Thermogelling properties of purified poloxamer 407
Open accessAbstract
Poloxamers are triblock copolymers with a center block of hydrophobic polypropylene oxide (PPO) flanked by two hydrophilic polyethyleneoxide (PEO) blocks. Among this family of copolymers, poloxamer 407 is a non-ionic surfactant with reversible gelation properties above a particular polymer concentration and a particular temperature. Easy preparation of poloxamer 407 based sterile injectable formulations have made this copolymer a good candidate for drug delivery, specifically when controlled release of the drug is required. Previously, the applications of compendial poloxamer 407 preparations were demonstrated; however, low viscosity, poor elasticity, and sol-to-gel transition temperature (T sol-gel ) over a wide temperature range were observed. A purification process was introduced to eliminate impurities and low molecular weight copolymer molecules from the compendial poloxamer 407 resulting in higher viscosity values with T sol-gel in a narrow temperature range. Here, poloxamer 407 was purified based on the proposed process and the rheological and analytical evaluation of the purified poloxamer 407 was conducted and compared to unpurified, compendial poloxamer 407. Then, the impact of poloxamer 407 concentration on gel formation was evaluated. For drug delivery applications, the effect of relevant buffer salts and the effect of addition of ethanol to the poloxamer 407 solutions were rheologically evaluated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pluronic® block copolymers as novel polymer therapeutics for drug and gene delivery
Kabanov, A. V., Batrakova, E. V., & Alakhov, V. Y. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00009-3 · Cited by 1,474
A Review of Poloxamer 407 Pharmaceutical and Pharmacological Characteristics
Dumortier, G., Grossiord, J. L., Agnely, F., & Chaumeil, J. C. (2006) · Pharmaceutical Research · doi:10.1007/s11095-006-9104-4 · Cited by 1,261
Fakhari, A., & Berkland, C. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.03.005 · Cited by 518
Self-citationSelf-assembling materials for therapeutic delivery
Branco, M. C., & Schneider, J. P. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2008.09.018 · Cited by 462
Recent progress in biomedical applications of pluronic (PF127): Pharmaceutical perspectives
Akash, M. S. H., & Rehman, K. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.04.032 · Cited by 394
Sustained release of lidocaine from Poloxamer 407 gels
Ricci, E. J., Lunardi, L. O., Nanclares, D. M. A., & Marchetti, J. M. (2005) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2004.09.028 · Cited by 261
Almeida, H., Amaral, M. H., Lobão, P., & Lobo, J. M. S. (2014) · Drug Discovery Today · doi:10.1016/j.drudis.2013.10.001 · Cited by 257
Micellisation and gelation of triblock copoly(oxyethylene/oxypropylene/oxyethylene), F127
Yu, G.-E., Deng, Y., Dalton, S., Wang, Q.-G., Attwood, D., Price, C., & Booth, C. (1992) · Journal of the Chemical Society, Faraday Transactions · doi:10.1039/ft9928802537 · Cited by 200
Engineered in-situ depot-forming hydrogels for intratumoral drug delivery
Fakhari, A., & Anand Subramony, J. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.11.014 · Cited by 164
Self-citationA Highly Active, Isospecific Cobalt Catalyst for Propylene Oxide Polymerization
Peretti, K. L., Ajiro, H., Cohen, C. T., Lobkovsky, E. B., & Coates, G. W. (2005) · Journal of the American Chemical Society · doi:10.1021/ja053451y · Cited by 139
Metadata
- Authors
- Fakhari, A., Corcoran, M., & Schwarz, A.
- Venue
- Heliyon
- Publisher
- Elsevier BV
- Published
- 2017-08
- Volume
- 3
- Issue
- 8
- Pages
- e00390
- ISSN
- 2405-8440 (ISSN-L)
- OpenAlex
- W2752014220
- Cited by
- 272
- References
- 19
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thermogelling properties of purified poloxamer 407. https://app.cochat.ai/papers/10.1016/j.heliyon.2017.e00390
- The paper
- Fakhari, A., Corcoran, M., & Schwarz, A. (2017). Thermogelling properties of purified poloxamer 407. Heliyon. https://doi.org/10.1016/j.heliyon.2017.e00390
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.