo, P. J., & Granja, P. L. (2022) · Polymers · doi:10.3390/polym14163397 · Cited by 293
Self-citationCross-Linking Strategies for Electrospun Gelatin Scaffolds
Campiglio, C. E., Contessi Negrini, N., Farè, S., & Draghi, L. (2019) · Materials · doi:10.3390/ma12152476 · Cited by 277
Rodríguez-Rodríguez, R., Espinosa-Andrews, H., Velasquillo-Martínez, C., & García-Carvajal, Z. Y. (2020) · International Journal of Polymeric Materials and Polymeric Biomaterials · doi:10.1080/00914037.2019.1581780 · Cited by 268
Li, T., Sun, M., & Wu, S. (2022) · Nanomaterials · doi:10.3390/nano12050784 · Cited by 262
Electrospinning based on benign solvents: current definitions, implications and strategies
Avossa, J., Herwig, G., Toncelli, C., Itel, F., & Rossi, R. M. (2022) · Green Chemistry · doi:10.1039/d1gc04252a · Cited by 233
Natural polymers in wound healing: From academic studies to commercial products
Tavakoli, M., Labbaf, S., Mirhaj, M., Salehi, S., Seifalian, A. M., & Firuzeh, M. (2023) · Journal of Applied Polymer Science · doi:10.1002/app.53910 · Cited by 74
Stretchable silk fibroin hydrogels
Oral, C. B., Yetiskin, B., & Okay, O. (2020) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2020.08.040 · Cited by 35
Metadata
- Authors
- Dias, J. R., Baptista-Silva, S., Oliveira, C. M. T. D., Sousa, A., Oliveira, A. L., Bártolo, P. J., & Granja, P. L.
- Venue
- European Polymer Journal
- Publisher
- Elsevier BV
- Published
- 2017-10
- Volume
- 95
- Pages
- 161-173
- ISSN
- 0014-3057 (ISSN-L)
- OpenAlex
- W2744071334
- Cited by
- 100
- References
- 1
- FWCI
- 2.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.