The DOI matches its Crossref record.
Electrophysiological assessment of retinal ganglion cell function
Open accessAbstract
The function of retinal ganglion cells (RGCs) can be non-invasively assessed in experimental and genetic models of glaucoma by means of variants of the ERG technique that emphasize the activity of inner retina neurons. The best understood technique is the Pattern Electroretinogram (PERG) in response to contrast-reversing gratings or checkerboards, which selectively depends on the presence of functional RGCs. In glaucoma models, the PERG can be altered before histological loss of RGCs; PERG alterations may be either reversed with moderate IOP lowering or exacerbated with moderate IOP elevation. Under particular luminance-stimulus conditions, the Flash-ERG displays components that may reflect electrical activity originating in the proximal retina and be altered in some experimental glaucoma models (positive Scotopic Threshold response, pSTR; negative Scotopic Threshold Response, nSTR; Photopic Negative Response, PhNR; Oscillatory Potentials, OPs; multifocal ERG, mfERG). It is not yet known which of these components is most sensitive to glaucomatous damage. Electrophysiological assessment of RGC function appears to be a necessary outcome measure in experimental glaucoma models, which complements structural assessment and may even predict it. Neuroprotective strategies could be tested based on enhancement of baseline electrophysiological function that results in improved RGC survival. The use of electrophysiology in glaucoma models may be facilitated by specifically designed instruments that allow high throughput, robust assessment of electrophysiological function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optic nerve astrocyte reactivity protects function in experimental glaucoma and other nerve injuries
Sun, D., Moore, S., & Jakobs, T. C. (2017) · Journal of Experimental Medicine · doi:10.1084/jem.20160412 · Cited by 130
Electroretinography in glaucoma diagnosis
Wilsey, L. J., & Fortune, B. (2016) · Current Opinion in Ophthalmology · doi:10.1097/icu.0000000000000241 · Cited by 113
Rocha, L. R., Nguyen Huu, V. A., Palomino La Torre, C., Xu, Q., Jabari, M., Krawczyk, M., Weinreb, R. N., & Skowronska‐Krawczyk, D. (2020) · Aging Cell · doi:10.1111/acel.13089 · Cited by 68
Chou, T.-H., Romano, G. L., Amato, R., & Porciatti, V. (2020) · Nutrients · doi:10.3390/nu12071910 · Cited by 57
Self-citationOptineurin-facilitated axonal mitochondria delivery promotes neuroprotection and axon regeneration
Liu, D., Webber, H. C., Bian, F., Xu, Y., Prakash, M., Feng, X., Yang, M., Yang, H., You, I.-J., Li, L., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-57135-8 · Cited by 34
σ2R/TMEM97 in retinal ganglion cell degeneration
Wang, H., Peng, Z., Li, Y., Sahn, J. J., Hodges, T. R., Chou, T.-H., Liu, Q., Zhou, X., Jiao, S., Porciatti, V., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-24537-3 · Cited by 13
Self-citation(2019) · doi:10.1101/684811 · Cited by 4
Metadata
- Authors
- Porciatti, V.
- Venue
- Experimental Eye Research
- Publisher
- Elsevier BV
- Published
- 2015-12
- Volume
- 141
- Pages
- 164-170
- ISSN
- 0014-4835 (ISSN-L)
- OpenAlex
- W2045338875
- Cited by
- 191
- References
- 0
- FWCI
- 11.58
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.