Accuracy of artificial intelligence on histology prediction and detection of colorectal polyps: a systematic review and meta-analysis
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND AIMS We perform a meta-analysis of all published studies to determine the diagnostic accuracy of AI on histology prediction and detection of colorectal polyps. METHOD We searched Embase, PubMed, Medline, Web of Science and Cochrane library databases to identify studies using AI for colorectal polyp histology prediction and detection. The quality of the included studies was measured by the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. We used a bivariate meta-analysis following a random effects model to summarize the data and plotted hierarchical summary receiver-operating characteristic (HSROC) curves. The area under the HSROC curve (AUC) served as an indicator of the diagnostic accuracy and during head-to-head comparison. RESULT A total of 7,680 images of colorectal polyps from 18 studies were included in the analysis of histology prediction. The accuracy of the AI (AUC) was 0.96 (95% CI, 0.95-0.98), with corresponding pooled sensitivity of 92.3% (95% CI, 88.8%-94.9%) and specificity of 89.8% (95% CI, 85.3%-93.0%). The AUC of AI using narrow-band imaging (NBI) was significantly higher than non-NBI (0.98 vs 0.84, p<0.01). The performance of AI was superior to nonexpert endoscopists (0.97 vs 0.90, p<0.01). For characterization of diminutive polyps using deep learning model with non-magnifying NBI, the pooled negative predictive value was 95.1% (95% CI, 87.7%-98.1%). For polyp detection, the pooled AUC was 0.90 (95% CI, 0.67-1.00) with sensitivity of 95.0% (95% CI, 91.0%-97.0%) and specificity of 88.0% (95% CI, 58.0%-99.0%). CONCLUSION AI was accurate in histology prediction and detection of colorectal polyps, including diminutive polyps. The performance of AI was better under NBI and was superior to non-expert endoscopists. Despite the difference in AI models and study designs, the AI performances are rather consistent, which could serve a reference for future AI studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.06.006 · Cited by 10,578
Wang, P., Berzin, T. M., Glissen Brown, J. R., Bharadwaj, S., Becq, A., Xiao, X., Liu, P., Li, L., Song, Y., Zhang, D., et al. (2019) · Gut · doi:10.1136/gutjnl-2018-317500 · Cited by 865
Byrne, M. F., Chapados, N., Soudan, F., Oertel, C., Linares Pérez, M., Kelly, R., Iqbal, N., Chandelier, F., & Rex, D. K. (2019) · Gut · doi:10.1136/gutjnl-2017-314547 · Cited by 635
Rex, D. K., Kahi, C., O'Brien, M., Levin, T. R., Pohl, H., Rastogi, A., Burgart, L., Imperiale, T., Ladabaum, U., Cohen, J., et al. (2011) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2011.01.023 · Cited by 629
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W., Westwood, M. E., Mallett, S. V., Deeks, J. J., Reitsma, J. B., Leeflang, M., Sterne, J. A. C., & Bossuyt, P. M. (2011) · Data Archiving and Networked Services (DANS) · doi:10.1059/0003-4819-155-8-201110180-00009 · Cited by 601
Mori, Y., Kudo, S.-E., Misawa, M., Saito, Y., Ikematsu, H., Hotta, K., Ohtsuka, K., Urushibara, F., Kataoka, S., Ogawa, Y., et al. (2018) · Annals of Internal Medicine · doi:10.7326/m18-0249 · Cited by 509
Abu Dayyeh, B. K., Thosani, N., Konda, V., Wallace, M. B., Rex, D. K., Chauhan, S. S., Hwang, J. H., Komanduri, S., Manfredi, M., Maple, J. T., et al. (2015) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2014.12.022 · Cited by 389
Cited by
Gut microbiome, big data and machine learning to promote precision medicine for cancer
Cammarota, G., Ianiro, G., Ahern, A., Carbone, C., Temko, A., Claesson, M. J., Gasbarrini, A., & Tortora, G. (2020) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-020-0327-3 · Cited by 324
Impact of artificial intelligence on miss rate of colorectal neoplasia
Wallace, M. B., Sharma, P., Bhandari, P., East, J., Antonelli, G., Lorenzetti, R., Vieth, M., Speranza, I., Spadaccini, M., Desai, M., et al. (2022) · Gastroenterology · doi:10.1053/j.gastro.2022.03.007 · Cited by 273
Artificial Intelligence in Colorectal Cancer Screening, Diagnosis and Treatment. A New Era
Mitsala, A., Tsalikidis, C., Pitiakoudis, M., Simopoulos, C., & Tsaroucha, A. K. (2021) · Current Oncology · doi:10.3390/curroncol28030149 · Cited by 271
Artificial intelligence assists precision medicine in cancer treatment
Liao, J., Li, X., Gan, Y., Han, S., Rong, P., Wang, W., Li, W., & Zhou, L. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2022.998222 · Cited by 256
Artificial intelligence and colonoscopy experience: lessons from two randomised trials
Repici, A., Spadaccini, M., Antonelli, G., Correale, L., Maselli, R., Galtieri, P. A., Pellegatta, G., Capogreco, A., Milluzzo, S. M., Lollo, G., et al. (2022) · Gut · doi:10.1136/gutjnl-2021-324471 · Cited by 248
Jayakumar, S., Sounderajah, V., Normahani, P., Harling, L., Markar, S. R., Ashrafian, H., & Darzi, A. (2022) · npj Digital Medicine · doi:10.1038/s41746-021-00544-y · Cited by 110
Computer-aided detection-assisted colonoscopy: classification and relevance of false positives
Hassan, C., Badalamenti, M., Maselli, R., Correale, L., Iannone, A., Radaelli, F., Rondonotti, E., Ferrara, E., Spadaccini, M., Alkandari, A., et al. (2020) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2020.06.021 · Cited by 81
Huang, D., Shen, J., Hong, J., Zhang, Y., Dai, S., Du, N., Zhang, M., & Guo, D. (2022) · International Journal of Colorectal Disease · doi:10.1007/s00384-021-04062-x · Cited by 64
Li, J. W., Wu, C. C. H., Lee, J. W. J., Liang, R., Soon, G. S. T., Wang, L. M., Koh, X. H., Koh, C. J., Chew, W. D., Lin, K. W., et al. (2023) · American Journal of Gastroenterology · doi:10.14309/ajg.0000000000002282 · Cited by 61
Guerrero Vinsard, D., Fetzer, J. R., Agrawal, U., Singh, J., Damani, D. N., Sivasubramaniam, P., Poigai Arunachalam, S., Leggett, C. L., Raffals, L. E., & Coelho-Prabhu, N. (2023) · iGIE · doi:10.1016/j.igie.2023.03.004 · Cited by 43
Metadata
- Authors
- Lui, T. K. L., Guo, C.-G., & Leung, W. K.
- Venue
- Gastrointestinal Endoscopy
- Publisher
- Elsevier BV
- Published
- 2020-07
- Volume
- 92
- Issue
- 1
- Pages
- 11-22.e6
- ISSN
- 0016-5107 (ISSN-L)
- OpenAlex
- W3007551936
- Cited by
- 122
- References
- 8
- FWCI
- 2.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.