Biomedical applications of polyethylene
Open accessThe DOI matches its Crossref record; 111 of the 111 references it cites were found in a registry or an index.
Abstract
Polyethylene has many advantages as a biomaterial for medical implants and has been extensively applied to the fabrication of porous high-density polyethylene implant for facial and cranial reconstruction. Here we review the properties of polyethylene and its applicability to biomedical applications, including the material properties and influence on processing and surface treatments relevant to surgical implants. Following this, we describe the evolution and reporting of polyethylene’s clinical use, as commercial products as reported in scientific research literature. Recent publications and commercial activities are now focussing on incorporating patient-specific design and surgical planning to improve clinical outcomes. This article highlights how the current research landscape is moving into a new era of personalised medicine and optimised tissue regeneration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Porosity of 3D biomaterial scaffolds and osteogenesis
Karageorgiou, V., & Kaplan, D. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.002 · Cited by 6,622
The return of a forgotten polymer—Polycaprolactone in the 21st century
Woodruff, M. A., & Hutmacher, D. W. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.04.002 · Cited by 4,033
Self-citationPorous scaffold design for tissue engineering
Hollister, S. J. (2005) · Nature Materials · doi:10.1038/nmat1421 · Cited by 3,969
Chen, Q., & Thouas, G. A. (2015) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.10.001 · Cited by 2,398
25th Anniversary Article: Engineering Hydrogels for Biofabrication
Malda, J., Visser, J., Melchels, F. P., Jüngst, T., Hennink, W. E., Dhert, W. J. A., Groll, J., & Hutmacher, D. W. (2013) · Advanced Materials · doi:10.1002/adma.201302042 · Cited by 1,901
Fused deposition modeling of novel scaffold architectures for tissue engineering applications
Zein, I., Hutmacher, D. W., Tan, K. C., & Teoh, S. H. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00232-0 · Cited by 1,874
Polymeric Scaffolds in Tissue Engineering Application: A Review
Dhandayuthapani, B., Yoshida, Y., Maekawa, T., & Kumar, D. S. (2011) · International Journal of Polymer Science · doi:10.1155/2011/290602 · Cited by 1,773
Bone tissue engineering using polycaprolactone scaffolds fabricated via selective laser sintering
Williams, J. M., Adewunmi, A., Schek, R. M., Flanagan, C. L., Krebsbach, P. H., Feinberg, S. E., Hollister, S. J., & Das, S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.057 · Cited by 1,563
Hutmacher, D. W., Schantz, T., Zein, I., Ng, K. W., Teoh, S. H., & Tan, K. C. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200105)55:2<203::aid-jbm1007>3.0.co;2-7 · Cited by 1,409
3D bioactive composite scaffolds for bone tissue engineering
Turnbull, G., Clarke, J., Picard, F., Riches, P., Jia, L., Han, F., Li, B., & Shu, W. (2018) · Bioactive Materials · doi:10.1016/j.bioactmat.2017.10.001 · Cited by 1,332
Cited by
Biomedical Applications of Titanium Alloys: A Comprehensive Review
Marin, E., & Lanzutti, A. (2023) · Materials · doi:10.3390/ma17010114 · Cited by 489
Microplastics in human blood: Polymer types, concentrations and characterisation using μFTIR
V. L. Leonard, S., Liddle, C. R., Atherall, C. A., Chapman, E., Watkins, M., D. J. Calaminus, S., & Rotchell, J. M. (2024) · Environment International · doi:10.1016/j.envint.2024.108751 · Cited by 284
Al-Shalawi, F. D., Mohamed Ariff, A. H., Jung, D.-W., Mohd Ariffin, M. K. A., Seng Kim, C. L., Brabazon, D., & Al-Osaimi, M. O. (2023) · Polymers · doi:10.3390/polym15122601 · Cited by 235
Joseph, B., James, J., Kalarikkal, N., & Thomas, S. (2021) · Advanced Industrial and Engineering Polymer Research · doi:10.1016/j.aiepr.2021.06.003 · Cited by 195
Microplastics and human health: Integrating pharmacokinetics
Prata, J. C. (2023) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2023.2195798 · Cited by 193
“Moreover, biomedical applications of synthetic materials, such as the use of high-density polyethylene in bone grafts, are at the forefront of medicine and require more research (Paxton et al., 2019).”
BackgroundArrington, A. S., Brown, J. R., Win, M. S., Winey, K. I., & Long, T. E. (2022) · Polymer Chemistry · doi:10.1039/d2py00394e · Cited by 28
Metadata
- Authors
- Paxton, N. C., Allenby, M. C., Lewis, P. M., & Woodruff, M. A.
- Venue
- European Polymer Journal
- Publisher
- Elsevier BV
- Published
- 2019-09
- Volume
- 118
- Pages
- 412-428
- ISSN
- 0014-3057 (ISSN-L)
- OpenAlex
- W2946083445
- Cited by
- 215
- References
- 111
- FWCI
- 5.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.