CoChat

Role of endoscopic functional luminal imaging probe in predicting the outcome of gastric peroral endoscopic pyloromyotomy (with video)

Vosoughi, Kia, Ichkhanian, Yervant, Jacques, Jérémie, Aadam, A. Aziz, Benias, Petros C., Law, Ryan, Hasler, William L., Canakis, Andrew, Ragi, Olivier, Triggs, Joseph, Bowers, Nicole, Brewer Gutierrez, Olaya I., Kumbhari, Vivek, Kalloo, Anthony N., Bulat, Robert S., Pandolfino, John E., Khashab, Mouen A. · 2020 · Gastrointestinal Endoscopy
Cited by 97

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND AND AIMS Endoluminal functional luminal imaging probe (EndoFLIP) is an imaging tool that measures physiological characteristics of gastrointestinal sphincters. In this study we used EndoFLIP to evaluate the association between the pyloric physiological measurements with clinical outcomes of gastric peroral endoscopic myotomy (G-POEM) in patients with refractory gastroparesis. METHODS Thirty-seven patients who underwent G-POEM for management of refractory gastroparesis and had EndoFLIP measurements from five centers were evaluated. Cross-sectional area (CSA), balloon pressure (BP), and distensibility index (DI) of the pylorus were evaluated by EndoFLIP at 40 mL and 50 mL balloon fills before and after G-POEM. One-year clinical success and change in gastric emptying study (GES) 3 months after the G-POEM procedure were compared with EndoFLIP measurements. RESULTS Clinical success was achieved in 26 (70%) patients. Post-G-POEM CSA and DI were significantly higher in the clinical success group with both 40 mL (CSA: 89.9 ± 64.8 vs 172.5 ± 71.9 mm2, p=0.003; DI: 5.8 ± 4.4 vs 8.8 ± 6.1 mm2/mm Hg, p=0.043) and 50 mL volume distention (CSA: 140.1 ± 89.9 vs 237.5 ± 80.3 mm2, p=0.003; DI: 5.6 ± 3.3 vs 9.9 ± 6.6 mm2/mm Hg, p=0.049). CSA using 40 mL volume distention, with an area under the curve (AUC) of 0.83 yielded specificity of 91% and sensitivity of 71% at a cut-off point of 154 mm2. CONCLUSIONS Post-G-POEM CSA of the pylorus associates with clinical success and improvement of GES after G-POEM. EndoFLIP measurements of pylorus have the potential to be used as a predicting tool of the G-POEM clinical outcome.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.gie.2020.01.044

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Vosoughi, K., Ichkhanian, Y., Jacques, J., Aadam, A. A., Benias, P. C., Law, R., Hasler, W. L., Canakis, A., Ragi, O., Triggs, J., Bowers, N., Brewer Gutierrez, O. I., Kumbhari, V., Kalloo, A. N., Bulat, R. S., Pandolfino, J. E., & Khashab, M. A.
Venue
Gastrointestinal Endoscopy
Publisher
Elsevier BV
Published
2020-06
Volume
91
Issue
6
Pages
1289-1299
ISSN
0016-5107 (ISSN-L)
OpenAlex
W3004543614
Cited by
97
References
2
FWCI
10.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.