Extended high frequency hearing and speech perception implications in adults and children
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Extended high frequencies (EHF), above 8 kHz, represent a region of the human hearing spectrum that is generally ignored by clinicians and researchers alike. This article is a compilation of contributions that, together, make the case for an essential role of EHF in both normal hearing and auditory dysfunction. We start with the fundamentals of biological and acoustic determinism - humans have EHF hearing for a purpose, for example, the detection of prey, predators, and mates. EHF hearing may also provide a boost to speech perception in challenging conditions and its loss, conversely, might help explain difficulty with the same task. However, it could be that EHF are a marker for damage in the conventional frequency region that is more related to speech perception difficulties. Measurement of EHF hearing in concert with otoacoustic emissions could provide an early warning of age-related hearing loss. In early life, when EHF hearing sensitivity is optimal, we can use it for enhanced phonetic identification during language learning, but we are also susceptible to diseases that can prematurely damage it. EHF audiometry techniques and standardization are reviewed, providing evidence that they are reliable to measure and provide important information for early detection, monitoring and possible prevention of hearing loss in populations at-risk. To better understand the full contribution of EHF to human hearing, clinicians and researchers can contribute by including its measurement, along with measures of speech in noise and self-report of hearing difficulties and tinnitus in clinical evaluations and studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Derivation of auditory filter shapes from notched-noise data
Glasberg, B. R., & Moore, B. C. J. (1990) · Hearing Research · doi:10.1016/0378-5955(90)90170-t · Cited by 2,423 · cited 1×
“The aging auditory system in humans has commonly been characterized by the gradual decline in behavioral hearing thresholds (Gordon-Salant, 2005).”
BackgroundThe Speech, Spatial and Qualities of Hearing Scale (SSQ)
Gatehouse, S., & Noble, W. (2004) · International Journal of Audiology · doi:10.1080/14992020400050014 · Cited by 1,385 · cited 1×
“Using a more physiologically or perceptually relevant binning approach with third-octave bands or equivalent rectangular bandwidths (ERB; Glasberg and Moore, 1990) reveals that averaged speech energy beyond 8 kHz may be only 10e20 dB lower in level than energy at lower frequencies (Fig.”
BackgroundFactors Governing the Intelligibility of Speech Sounds
French, N. R., & Steinberg, J. C. (1947) · The Journal of the Acoustical Society of America · doi:10.1121/1.1916407 · Cited by 1,131 · cited 2×
“…recognition–that the contribution of any given spectral region to speech recognition is determined entirely by the audibility within that region (French and Steinberg, 1947) According to the LF-through-EHF hypothesis, hearing loss in the EHF range reduces the transmission of speech…”
BackgroundSchaette, R., & McAlpine, D. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.2156-11.2011 · Cited by 1,009 · cited 2×
“of “hidden hearing loss” (Kujawa and Liberman, 2019; Schaette and McAlpine, 2011) in that it can occur in conjunction with normal pure-tone audiometry in the standard frequency range ! 8 kHz; (Badri et al.”
BackgroundKujawa, S. G., & Liberman, M. C. (2015) · Hearing Research · doi:10.1016/j.heares.2015.02.009 · Cited by 754 · cited 1×
“Finally, the possibility of age-related synaptopathy in the cochlea could complicate the relationship between hearing thresholds and OAE levels by altering the efferent control of OAEs but, at least initially, not influencing hearing thresholds (Kujawa and Liberman, 2015).”
BackgroundHearing ranges of laboratory animals.
Heffner, H. E., & Heffner, R. S. (2007) · PubMed · Cited by 695
Toward a Differential Diagnosis of Hidden Hearing Loss in Humans
Liberman, M. C., Epstein, M. J., Cleveland, S. S., Wang, H., & Maison, S. F. (2016) · PLOS ONE · doi:10.1371/journal.pone.0162726 · Cited by 639
Sound Texture Perception via Statistics of the Auditory Periphery: Evidence from Sound Synthesis
McDermott, J. H., & Simoncelli, E. P. (2011) · Neuron · doi:10.1016/j.neuron.2011.06.032 · Cited by 403
The Perception of Speech and Its Relation to Telephony
Fletcher, H., & Galt, R. H. (1950) · The Journal of the Acoustical Society of America · doi:10.1121/1.1906605 · Cited by 360
Stelmachowicz, P. G., Pittman, A. L., Hoover, B. M., Lewis, D. E., & Moeller, M. P. (2004) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.130.5.556 · Cited by 335
Cited by
Assessment and Management of Platinum-Related Ototoxicity in Children Treated for Cancer
Romano, A., Capozza, M. A., Mastrangelo, S., Maurizi, P., Triarico, S., Rolesi, R., Attinà, G., Fetoni, A. R., & Ruggiero, A. (2020) · Cancers · doi:10.3390/cancers12051266 · Cited by 65
“Because early auditory damage can condition the normal development of language [66], the use of high frequency audiometry has an important role in the pediatric age.”
BackgroundIliadou, E., Bitzios, V., Pastiadis, K., Plack, C. J., & Bibas, A. (2024) · Noise and Health · doi:10.4103/nah.nah_41_23 · Cited by 3
Metadata
- Authors
- Hunter, L. L., Monson, B. B., Moore, D. R., Dhar, S., Wright, B. A., Munro, K. J., Zadeh, L. M., Blankenship, C. M., Stiepan, S. M., & Siegel, J. H.
- Venue
- Hearing Research
- Publisher
- Elsevier BV
- Published
- 2020-11
- Volume
- 397
- Pages
- 107922
- ISSN
- 0378-5955 (ISSN-L)
- OpenAlex
- W3006967799
- Cited by
- 183
- References
- 48
- FWCI
- 6.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.