Miniaturized Reveal LINQ insertable cardiac monitoring system: First-in-human experience
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The Reveal LINQ is a miniaturized insertable cardiac monitor (ICM) with wireless telemetry for remote monitoring of patients with suspected arrhythmias. OBJECTIVE: The primary objective of this study was to evaluate the functionality of the Reveal LINQ system by measuring R-wave sensing and data transmission. METHODS: The Reveal LINQ Usability Study was a nonrandomized, prospective, multicenter trial. The study enrolled 30 patients with any indication for an ICM. Data were collected at baseline, implantation, and 1-month follow-up visits and through daily wireless transmissions. RESULTS: Thirty patients were enrolled and had a Reveal LINQ device implanted. The mean age was 55 ± 15 years. All patients had successful implantation of the ICM in one of the recommended locations. Ease of implantation procedure was rated as easy or very easy for 90% of implantations. R-wave amplitudes were 0.584 ± 0.325 mV at implantation and 0.596 ± 0.336 mV at 1 month (P = .8). Automatic transmissions were successful 79.5% (69.5%-86.9%) of the time. Transmission failures that caused a delay in data transfer occurred because of incomplete data reception or patients being out of range in 45% and 42% of instances, respectively. For all patients, transmission failures were followed by successful automated or manual transmission of information on a subsequent day. The devices stored 217 arrhythmic episodes during 30 days of follow-up, identified as atrial fibrillation (n = 111), asystole (n = 95), bradycardia (n = 4), fast ventricular tachycardia (n = 1), and ventricular tachycardia ( n = 6). No serious procedure- or system-related adverse events occurred during the 1-month follow-up period. CONCLUSION: The miniaturized Reveal LINQ ICM supports arrhythmia detection and monitoring, achieving adequate sensing performance without safety issues. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01965899.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100 · cited 1×
“0 25th–75th percentile 0–0 Minimum–maximum 0–10 Angular rotation relative to original device implant orientation, n (%) 01 27 (90) 01–251 3 (10) Longitudinal axis rotation relative to original device implant orientation, n (%) 01 28 (93) 901 2 (7)”
Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879
Krahn, A. D., Klein, G. J., Yee, R., & Skanes, A. C. (2001) · Circulation · doi:10.1161/01.cir.104.1.46 · Cited by 405
Indications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362 · cited 1×
“We report positive results with regard to (1) ease of implantation, (2) quality of ECGs obtained, (3) remote monitoring as assessed by daily transmissions, (4) absence of major complications, and (5) no significant device migration after a follow-up of 1 month.”
Use of an Extended Monitoring Strategy in Patients With Problematic Syncope
Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C. (1999) · Circulation · doi:10.1161/01.cir.99.3.406 · Cited by 360
Cost implications of testing strategy in patients with syncope
Krahn, A. D., Klein, G. J., Yee, R., Hoch, J. S., & Skanes, A. C. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00659-4 · Cited by 170
Cited by
PULSE‐SMART: Pulse‐Based Arrhythmia Discrimination Using a Novel Smartphone Application
McMANUS, D. D., CHONG, J. W., SONI, A., SACZYNSKI, J. S., ESA, N., NAPOLITANO, C., DARLING, C. E., BOYER, E., ROSEN, R. K., FLOYD, K. C., et al. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12842 · Cited by 156
Ambulatory cardiac bio-signals: From mirage to clinical reality through a decade of progress
Periyaswamy, T., & Balasubramanian, M. (2019) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2019.07.007 · Cited by 14
Veltmann, C., Bosch, R., Boer, J., Endres, M., Frankenstein, L., Gröschel, K., Hansen, C., & Straube, F. (2023) · Die Kardiologie · doi:10.1007/s12181-023-00634-z · Cited by 3
Metadata
- Authors
- Pürerfellner, H., Sanders, P., Pokushalov, E., Di Bacco, M., Bergemann, T., & Dekker, L. R. C.
- Venue
- Heart Rhythm
- Publisher
- Elsevier BV
- Published
- 2015-06
- Volume
- 12
- Issue
- 6
- Pages
- 1113-1119
- ISSN
- 1547-5271 (ISSN-L)
- OpenAlex
- W2092025629
- Cited by
- 96
- References
- 7
- FWCI
- 9.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.